
Siemens 6AV6355-1AA47-7CD4 OP 77A
€ 3.495,00
The Siemens 6AV6355-1AA47-7CD4 is an operator panel belonging to the OP 77A series within the Siemens SIMATIC HMI product family. This compact panel operator unit is designed for machine-level human-machine interface applications, providing a keypad-based interface for process visualization and control. It is part of the SIMATIC HMI Basic Panels generation and is intended for use with Siemens SIMATIC S7 and other compatible controllers.
The OP 77A features a monochrome LCD display with a resolution suitable for text and simple graphic display, along with a membrane keypad for operator input. It supports MPI and PROFIBUS DP communication interfaces, enabling direct integration into Siemens automation networks. The panel is configured using Siemens WinCC flexible software and supports alarm management, recipe handling, and trend display functions within its memory constraints.
The OP 77A is commonly deployed in manufacturing machinery, packaging equipment, and process automation systems where a cost-effective, robust operator interface is required. Its compact form factor and keypad-based operation make it well suited for environments where touchscreen panels are not practical, such as applications with gloved operators or high-vibration conditions. It is widely used in the automotive, food and beverage, and general manufacturing industries.
Technical Specifications
| Display Type | Monochrome LCD |
|---|---|
| Display Size | 4 inches |
| Display Colors | Monochrome (blue/white) |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 4.5 W |
| Communication Interface | MPI, PROFIBUS DP |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP/Protection Rating | IP65 (front panel) |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC HMI OP 77A |
| Configuration Software | WinCC flexible 2005 or higher |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between the HMI panel and the connected PLC controller.
Check MPI/PROFIBUS DP cable connections and termination resistors. Verify the configured station address matches the physical network settings. Restart the panel and PLC. - Event ID: 10001
- Connection to the PLC has been interrupted or timed out.
Inspect the communication cable for damage. Verify baud rate and network address settings in WinCC flexible project. Ensure the PLC is powered and in RUN mode. - Event ID: 20000
- Project download error or project data corrupted on the panel.
Re-download the WinCC flexible project to the panel. Check USB or MPI transfer cable integrity. Ensure the project was compiled without errors before transfer. - Event ID: 40000
- Internal device error or hardware fault detected.
Perform a factory reset of the panel. If the fault persists, the internal hardware may require service or the unit may need replacement. - Event ID: 50000
- Alarm buffer overflow — too many alarms generated in a short period.
Acknowledge and clear pending alarms. Review the alarm configuration in the WinCC flexible project to reduce unnecessary alarm triggers. - Event ID: 60000
- Recipe data error — recipe record could not be read or written.
Check recipe configuration in the WinCC flexible project. Verify that the PLC data blocks referenced by the recipe are correctly defined and accessible. - Event ID: 70000
- Operator input rejected — key input not accepted by the current screen object.
Verify that the screen object is correctly configured for operator input. Check that the associated PLC variable is writable and within the defined limits.
Frequently Asked Questions
What communication interfaces does the OP 77A (6AV6355-1AA47-7CD4) support?
The OP 77A supports MPI and PROFIBUS DP communication interfaces, allowing direct connection to Siemens S7-200, S7-300, and S7-400 PLCs as well as other PROFIBUS-compatible controllers.
What software is required to configure and program this panel?
The panel is configured using Siemens WinCC flexible 2005 or a later compatible version. The project is transferred to the panel via MPI cable or USB-to-MPI adapter.
What is the supply voltage for the 6AV6355-1AA47-7CD4?
The panel operates on a 24 V DC supply voltage, which is standard for SIMATIC HMI panels in this series.
What is the front panel protection rating of the OP 77A?
The front panel of the OP 77A carries an IP65 protection rating, making it suitable for use in environments where dust and water spray may be present.
Can this panel be used as a replacement for older Siemens OP7 or OP17 panels?
The OP 77A is designed as a functional successor to older Siemens operator panels such as the OP7 and OP17, and can serve as a replacement with appropriate project adaptation in WinCC flexible.
Troubleshooting
Display remains blank after power on
Measure the 24 V DC supply voltage at the panel's power connector. Check for correct polarity. Inspect the internal fuse if accessible.
Ensure the 24 V DC supply is stable and within tolerance. Replace the supply fuse if blown. If the display remains blank with correct supply voltage, the internal power supply or display backlight may have failed and the unit requires repair or replacement.
Panel displays 'No connection to PLC' or communication error on startup
Verify the MPI or PROFIBUS DP cable is securely connected at both the panel and PLC ends. Check that bus termination resistors are correctly placed at both ends of the network segment.
Correct any loose connections or damaged cables. Ensure the panel's configured station address and baud rate match the PLC network settings. Re-download the project if configuration changes are made.
Panel keypad buttons are unresponsive or intermittently responsive
Inspect the membrane keypad for physical damage, contamination, or wear. Test each key systematically in the panel's service or test mode if available.
Clean the keypad surface with a dry cloth. If individual keys have failed due to wear, the membrane keypad assembly may need to be replaced. Contact a qualified repair technician for keypad replacement.
Project download fails or panel does not accept new project
Check the MPI transfer cable connection and driver installation on the programming PC. Verify that WinCC flexible project has been compiled without errors and is compatible with the panel firmware version.
Reinstall the MPI adapter drivers on the PC. Perform a panel reset to factory defaults before re-attempting the download. Ensure the WinCC flexible version matches the panel's supported firmware generation.
Alarms are not displayed or alarm history is missing
Check the alarm configuration in the WinCC flexible project to confirm alarms are correctly linked to PLC bit variables. Verify that the PLC variables are being updated and that the communication link is active.
Correct any misconfigured alarm triggers in the WinCC flexible project and re-download to the panel. Ensure the PLC program is setting the correct alarm bits and that the panel has sufficient memory allocated for the alarm buffer.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page



