• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1AA47-7DD0 OP 77A
    Awaiting product image

    Siemens 6AV6355-1AA47-7DD0 OP 77A

    € 955,52

    Reset
    Clear
    SKU: 6AV6355-1AA47-7DD0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1AA47-7DD0 is an operator panel belonging to the SIMATIC HMI OP 77A series, designed for machine-level human-machine interface applications. This compact panel provides a keypad-based interface for monitoring and controlling industrial processes and is part of Siemens' SIMATIC HMI product line. It is intended for use as a local operator station in automation environments where a robust, panel-mounted interface is required.

    The OP 77A features a monochrome LCD display and a membrane keypad with function keys, system keys, and numeric entry capability. It communicates via MPI and PROFIBUS DP interfaces, enabling direct integration with SIMATIC S7-200, S7-300, and S7-400 PLCs. The unit operates on 24 V DC supply voltage and is configured using WinCC flexible software. Its compact housing is designed for front-panel mounting with an IP65 protection rating on the front face.

    The 6AV6355-1AA47-7DD0 is typically deployed in machine building, manufacturing automation, and process control applications where a cost-effective, keypad-operated HMI is sufficient. It is well-suited for controlling conveyor systems, packaging machinery, and general-purpose machine tools. Its compatibility with the SIMATIC S7 controller family makes it a practical choice for facilities already standardized on Siemens automation infrastructure.

    Technical Specifications

    Display Type Monochrome LCD
    Display Size 4 lines x 20 characters
    Input/Operating Voltage 24 V DC
    Communication Interface MPI, PROFIBUS DP
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Mounting Panel mounting
    Configuration Software WinCC flexible 2005 or higher
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the OP 77A and the connected PLC. The panel cannot establish or maintain a connection to the controller.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the configuration in WinCC flexible. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Connection to the PLC was interrupted during operation.
    Inspect the communication cable for damage or loose connectors. Check bus termination and cable shielding. Restart the panel and PLC if the connection does not recover automatically.
    Event ID: 20000
    Configuration download error. The project data could not be transferred to the panel correctly.
    Verify the WinCC flexible project is compiled without errors. Check the transfer cable or network connection between the engineering PC and the panel. Retry the download.
    Event ID: 40000
    System memory low. Available memory for runtime operation is insufficient.
    Reduce the size of the loaded project by removing unused screens or tags. Ensure no unnecessary background tasks are running. Consider upgrading to a panel with greater memory capacity if the project cannot be reduced.
    Event ID: 50000
    Operating system error or internal system fault detected on the panel.
    Perform a panel restart. If the fault persists, perform a factory reset and reload the project. If the issue continues, the panel may require service or replacement.
    Event ID: 60000
    Power supply voltage out of range. The 24 V DC supply voltage is below or above the permitted tolerance.
    Measure the supply voltage at the panel power connector. Ensure the supply is within the specified 24 V DC tolerance range. Check the power supply unit and wiring for faults.
    Event ID: 70000
    Keypad or input device fault. A key may be stuck or the keypad membrane is damaged.
    Inspect the keypad for physical damage or debris causing a key to remain pressed. Clean the keypad surface. If a key is confirmed faulty, the keypad membrane or panel front assembly may need replacement.

    Frequently Asked Questions

    What PLC families are compatible with the OP 77A (6AV6355-1AA47-7DD0)?

    The OP 77A is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP communication interfaces.

    What software is used to configure and program the OP 77A?

    The OP 77A is configured using Siemens WinCC flexible 2005 or later versions. Projects are compiled and downloaded to the panel via the MPI interface or a direct PC adapter connection.

    What is the supply voltage for the 6AV6355-1AA47-7DD0?

    The panel operates on a 24 V DC supply voltage. The supply must be within the specified tolerance range for correct operation.

    What is the front panel protection rating of the OP 77A?

    The front face of the OP 77A carries an IP65 protection rating, making it suitable for panel-mounting in environments with dust and water spray exposure.

    Does the OP 77A support touch input?

    No, the OP 77A is a keypad-based operator panel and does not support touch screen input. User interaction is performed via the membrane keypad with function keys and numeric entry keys.

    Troubleshooting

    Panel display remains blank after power on

    Check that 24 V DC is present at the power supply terminals of the panel using a multimeter. Verify polarity is correct. Inspect internal fuse if accessible.

    Restore correct 24 V DC supply voltage. Replace any blown fuse with the correct rating. If the display remains blank with confirmed correct supply, the internal power supply board or display assembly may require replacement.

    Panel cannot communicate with the SIMATIC PLC

    Verify MPI or PROFIBUS DP address settings on both the panel and PLC match the WinCC flexible project configuration. Check cable connections, bus termination resistors at both ends of the bus, and cable continuity.

    Correct any address mismatches in the WinCC flexible project and re-download. Replace damaged cables and ensure proper bus termination. Confirm the PLC is powered and in RUN or STOP mode as required.

    Project download from PC to panel fails

    Check the PC adapter or MPI cable connection between the engineering PC and the panel. Confirm the correct communication port and transfer settings are selected in WinCC flexible. Verify the project compiles without errors.

    Use a known-good PC adapter cable. Set the correct COM port and baud rate in WinCC flexible transfer settings. Recompile the project and retry the download. If the panel is unresponsive, perform a factory reset before attempting the download again.

    Function keys do not respond or produce incorrect actions

    Inspect the keypad membrane for physical damage, contamination, or a stuck key. Verify the key assignments in the WinCC flexible project are correctly configured for the expected functions.

    Clean the keypad surface to remove any debris. If a key is physically damaged, the keypad membrane assembly should be replaced. If the key assignments are incorrect, update the project configuration and re-download to the panel.

    Panel displays communication timeout alarm repeatedly during operation

    Monitor the MPI or PROFIBUS DP bus for signal integrity issues. Check for loose connectors, damaged cable shielding, or missing bus termination. Verify the PLC scan cycle time is within the configured watchdog timeout period.

    Secure all cable connections and replace damaged cables. Add or correct bus termination resistors. Increase the communication watchdog timeout in the WinCC flexible project if the PLC cycle time is long. Reduce bus cable length if signal quality is poor.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart