• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7BD7 OP 77B
    Awaiting product image

    Siemens 6AV6355-1CA47-7BD7 OP 77B

    € 1.704,44

    Reset
    Clear
    SKU: 6AV6355-1CA47-7BD7 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7BD7 is an operator panel belonging to the OP 77B series within the Siemens SIMATIC HMI product family. This compact panel operator device is designed for machine-level human-machine interface applications, providing a text-based display for process visualization and operator control. It is part of the SIMATIC HMI Basic Panels generation and is manufactured by Siemens AG under the SIMATIC HMI portfolio.

    The OP 77B features a monochrome STN LCD display capable of showing multiple lines of text and simple graphics, with a membrane keypad for operator input including function keys and system keys. It supports MPI and PROFIBUS DP communication interfaces for direct integration with Siemens S7-200, S7-300, and S7-400 PLCs, as well as connections to third-party controllers via serial interfaces. The panel is configured using Siemens WinCC flexible software and offers recipe management, alarm logging, and trend display capabilities within its onboard memory.

    The OP 77B is widely used in manufacturing automation, machine building, and process control applications where a cost-effective, robust operator interface is required at the machine level. It is suitable for industries such as packaging, food and beverage, automotive assembly, and general factory automation. Its compact form factor and compatibility with the SIMATIC S7 controller family make it a practical choice for retrofitting older installations or equipping new machines with a reliable HMI solution.

    Technical Specifications

    Display Type Monochrome STN LCD
    Display Size 4 lines of text
    Input/Operating Voltage 24 V DC
    Communication Interface MPI, PROFIBUS DP, RS-422/485
    Operating Temperature 0 °C to 50 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 10 % to 90 %, non-condensing
    IP Protection Rating (Front) IP65
    IP Protection Rating (Rear) IP20
    Mounting Panel mounting
    Configuration Software WinCC flexible 2008 or higher
    Series/Product Family SIMATIC HMI OP 77B
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC controller.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the HMI project configuration and that the PLC is in RUN mode.
    Event ID: 10001
    Connection to the configured PLC has been interrupted or cannot be established.
    Inspect the communication cable for damage. Confirm bus address and baud rate settings in the HMI project match the PLC configuration. Check that the PLC is powered and operational.
    Event ID: 20000
    Project download error — the project transfer to the panel has failed or been interrupted.
    Verify the transfer cable connection and PC communication settings. Ensure WinCC flexible is set to the correct transfer mode and that the panel is in transfer mode before initiating download.
    Event ID: 40000
    Tag read/write error — the HMI cannot read from or write to a configured PLC tag.
    Check that the PLC data block or memory address referenced in the HMI project exists and is accessible. Verify data type compatibility between the HMI tag and the PLC variable.
    Event ID: 70010
    Internal device error — a hardware or firmware fault has been detected on the panel.
    Perform a panel restart by cycling the 24 V DC supply. If the error persists, perform a factory reset and re-download the project. Contact Siemens technical support if the fault remains.
    Event ID: 50000
    Recipe data error — recipe records cannot be read or written correctly.
    Check available panel memory. Verify recipe configuration in WinCC flexible for correct tag assignments and data types. Clear corrupted recipe data and re-download the project if necessary.
    Event ID: 60000
    Alarm buffer overflow — the number of pending alarms exceeds the buffer capacity.
    Acknowledge and clear active alarms on the panel. Review the alarm configuration in WinCC flexible to reduce unnecessary alarm triggers or increase the alarm buffer size within project settings.

    Frequently Asked Questions

    Which PLCs are compatible with the Siemens OP 77B (6AV6355-1CA47-7BD7)?

    The OP 77B is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP. It also supports connections to third-party controllers using RS-422/485 serial communication with appropriate drivers configured in WinCC flexible.

    What software is required to configure and program the OP 77B panel?

    The OP 77B is configured using Siemens WinCC flexible 2008 or a compatible version. Projects are transferred to the panel via the MPI interface or a dedicated PC/PPI cable depending on the communication setup.

    What is the supply voltage for the 6AV6355-1CA47-7BD7?

    The panel operates on a 24 V DC supply voltage. Ensure the power supply is within the specified tolerance range to guarantee reliable operation.

    What is the front panel protection rating of the OP 77B?

    The front panel of the OP 77B carries an IP65 protection rating, making it suitable for installation in control cabinet doors where it may be exposed to dust and water spray.

    Can the OP 77B display graphical content or only text?

    The OP 77B is primarily a text-based operator panel with a monochrome STN LCD. It can display simple bar graphs and trend views in addition to text, but it is not designed for full graphical visualization as found in touch-screen HMI panels.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the panel power connector. Check for correct polarity. Inspect the internal fuse if accessible.

    Ensure the 24 V DC supply is within tolerance and correctly wired. If the supply is confirmed good and the display remains blank, the internal power supply or display backlight may have failed, requiring panel repair or replacement.

    Panel cannot communicate with the S7 PLC

    Verify the MPI or PROFIBUS DP cable is correctly connected and terminated at both ends. Check that the bus address configured in the HMI project matches the address set on the PLC. Use a bus diagnostic tool to check for bus errors.

    Replace or reseat the communication cable. Correct any address mismatches in the WinCC flexible project and re-download. Ensure termination resistors are active only at the physical ends of the bus segment.

    Project transfer from PC to panel fails repeatedly

    Confirm the panel is set to transfer mode before initiating the download. Check the PC communication port settings and cable integrity. Verify that the WinCC flexible project version is compatible with the panel firmware version.

    Restart both the panel and the PC, set the panel to transfer mode, and retry the download. If the issue persists, update the panel firmware to the version required by the WinCC flexible project and attempt the transfer again.

    Function keys do not respond or respond incorrectly

    Check whether the issue is consistent across all function keys or limited to specific keys. Inspect the membrane keypad for physical damage, contamination, or deformation.

    Clean the keypad surface carefully. If individual keys are unresponsive due to membrane damage, the keypad membrane assembly requires replacement. For software-related key assignment issues, review and correct the key configuration in the WinCC flexible project.

    Alarms are displayed but cannot be acknowledged

    Check the alarm configuration in WinCC flexible to confirm that an acknowledgement button or key has been correctly assigned. Verify that the corresponding PLC bit for alarm acknowledgement is being written correctly by the HMI.

    Correct the acknowledgement key assignment in the project and re-download. Ensure the PLC logic is correctly processing the acknowledgement bit sent from the HMI panel.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart