• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1AA47-7BE1 OP 77A
    Awaiting product image

    Siemens 6AV6355-1AA47-7BE1 OP 77A

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6355-1AA47-7BE1 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1AA47-7BE1 is an operator panel belonging to the OP 77A series within the Siemens SIMATIC HMI product family. This compact panel operator unit is designed for machine-level human-machine interface applications, providing operators with a straightforward interface for monitoring and controlling industrial processes. The OP 77A series is part of the broader SIMATIC HMI Basic Panels generation and is engineered for integration into standard control cabinet doors and machine panels.

    The 6AV6355-1AA47-7BE1 features a monochrome LCD display and a membrane keypad with function keys, numeric keys, and system keys for direct operator input without requiring a touchscreen. It supports MPI and PROFIBUS DP communication interfaces for direct connection to Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel is configured using Siemens WinCC flexible software, allowing the creation of screens, alarms, recipes, and trend displays suited to the device's capabilities.

    The OP 77A is widely deployed in manufacturing, packaging, material handling, and process automation environments where a cost-effective, robust operator interface is required at the machine level. Its compact form factor and keypad-based operation make it suitable for installations where space is limited or where touchscreen operation is not practical due to environmental conditions such as the presence of gloves or contaminants. The panel is commonly found on standalone machines and production lines across the automotive, food and beverage, and general manufacturing industries.

    Technical Specifications

    Display Type Monochrome LCD
    Display Size 4 inches
    Communication Interface MPI, PROFIBUS DP
    Configuration Software WinCC flexible 2008
    Input Voltage 24 V DC
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL
    Series SIMATIC HMI OP 77A

    Common Error Codes & System Events

    Event ID: 10000
    Configuration error detected on startup; the loaded project is incompatible with the panel firmware version.
    Reload the project using a compatible version of WinCC flexible and ensure firmware is updated to match the project requirements.
    Event ID: 10001
    Communication connection to the PLC has been lost or cannot be established.
    Check MPI or PROFIBUS DP cable connections, verify bus address settings on both the panel and PLC, and confirm the PLC is powered and in RUN mode.
    Event ID: 20000
    No project found on the device; the panel has started in transfer mode.
    Transfer a valid project to the panel using WinCC flexible via MPI, PROFIBUS, or USB/serial connection.
    Event ID: 20001
    Project transfer failed due to a communication error during download.
    Verify the transfer cable and interface settings, ensure the correct COM port or MPI address is selected in WinCC flexible, and retry the transfer.
    Event ID: 40000
    Alarm buffer overflow; the number of pending alarms has exceeded the panel's buffer capacity.
    Acknowledge and clear existing alarms on the panel. Review the alarm configuration in WinCC flexible to reduce unnecessary alarm triggers.
    Event ID: 50000
    Recipe data error; a recipe record could not be read or written correctly.
    Check the recipe configuration in WinCC flexible for correct tag assignments and data types. Verify PLC tag values are within the defined limits.
    Event ID: 60000
    Internal device error or watchdog timeout detected.
    Perform a power cycle of the panel. If the error persists, perform a factory reset and reload the project. Contact Siemens technical support if the fault recurs.

    Frequently Asked Questions

    Which PLCs are compatible with the Siemens OP 77A (6AV6355-1AA47-7BE1)?

    The OP 77A is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP communication interfaces. It can also communicate with S7-200 via the PPI protocol.

    What software is used to configure the OP 77A panel?

    The OP 77A is configured using Siemens WinCC flexible 2008 or later. Projects are downloaded to the panel via MPI, PROFIBUS DP, or a serial/USB PC adapter.

    What is the supply voltage for the 6AV6355-1AA47-7BE1?

    The panel requires a 24 V DC supply voltage, which is the standard supply for SIMATIC HMI operator panels.

    Does the OP 77A support touchscreen operation?

    No, the OP 77A uses a membrane keypad with function keys, numeric keys, and system keys. It does not have a touchscreen display.

    What is the front panel protection rating of the OP 77A?

    The front panel of the OP 77A carries an IP65 protection rating, making it suitable for installation in environments where dust and water jets may be present.

    Troubleshooting

    Panel display remains blank after power is applied

    Measure the 24 V DC supply voltage at the power connector on the rear of the panel. Check for correct polarity. Inspect the internal fuse if accessible.

    Ensure the 24 V DC supply is within the specified tolerance. Replace any blown fuse with the correct rating. If the supply is correct and the display remains blank, the internal power supply or display backlight may require replacement.

    Panel shows 'Connecting…' and cannot establish communication with the PLC

    Verify the MPI or PROFIBUS DP cable is securely connected at both ends. Check that the bus address configured on the panel matches the project settings and does not conflict with other devices on the bus.

    Correct any address conflicts, replace damaged cables, and ensure bus termination resistors are correctly placed at both ends of the PROFIBUS or MPI network. Confirm the PLC is powered and in RUN or STOP mode.

    Project transfer from WinCC flexible fails repeatedly

    Check the PC adapter type and interface settings in WinCC flexible. Confirm the correct COM port or USB adapter driver is installed and that the panel is in transfer mode.

    Set the panel to transfer mode manually via the Start Center menu. Verify the PC adapter is functioning correctly by testing with another device. Reinstall the PC adapter driver if necessary and retry the transfer.

    Function keys do not respond or produce incorrect actions

    Check the project configuration in WinCC flexible to verify that function key assignments are correctly mapped to the intended actions or screens.

    Re-download the project after correcting key assignments. If keys are physically unresponsive, inspect the membrane keypad for damage or contamination and replace the keypad assembly if required.

    Panel restarts unexpectedly or enters an error loop on startup

    Determine whether the panel is displaying a specific event ID or error message during the restart cycle. Check if the loaded project is compatible with the current panel firmware version.

    Update the panel firmware using the Siemens ProSave tool and reload the project using a compatible version of WinCC flexible. If the issue persists after a firmware update and project reload, perform a factory reset via the Start Center.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart