Siemens 6AV6355-1AA47-7ER0 OP 77A
€ 428,93
The Siemens 6AV6355-1AA47-7ER0 is an operator panel belonging to the SIMATIC HMI OP 77A series, manufactured by Siemens. It is a compact, key-operated panel designed for human-machine interface applications in industrial automation environments. The OP 77A provides a straightforward interface for machine operators to monitor process values and control equipment without the complexity of a full graphical touchscreen system.
The OP 77A features a monochrome LCD display and a membrane keypad for operator input, offering reliable tactile feedback in demanding industrial conditions. It supports the MPI (Multi-Point Interface) and PROFIBUS DP communication protocols, enabling direct integration with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel is configured using Siemens WinCC flexible software and supports recipe management, alarm logging, and trend display functions. It operates on a 24 V DC supply and is rated to IP65 on the front face, providing protection against dust and water ingress.
The OP 77A is commonly deployed in machine building, manufacturing automation, and process control applications where a cost-effective, robust operator interface is required. It is well suited for use on packaging machines, conveyor systems, and general-purpose industrial machinery where operators need to adjust setpoints, acknowledge alarms, and monitor process variables. Its compact form factor and panel-mount design make it appropriate for integration into control cabinets and machine enclosures with limited front-panel space.
Technical Specifications
| Display Type | Monochrome LCD |
|---|---|
| Display Size | 4 lines x 20 characters |
| Input/Operating Voltage | 24 V DC |
| Communication Interface | MPI, PROFIBUS DP |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10 % to 90 % (non-condensing) |
| Mounting | Panel mount |
| Configuration Software | WinCC flexible |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between the OP 77A and the connected PLC. The panel cannot establish or maintain a connection to the controller.
Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the panel configuration in WinCC flexible. Ensure the PLC is powered and in RUN mode. - Event ID: 10001
- Timeout error on the communication link. The panel did not receive a response from the PLC within the expected time window.
Check for cable faults or excessive cable length. Verify baud rate settings are consistent across all devices on the bus. Reduce bus load if multiple devices are connected. - Event ID: 20000
- Configuration or project download error. The project loaded on the panel is incompatible or corrupt.
Re-download the project from WinCC flexible to the panel. Verify the project was compiled without errors before transfer. Check that the WinCC flexible version is compatible with the panel firmware version. - Event ID: 40000
- Tag acquisition error. One or more process tags cannot be read from the PLC.
Verify the PLC data block addresses referenced in the WinCC flexible project exist and are accessible. Check that the PLC program is running and the relevant data areas are not write-protected. - Event ID: 50000
- Alarm buffer overflow. The number of pending alarms has exceeded the panel's alarm buffer capacity.
Acknowledge and clear active alarms on the panel. Review the alarm configuration in WinCC flexible to reduce unnecessary alarm triggers. Consider increasing the alarm buffer size in the project settings if supported. - System Fault
- Internal panel hardware fault detected. The panel has identified an internal error during self-diagnostics.
Perform a power cycle on the panel. If the fault persists, perform a factory reset and re-download the project. If the issue continues, the panel may require repair or replacement.
Frequently Asked Questions
Which PLCs are compatible with the OP 77A?
The OP 77A is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP communication interfaces.
What software is used to configure the OP 77A?
The OP 77A is configured using Siemens WinCC flexible. The project is compiled in WinCC flexible and downloaded to the panel via the MPI or PROFIBUS DP interface.
What is the supply voltage for the 6AV6355-1AA47-7ER0?
The panel operates on a 24 V DC supply voltage.
What is the front panel protection rating of the OP 77A?
The front face of the OP 77A is rated to IP65, providing protection against dust and low-pressure water jets.
Does the OP 77A support recipe management and alarm logging?
Yes, the OP 77A supports recipe management, alarm logging, and trend display functions as part of its standard feature set when configured through WinCC flexible.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the panel power connector. Verify the supply is within the specified tolerance range. Inspect the power connector for loose or corroded contacts.
Ensure the 24 V DC supply is stable and within specification. Re-seat the power connector. If the display remains blank with confirmed correct supply voltage, the internal power supply or display unit may be faulty and the panel should be sent for repair.
Panel displays communication error and cannot connect to PLC
Inspect the MPI or PROFIBUS DP cable for physical damage, correct termination, and secure connections at both the panel and PLC ends. Verify the bus address configured on the panel matches the WinCC flexible project settings.
Replace or re-terminate the communication cable if damaged. Correct the bus address settings in WinCC flexible and re-download the project. Ensure termination resistors are enabled only at the two physical ends of the bus.
Project download from WinCC flexible fails
Check the USB or MPI cable connection between the programming PC and the panel. Verify the WinCC flexible software version is compatible with the panel firmware. Check that the panel is in transfer mode.
Place the panel in transfer mode via the panel's start screen. Use a known-good MPI cable. Update WinCC flexible or the panel firmware if a version mismatch is identified. Retry the download.
Keypad buttons are unresponsive or intermittently responsive
Inspect the membrane keypad for physical damage, contamination, or deformation. Check if the issue is isolated to specific keys or affects all keys.
Clean the keypad surface with a dry cloth to remove contamination. If specific keys are physically damaged or the membrane is torn, the keypad membrane assembly should be replaced. If all keys are unresponsive, check the internal ribbon cable connection between the keypad and the main board.
Alarms are not displayed or acknowledged on the panel
Verify the alarm configuration in the WinCC flexible project, including the PLC tag addresses linked to alarm triggers. Check that the PLC program is writing the correct values to the alarm trigger tags.
Correct any misconfigured alarm tag addresses in WinCC flexible and re-download the project. Confirm the PLC logic is functioning as intended by monitoring the alarm trigger tags online. Ensure the alarm buffer is not full, which would prevent new alarms from being displayed.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page