• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1AA47-7DA1 OP 77A
    Awaiting product image

    Siemens 6AV6355-1AA47-7DA1 OP 77A

    € 1.338,50

    Reset
    Clear
    SKU: 6AV6355-1AA47-7DA1 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1AA47-7DA1 is an operator panel belonging to the SIMATIC HMI OP 77A series, designed for machine-level human-machine interface applications. This compact panel provides a key-based interface for process visualization and operator control in industrial automation environments. It is part of Siemens' SIMATIC HMI portfolio and is intended for use with SIMATIC S7 and other compatible controllers.

    The OP 77A features a monochrome LCD display with a resolution of 160 x 80 pixels, providing clear readout of process values, alarms, and status messages. The panel supports MPI and PROFIBUS DP communication interfaces, enabling direct integration with Siemens S7-200, S7-300, and S7-400 PLCs. It includes function keys and system keys for operator input, and is configured using the WinCC flexible engineering software. The unit operates on a 24 V DC supply and is rated for industrial environments with an IP65 protection rating on the front panel.

    The OP 77A is commonly deployed in machine building, conveyor systems, packaging machinery, and process automation where a compact, cost-effective operator interface is required. Its rugged construction and compatibility with the SIMATIC controller family make it suitable for integration into existing Siemens automation architectures. The panel is well-suited for applications requiring alarm display, recipe management, and basic process value visualization at the machine level.

    Technical Specifications

    Display Type Monochrome LCD
    Display Resolution 160 x 80 pixels
    Input Voltage 24 V DC
    Power Consumption Max. 4.5 W
    Communication Interface MPI, PROFIBUS DP
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Mounting Panel mounting
    Engineering Software WinCC flexible 2005 or higher
    Certifications CE, UL, cULus
    Series SIMATIC HMI OP 77A

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC. The connection to the controller has been interrupted or cannot be established.
    Check MPI or PROFIBUS DP cable connections and terminating resistors. Verify the PLC address settings and ensure the PLC is in RUN mode. Check the communication parameters configured in WinCC flexible.
    Event ID: 10001
    Connection timeout to the configured PLC. The panel did not receive a response from the controller within the expected time.
    Verify network cabling and connector integrity. Confirm the PLC station address matches the project configuration. Restart both the panel and the PLC if the issue persists.
    Event ID: 20000
    Tag read error. The panel is unable to read a configured process tag from the PLC.
    Check that the tag address in WinCC flexible matches the actual PLC data block or memory address. Verify the PLC program contains the referenced data area.
    Event ID: 20001
    Tag write error. The panel is unable to write a value to the configured PLC tag.
    Confirm the PLC memory area is not write-protected. Verify the tag address configuration in WinCC flexible and ensure the PLC is in a state that accepts write commands.
    Event ID: 40000
    Project download error. A project transfer from the engineering PC to the panel has failed.
    Check the transfer cable connection and ensure the panel is in transfer mode. Verify that the WinCC flexible project is compatible with the OP 77A firmware version. Retry the download.
    Event ID: 50000
    System memory low. The panel's available memory for runtime operation is critically low.
    Reduce the number of configured screens, tags, or alarm messages in the WinCC flexible project. Reload the project after optimization.
    Event ID: 60000
    Firmware update error. An error occurred during a firmware update procedure on the panel.
    Ensure the correct firmware version for the OP 77A is used. Repeat the update procedure using the ProSave tool and verify the connection between the PC and the panel.
    Event ID: 70000
    Alarm buffer overflow. The number of pending alarms has exceeded the panel's alarm buffer capacity.
    Acknowledge and clear existing alarms on the panel. Review the alarm configuration in WinCC flexible to reduce unnecessary alarm triggers or increase acknowledgement frequency.

    Frequently Asked Questions

    Which communication interfaces does the OP 77A support?

    The OP 77A supports MPI and PROFIBUS DP interfaces, allowing direct connection to Siemens S7-200, S7-300, and S7-400 PLCs without an additional communication module.

    Which engineering software is required to configure the OP 77A?

    The OP 77A is configured using Siemens WinCC flexible 2005 or a later version. Projects are downloaded to the panel via the MPI interface or a dedicated transfer cable.

    What is the supply voltage for the 6AV6355-1AA47-7DA1?

    The panel operates on a 24 V DC supply voltage, which is standard for SIMATIC HMI devices in industrial cabinet installations.

    What is the front panel protection rating of the OP 77A?

    The front panel of the OP 77A is rated IP65, making it resistant to dust ingress and low-pressure water jets, suitable for most industrial machine environments.

    Can the OP 77A be used with third-party PLCs?

    The OP 77A is primarily designed for use with Siemens SIMATIC S7 controllers via MPI or PROFIBUS DP. Connectivity to third-party PLCs is limited and depends on PROFIBUS DP compatibility of the third-party device.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the panel's power connector. Verify that the supply is within the specified range and that the connector is firmly seated.

    Restore correct 24 V DC supply. If the supply is confirmed correct and the display remains blank, the internal power supply or backlight may be faulty and the unit should be sent for repair or replacement.

    Panel shows 'No connection to PLC' message on startup

    Verify the MPI or PROFIBUS DP cable is correctly connected to both the panel and the PLC. Check that the bus termination resistors are correctly placed at both ends of the network.

    Correct any wiring faults and ensure proper bus termination. Confirm that the PLC station address in the WinCC flexible project matches the actual PLC configuration. Restart the panel after corrections.

    Project download from PC to panel fails

    Ensure the panel is set to transfer mode by pressing the appropriate key combination on startup. Verify the transfer cable type and PC COM port settings are correct.

    Place the panel in transfer mode, select the correct interface in WinCC flexible transfer settings, and retry the download. If using USB-to-serial adapters, try a different adapter or a direct serial connection.

    Operator keys are unresponsive or behave incorrectly

    Check whether the issue is consistent across all keys or limited to specific ones. Inspect the keypad membrane for physical damage or contamination.

    Clean the keypad area if contamination is present. If specific keys are permanently unresponsive, the keypad membrane may require replacement. Contact a qualified repair service for internal keypad replacement.

    Alarms are not displayed or acknowledged correctly

    Review the alarm configuration in the WinCC flexible project to confirm that alarm tags are correctly mapped to PLC addresses. Check that the PLC is setting the alarm bits as expected.

    Correct any tag address mismatches in the WinCC flexible project and reload the project to the panel. Verify PLC logic is correctly triggering alarm bits and that acknowledgement handling is configured properly.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart