Siemens 6AV6355-1AA47-7EL0 OP 77A
€ 236,38
The Siemens 6AV6355-1AA47-7EL0 is an operator panel belonging to the OP 77A series, part of the SIMATIC HMI Basic Panels product family manufactured by Siemens. This compact operator panel is designed for machine-level human-machine interface applications, providing operators with a straightforward interface for monitoring and controlling automated processes. It features a monochrome display and a membrane keypad for reliable input in industrial environments.
The OP 77A panel is equipped with a 4-line STN LCD display capable of showing text and simple graphics, with a resolution of 160 x 80 pixels. It communicates via MPI and PROFIBUS DP interfaces, enabling direct integration with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs. The unit operates on a 24 V DC supply and is configured using Siemens WinCC flexible software. The front panel carries an IP65 protection rating, making it resistant to dust and water jets in demanding industrial settings.
The OP 77A is widely used in manufacturing, packaging, material handling, and process automation applications where a cost-effective, reliable operator interface is required at the machine level. Its compact form factor and robust membrane keypad make it suitable for installation in control cabinets and machine panels where space is limited. The panel is particularly common in applications already utilizing Siemens SIMATIC S7 controllers, where seamless communication and configuration are priorities.
Technical Specifications
| Display Type | STN LCD, monochrome |
|---|---|
| Display Resolution | 160 x 80 pixels |
| Display Lines | 4 lines of text |
| Input/Operating Voltage | 24 V DC |
| Communication Interface | MPI, PROFIBUS DP |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| Configuration Software | WinCC flexible 2005 or higher |
| Mounting | Panel mounting |
| Certifications | CE, UL |
| Series/Product Family | SIMATIC HMI OP 77A |
Common Error Codes and System Events
- Event ID: 10000
- Configuration error detected on startup; the loaded project is incompatible with the panel firmware version.
Reload the project using a compatible version of WinCC flexible and ensure the firmware is up to date. - Event ID: 20000
- Communication error on MPI/PROFIBUS DP interface; the panel cannot establish a connection to the configured PLC.
Check MPI/PROFIBUS cable connections, verify bus termination resistors are correctly placed, and confirm the PLC address settings match the project configuration. - Event ID: 40000
- Project download failed; transfer was interrupted or the project file is corrupt.
Restart the transfer process, verify the communication cable integrity, and ensure sufficient memory is available on the panel. - Event ID: 50000
- Tag read/write error; the panel is unable to read or write a configured tag from the connected controller.
Verify the tag address in WinCC flexible matches the actual PLC data block or memory address. Check PLC program for address conflicts. - Event ID: 60000
- System memory low; available memory on the panel is insufficient to run the current project.
Reduce the project size by removing unused screens, tags, or graphics. Consider archiving historical data if applicable. - Event ID: 70000
- Watchdog timeout; the panel application has stopped responding within the expected time frame.
Perform a controlled restart of the panel. If the fault persists, reload the project or check for excessive screen complexity causing processing overload. - Event ID: 80000
- Power supply undervoltage detected; the 24 V DC supply has dropped below the minimum operating threshold.
Measure the supply voltage at the panel terminals. Ensure the power supply unit is rated correctly and check for voltage drops due to cable resistance or load issues.
Frequently Asked Questions
Which PLCs are compatible with the OP 77A panel?
The OP 77A is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP communication interfaces.
What software is used to configure the Siemens 6AV6355-1AA47-7EL0?
The panel is configured using Siemens WinCC flexible 2005 or a later compatible version of the software.
What is the front panel protection rating of the OP 77A?
The front panel of the OP 77A carries an IP65 protection rating, making it suitable for environments with dust and water spray exposure.
What is the supply voltage required for this panel?
The OP 77A requires a 24 V DC power supply for operation.
Can the OP 77A display graphics or only text?
The OP 77A can display simple graphics as well as text on its 160 x 80 pixel monochrome STN LCD display, though it is primarily optimized for text-based operator interfaces.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the panel power terminals using a multimeter. Verify the power supply output is within the acceptable range.
Ensure the supply voltage is stable at 24 V DC. Replace the power supply if the voltage is out of range. If the supply is correct, the internal power board may require inspection or replacement.
Panel shows communication error and cannot connect to PLC
Verify the MPI or PROFIBUS DP cable is correctly connected and undamaged. Check bus termination at both ends of the network and confirm the panel and PLC addresses are correctly configured in the project.
Replace or reseat the communication cable, correct bus termination, and ensure the PLC address in WinCC flexible matches the physical PLC configuration. Restart both the panel and PLC after making changes.
Project download fails or transfer is interrupted
Check the transfer cable connection between the PC and the panel. Confirm the panel is in transfer mode and that the correct communication port and settings are selected in WinCC flexible.
Restart the panel in transfer mode, verify the cable integrity, and retry the download. If the issue persists, try a different USB or serial cable and ensure no firewall or antivirus software is blocking the transfer.
Keypad buttons are unresponsive or intermittently fail
Inspect the membrane keypad for physical damage, contamination, or wear. Check the internal ribbon cable connection between the keypad and the main board.
Clean the keypad surface with a dry cloth. If individual keys are consistently unresponsive, the membrane keypad assembly should be replaced. Reseat the ribbon cable connector if accessible during servicing.
Panel restarts unexpectedly during operation
Monitor the 24 V DC supply for voltage dips or instability under load. Check the ambient temperature around the panel to ensure it is within the 0 to 50 degrees Celsius operating range.
Stabilize the power supply by using a dedicated, correctly rated unit. Improve ventilation around the panel if overheating is suspected. If restarts continue, reload the project to rule out software corruption.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page