• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1AA47-7DL3 OP 77A
    Awaiting product image

    Siemens 6AV6355-1AA47-7DL3 OP 77A

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6355-1AA47-7DL3 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1AA47-7DL3 is an operator panel belonging to the SIMATIC HMI OP 77A series, manufactured by Siemens as part of its SIMATIC HMI product line. This compact panel operator unit is designed for machine-level human-machine interface applications, providing a straightforward interface for process visualization and operator control. It is a key component in Siemens' portfolio of basic HMI devices intended for integration into control cabinets and machine panels.

    The OP 77A features a monochrome STN LCD display with a resolution of 160 x 80 pixels, offering clear text and simple graphic display capabilities. It is equipped with a membrane keypad for operator input, including function keys and system keys for navigation and control. The unit supports MPI and PROFIBUS DP communication interfaces for direct connection to Siemens SIMATIC S7 PLCs, and it operates on a 24 V DC supply voltage. Configuration is performed using Siemens WinCC flexible software, enabling straightforward project engineering.

    The OP 77A is widely used in manufacturing, machine building, and process automation environments where a cost-effective, reliable operator interface is required at the machine level. It is particularly suited for applications in packaging machinery, conveyor systems, and general-purpose industrial machinery where basic process monitoring and operator input are needed. Its compact form factor and robust membrane keypad make it appropriate for installation in space-constrained control panels subject to industrial environments.

    Technical Specifications

    Display Type Monochrome STN LCD
    Display Resolution 160 x 80 pixels
    Display Colors Monochrome (blue/white)
    Input Voltage 24 V DC
    Voltage Tolerance 19.2 V DC to 28.8 V DC
    Communication Interface MPI, PROFIBUS DP
    Configuration Software WinCC flexible 2005 or higher
    Input Type Membrane keypad
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC HMI OP 77A

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the OP 77A and the connected PLC. The panel cannot establish or maintain a connection to the configured controller.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the project configuration. Ensure the PLC is in RUN mode.
    Event ID: 10001
    Connection to the PLC was interrupted during operation.
    Inspect communication cables for damage or loose connectors. Check bus termination and cable shielding. Restart the panel and PLC if the connection is not re-established automatically.
    Event ID: 20000
    Project download error. Transfer of the configuration project to the panel failed.
    Verify the transfer cable connection and PC interface settings. Ensure WinCC flexible is configured with the correct transfer parameters and that the panel is in transfer mode.
    Event ID: 40000
    Internal device error detected during self-test or operation.
    Perform a panel restart. If the error persists, perform a factory reset and re-download the project. Contact Siemens technical support if the fault recurs.
    Event ID: 50000
    Configuration or project error. The loaded project contains settings incompatible with the device type or firmware version.
    Check the WinCC flexible project for correct device type selection. Update the panel firmware if necessary and re-download the project.
    Event ID: 70000
    Firmware update error. The firmware update process was interrupted or failed.
    Repeat the firmware update procedure using the correct firmware file for the OP 77A. Ensure stable power supply during the update process.
    Event ID: 30000
    Tag or variable access error. A configured tag cannot be read from or written to the PLC.
    Verify the PLC data block and variable addresses in the WinCC flexible project. Ensure the PLC program contains the referenced data areas and that the PLC is in RUN mode.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77A?

    The OP 77A is designed for use with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with S7-200 via PPI protocol.

    What software is required to configure the 6AV6355-1AA47-7DL3?

    The OP 77A is configured using Siemens WinCC flexible 2005 or a later version. The project is transferred to the panel via a PC adapter cable connected to the MPI interface.

    What is the supply voltage for this operator panel?

    The OP 77A operates on a 24 V DC supply voltage, with an acceptable range of 19.2 V DC to 28.8 V DC.

    What is the IP protection rating of the OP 77A?

    The front face of the OP 77A is rated IP65, providing protection against dust and water jets. The rear of the unit is rated IP20.

    Can the OP 77A display graphics and images?

    The OP 77A supports basic graphics display on its monochrome STN LCD. It can display simple bitmaps and line graphics, but is primarily suited for text-based process visualization rather than complex graphical interfaces.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power connector using a multimeter. Verify the voltage is within the 19.2 V to 28.8 V range. Inspect the power cable and connector for damage.

    Restore the correct supply voltage if out of range. Replace damaged power cables or connectors. If voltage is correct and display remains blank, the internal power supply or display unit may be faulty and require repair or replacement.

    Panel shows 'No connection to PLC' or communication error on screen

    Inspect the MPI or PROFIBUS DP cable for physical damage, loose connectors, or incorrect termination. Verify the bus address configured in the project matches the panel and PLC settings.

    Replace or reseat the communication cable. Correct bus termination by ensuring terminating resistors are active only at the two physical ends of the bus. Adjust the PLC or panel address in the project configuration if there is a mismatch.

    Project transfer from PC to panel fails

    Confirm the panel is set to transfer mode by navigating to the transfer settings in the panel's start center. Check the PC adapter cable connection and verify the correct COM port and transfer speed are selected in WinCC flexible.

    Set the panel to transfer mode, select the correct interface settings in WinCC flexible, and retry the transfer. Replace the PC adapter cable if communication cannot be established.

    Function keys do not respond or produce incorrect actions

    Check the project configuration in WinCC flexible to verify that function key assignments are correctly defined. Test individual keys to determine if the issue is isolated to specific keys or affects all keys.

    Correct any incorrect key assignments in the WinCC flexible project and re-download to the panel. If keys are physically unresponsive, the membrane keypad may be worn or damaged and require replacement.

    Panel repeatedly restarts or enters an error loop after startup

    Attempt to access the panel's start center during boot by pressing the appropriate key combination. Check if the loaded project is compatible with the installed firmware version.

    Perform a factory reset via the start center to clear the existing project. Update the firmware to the version compatible with the WinCC flexible project, then re-download the project. If restarts continue, the internal hardware may require service.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart