• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1AA47-7FA0 OP 77A
    Awaiting product image

    Siemens 6AV6355-1AA47-7FA0 OP 77A

    € 1.014,03

    Reset
    Clear
    SKU: 6AV6355-1AA47-7FA0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1AA47-7FA0 is an operator panel belonging to the OP 77A series, part of the SIMATIC HMI product line. This compact panel is designed for machine-level operator control and monitoring tasks, offering a text-based display interface for straightforward process visualization. It is a Siemens product intended for integration into industrial control systems where a cost-effective and reliable HMI solution is required.

    The OP 77A features a multi-line text display capable of showing process values, alarms, and operator prompts. It supports MPI and PROFIBUS DP communication interfaces, enabling direct connection to SIMATIC S7 PLCs. The unit operates on a 24 V DC supply and is built to withstand the demands of industrial environments, with a front panel protection rating suitable for panel mounting. Configuration is performed using Siemens WinCC flexible software.

    The OP 77A is commonly deployed in manufacturing, machine building, and process automation applications where operators require a simple interface for parameter entry, status monitoring, and alarm acknowledgment. It is well suited for integration with SIMATIC S7-200, S7-300, and S7-400 controller families. Typical installations include conveyor systems, packaging machinery, and general-purpose industrial machines requiring a compact and cost-effective operator interface.

    Technical Specifications

    Display Type STN LCD, text-based
    Display Lines 4 lines
    Characters per Line 20 characters
    Input/Operating Voltage 24 V DC
    Power Consumption Approx. 4 W
    Communication Interface MPI, PROFIBUS DP
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10 % to 90 %, non-condensing
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL
    Configuration Software WinCC flexible 2005 or higher
    Series/Product Family SIMATIC HMI OP 77A

    Common Error Codes and System Events

    Event ID: 10000
    Communication error between the OP 77A and the connected PLC. The panel cannot establish or maintain a connection to the controller.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the configuration in WinCC flexible. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Connection to the configured PLC has been interrupted during operation.
    Inspect communication cables for damage or loose connectors. Verify bus termination and cable shielding. Restart the panel and PLC if the connection is not restored automatically.
    Event ID: 20000
    Project download error. The configuration project could not be transferred to the panel successfully.
    Verify the PC-to-panel connection cable is correctly seated. Ensure WinCC flexible version is compatible with the panel firmware. Retry the download after restarting both the panel and the configuration PC.
    Event ID: 40000
    System memory error. The panel has detected an issue with internal memory during startup or operation.
    Perform a factory reset of the panel and re-download the project. If the error persists, the internal memory may be faulty and the unit should be sent for repair or replacement.
    Event ID: 50000
    Firmware version mismatch. The firmware on the panel is not compatible with the downloaded project.
    Update the panel firmware to the version required by the WinCC flexible project. Use the Siemens ProSave tool or WinCC flexible to perform the firmware update.
    Event ID: 60000
    Configuration error detected at startup. The panel cannot load the stored project due to a corrupted or missing configuration.
    Re-download the project from WinCC flexible to the panel. Verify the project file integrity on the configuration PC before transferring.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77A?

    The OP 77A is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with certain SIMATIC S5 controllers depending on configuration.

    What software is required to configure the OP 77A?

    The OP 77A is configured using Siemens WinCC flexible 2005 or a later compatible version. Projects are created on a PC and downloaded to the panel via a PC/PPI or MPI cable.

    What is the supply voltage for the 6AV6355-1AA47-7FA0?

    The panel requires a 24 V DC supply voltage for operation.

    What is the front panel protection rating of the OP 77A?

    The front panel of the OP 77A carries an IP65 protection rating, making it suitable for panel-mount installations where dust and water spray protection is required.

    Can the OP 77A display graphics or only text?

    The OP 77A is a text-based operator panel and does not support graphical display. It is designed for alphanumeric text output, alarm messages, and parameter entry.

    Troubleshooting

    Display remains blank after power on

    Check that 24 V DC supply voltage is present at the power connector. Measure voltage at the panel terminals to confirm correct polarity and adequate current supply.

    Ensure the power supply provides stable 24 V DC within the specified tolerance. Replace the power supply or check wiring if voltage is absent or out of range. If voltage is correct, the internal power circuitry may be faulty and the unit may require repair.

    Panel shows communication error and cannot connect to PLC

    Verify the MPI or PROFIBUS DP address configured in the WinCC flexible project matches the address set on the PLC. Check physical cable connections and bus termination at both ends of the network.

    Correct any address mismatches in the project configuration and re-download to the panel. Replace or reseat communication cables. Ensure bus termination resistors are enabled only at the two physical ends of the bus segment.

    Project download fails or times out

    Confirm the correct download cable type is being used and that the cable driver is properly installed on the PC. Check that the panel is in transfer mode before initiating the download.

    Place the panel in transfer mode via the panel menu. Reinstall the PC adapter driver if necessary. Retry the download using WinCC flexible, ensuring no firewall or antivirus software is blocking the communication port.

    Alarm messages are not displayed correctly or are missing

    Review the alarm configuration in the WinCC flexible project to confirm alarm tags are correctly linked to PLC data addresses. Verify the PLC program is writing the expected values to the alarm trigger bits.

    Correct any tag address mismatches in the WinCC flexible project and re-download the configuration. Test alarm triggering from the PLC side to confirm the correct bits are being set.

    Panel restarts repeatedly or enters a boot loop

    A corrupted project file or firmware issue may be causing the panel to fail during startup. Attempt to enter the panel's service menu during boot to access diagnostic options.

    Perform a factory reset using the ProSave tool connected via the serial interface. Re-download a verified project file and, if necessary, update the panel firmware to the latest compatible version.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart