• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1AA47-7CB4 OP 77A
    Awaiting product image

    Siemens 6AV6355-1AA47-7CB4 OP 77A

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6355-1AA47-7CB4 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1AA47-7CB4 is an operator panel belonging to the OP 77A series, part of the SIMATIC HMI Basic Panels product family manufactured by Siemens. This compact operator panel is designed for straightforward machine-level visualization and control tasks, offering a monochrome display for process monitoring and operator interaction. It integrates into Siemens automation environments and is configured using the WinCC flexible engineering software.

    The OP 77A features a monochrome STN LCD display with a resolution of 160 x 80 pixels, providing clear readability of process values, alarms, and status messages. It supports MPI and PROFIBUS DP communication interfaces, enabling direct connection to Siemens S7-200, S7-300, and S7-400 PLCs. The panel includes function keys for operator input, an integrated real-time clock, and non-volatile memory for project data retention without battery backup. The unit operates on a 24 V DC supply and is rated IP65 on the front face for protection against dust and water ingress.

    The OP 77A is typically deployed in manufacturing, packaging, and process automation applications where a cost-effective, reliable operator interface is required at the machine level. Its compact form factor and robust front panel protection make it suitable for installation in control cabinet doors and machine enclosures across industries such as food and beverage, automotive, and general factory automation. The panel is well suited for applications requiring basic alarm management, recipe handling, and process value display without the need for a full graphical color interface.

    Technical Specifications

    Display Type Monochrome STN LCD
    Display Resolution 160 x 80 pixels
    Display Colors Monochrome (blue/white)
    Input/Operating Voltage 24 V DC
    Communication Interface MPI, PROFIBUS DP
    IP/Protection Rating IP65 (front), IP20 (rear)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Mounting Panel mounting
    Series/Product Family SIMATIC HMI OP 77A
    Configuration Software WinCC flexible 2005 or higher
    PLC Compatibility S7-200, S7-300, S7-400
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC. The connection to the controller has been interrupted or cannot be established.
    Check MPI/PROFIBUS DP cable connections and terminating resistors. Verify the PLC address settings match the HMI project configuration. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Connection to PLC timed out. The panel did not receive a response from the controller within the expected time window.
    Check network cable integrity and connector seating. Verify baud rate and station address settings on both the HMI and PLC. Reduce network cable length or check for bus termination issues.
    Event ID: 20000
    Project download error. A fault occurred during the transfer of the project from the engineering PC to the HMI panel.
    Verify the transfer cable and PC interface settings. Ensure WinCC flexible is set to the correct transfer mode and the panel is in transfer mode. Retry the download after restarting both devices.
    Event ID: 40000
    System memory low. The available memory for runtime operation is insufficient to load or run the current project.
    Reduce the project size by removing unused screens, tags, or alarm entries. Recompile and re-download the project using WinCC flexible.
    Event ID: 50000
    Operating system error. An internal system fault has been detected in the HMI panel firmware.
    Perform a panel reset by cycling power. If the fault persists, update or reinstall the panel firmware using the appropriate Siemens ProSave tool.
    Event ID: 60000
    Tag read/write error. A configured tag could not be read from or written to the connected PLC.
    Verify the tag address in the WinCC flexible project matches the actual PLC data block or memory address. Check PLC program for address conflicts or protected data areas.

    Frequently Asked Questions

    Which PLCs are compatible with the Siemens OP 77A (6AV6355-1AA47-7CB4)?

    The OP 77A is compatible with Siemens S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with other controllers supported by WinCC flexible drivers.

    What software is required to configure the OP 77A?

    The OP 77A is configured using Siemens WinCC flexible 2005 or a later version. Projects are downloaded to the panel via a PC adapter cable connected to the MPI interface.

    What is the supply voltage for the OP 77A?

    The OP 77A operates on a 24 V DC supply voltage. Ensure the power supply is within the specified tolerance range to avoid panel faults.

    What is the front panel protection rating of the OP 77A?

    The front face of the OP 77A is rated IP65, providing protection against dust ingress and low-pressure water jets. The rear of the unit is rated IP20.

    Does the OP 77A support recipe management?

    Yes, the OP 77A supports basic recipe management functionality, allowing operators to store and transfer parameter sets between the HMI and the connected PLC.

    Troubleshooting

    Display remains blank after power on

    Check that 24 V DC is present at the power supply terminals. Measure voltage directly at the panel connector to rule out wiring faults. Inspect for any visible damage to the unit.

    Verify and restore the 24 V DC supply. If voltage is correct and the display remains blank, the internal power supply or backlight may have failed and the unit should be sent for repair or replacement.

    HMI panel shows communication error to PLC

    Inspect the MPI or PROFIBUS DP cable for damage or loose connectors. Verify bus termination is correctly applied at both ends of the network. Check that the PLC station address in the HMI project matches the actual PLC configuration.

    Replace or reseat the communication cable. Correct any address mismatches in the WinCC flexible project and re-download. Ensure bus termination resistors are enabled only at the physical ends of the network.

    Panel does not enter transfer mode for project download

    Confirm the panel is set to transfer mode either via the Start Center menu or by holding the appropriate key combination during boot. Check that the PC adapter is correctly connected and the COM port or USB driver is functioning.

    Restart the panel and access the Start Center to manually select Transfer mode. Reinstall the PC adapter driver on the engineering PC if the connection is not recognized. Verify the correct interface is selected in WinCC flexible transfer settings.

    Operator function keys are unresponsive

    Check whether the issue affects all keys or specific keys only. Test key response in the panel's Start Center menu to determine if the fault is hardware or project-related.

    If keys are unresponsive in the Start Center, the keypad membrane may be damaged and requires hardware repair. If keys work in the Start Center but not in the project, review the key assignments in the WinCC flexible project and re-download.

    Alarm messages are not displayed on the panel

    Verify that the alarm tags are correctly configured in the WinCC flexible project and that the corresponding PLC bit addresses are correct. Check the PLC program to confirm alarm bits are being set as expected.

    Correct any tag address mismatches in the alarm configuration and re-download the project. Confirm the PLC program logic is activating the alarm bits. Ensure the alarm view object is present and correctly configured on the relevant HMI screen.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart