• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1AA47-7EK0 OP 177B
    Awaiting product image

    Siemens 6AV6355-1AA47-7EK0 OP 177B

    € 1.722,53

    Reset
    Clear
    SKU: 6AV6355-1AA47-7EK0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1AA47-7EK0 is an Operator Panel (OP 177B) belonging to the SIMATIC HMI series, designed for machine-level human-machine interface applications. This unit provides a monochrome or color display interface for process visualization, operator control, and status monitoring in industrial environments. As part of the SIMATIC HMI comfort and mobile panel lineage, it integrates directly with Siemens SIMATIC S7 controllers and third-party PLCs via standard communication protocols.

    The OP 177B features a 5.7-inch STN display with a resolution of 320 x 240 pixels and supports both MPI/PROFIBUS DP and Ethernet (PROFINET) communication interfaces, enabling flexible integration into existing automation networks. The panel is configured using WinCC flexible engineering software and supports function keys for operator input alongside a membrane keypad. It offers onboard flash memory for project storage and operates on a 24 V DC supply, with a protection rating suitable for front-panel installation in control cabinets.

    The OP 177B is widely deployed in manufacturing, process automation, and machine building industries where a compact, robust operator interface is required. It is commonly found on packaging machinery, conveyor systems, and general-purpose industrial machines where operators need to monitor process values, acknowledge alarms, and adjust setpoints. Its compatibility with the SIMATIC S7-300 and S7-400 controller families makes it a standard choice for Siemens-based automation architectures.

    Technical Specifications

    Display Size 5.7 inch
    Display Type STN LCD
    Display Resolution 320 x 240 pixels (QVGA)
    Display Colors 256 colors
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 9 W
    Communication Interface MPI/PROFIBUS DP, Ethernet (PROFINET)
    Configuration Software WinCC flexible 2008 or later
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC HMI OP 177B

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC. The panel cannot establish or maintain a connection to the controller.
    Check MPI/PROFIBUS DP or Ethernet cable connections. Verify the PLC address and communication parameters configured in WinCC flexible match the controller settings. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Connection to the configured PLC was interrupted during runtime operation.
    Inspect physical communication cables for damage. Check network topology and termination resistors on PROFIBUS segments. Restart both the HMI panel and the PLC if the connection does not recover automatically.
    Event ID: 20000
    Project download error. The project could not be transferred to the HMI panel successfully.
    Verify the transfer cable or network connection between the engineering PC and the panel. Ensure WinCC flexible version is compatible with the panel firmware. Check available flash memory on the device.
    Event ID: 40000
    Internal device error or hardware fault detected on the operator panel.
    Perform a power cycle on the device. If the error persists, check for firmware corruption and attempt a firmware update via WinCC flexible. Contact Siemens technical support or arrange for panel repair/replacement if the fault remains.
    Event ID: 50000
    Alarm buffer overflow. The number of pending alarms has exceeded the panel's alarm buffer capacity.
    Acknowledge and clear existing alarms in the alarm view. Review the alarm configuration in WinCC flexible to reduce unnecessary alarm triggers or increase the alarm buffer size in the project settings.
    Event ID: 70000
    Tag update error. One or more configured tags cannot be read from or written to the PLC.
    Verify PLC tag addresses in the WinCC flexible project match the actual PLC data block or memory addresses. Check that the PLC program is running and the relevant data areas are accessible.
    Event ID: 80000
    System memory low warning. Available runtime memory on the HMI panel is critically low.
    Reduce the number of active screens, animations, or logged data in the project. Archive or clear historical data logs stored on the device. Consider optimizing the WinCC flexible project to reduce memory usage.

    Frequently Asked Questions

    What communication interfaces does the OP 177B (6AV6355-1AA47-7EK0) support?

    The OP 177B supports MPI, PROFIBUS DP, and Ethernet (PROFINET) communication interfaces, allowing connection to SIMATIC S7-200, S7-300, and S7-400 PLCs as well as third-party controllers via these protocols.

    Which engineering software is required to configure this HMI panel?

    The OP 177B is configured using Siemens WinCC flexible 2008 or a compatible later version. Projects are created on a PC and downloaded to the panel via Ethernet or MPI/PROFIBUS connection.

    What is the supply voltage for the 6AV6355-1AA47-7EK0?

    The panel operates on a 24 V DC supply voltage. Ensure a stable, regulated 24 V DC power source is used to avoid operational issues.

    What is the front panel protection rating of the OP 177B?

    The front panel of the OP 177B carries an IP65 protection rating, making it suitable for installation in environments where dust and water spray may be present.

    Is the OP 177B compatible with SIMATIC S7-1200 or S7-1500 controllers?

    The OP 177B has limited compatibility with S7-1200 and S7-1500 controllers and is primarily designed for use with S7-300 and S7-400 families. For S7-1200/1500 projects, Siemens recommends using newer SIMATIC HMI panels configured with TIA Portal.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the panel's power connector. Check that the supply is within the specified tolerance. Inspect the internal fuse if accessible.

    Restore the 24 V DC supply to the correct level. If the supply is correct and the display remains blank, the backlight or internal power supply board may have failed and the unit should be sent for repair or replacement.

    HMI panel fails to communicate with the PLC

    Verify the physical connection of the MPI, PROFIBUS DP, or Ethernet cable. Check the communication parameters (station address, baud rate, IP address) configured in the WinCC flexible project against the PLC settings.

    Correct any mismatched communication parameters in WinCC flexible and re-download the project. Replace damaged cables and ensure PROFIBUS termination resistors are correctly placed at both ends of the bus segment.

    Touchscreen or function keys not responding

    Check whether the panel is in transfer mode, which disables normal operation. Inspect the keypad membrane for physical damage or contamination.

    Exit transfer mode by cycling power or pressing the appropriate key combination. If keys are physically damaged or unresponsive after cleaning, the membrane keypad assembly requires replacement.

    Project cannot be downloaded to the panel

    Confirm the panel is in transfer mode and the correct communication interface is selected in WinCC flexible. Check that the PC and panel are connected via the appropriate cable or network.

    Set the panel to transfer mode via the Start Center menu. Ensure the WinCC flexible project settings match the panel type and firmware version. Update panel firmware if a version mismatch is detected.

    Alarms are not displayed or acknowledged on the panel

    Check the alarm configuration in WinCC flexible, including the PLC bit addresses assigned to alarm triggers. Verify that the PLC is setting the correct alarm bits and that the panel is communicating with the PLC.

    Correct the alarm tag addresses in the WinCC flexible project to match the PLC program. Re-download the project and test alarm triggering from the PLC side to confirm correct operation.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart