• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1AA47-7BA0 OP 77A
    Awaiting product image

    Siemens 6AV6355-1AA47-7BA0 OP 77A

    Reset

    This product is currently out of stock and unavailable.

    SKU: 6AV6355-1AA47-7BA0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1AA47-7BA0 is an operator panel belonging to the OP 77A series within the Siemens SIMATIC HMI product family. It is a compact, key-operated panel designed for machine-level human-machine interface applications, providing operators with a straightforward means of monitoring and controlling industrial processes. This unit is part of the SIMATIC HMI Basic Panels generation and is manufactured by Siemens AG.

    The OP 77A features a monochrome STN LCD display and a membrane keypad with function keys, system keys, and numeric entry keys for operator input. It supports MPI and PROFIBUS DP communication interfaces, enabling direct connection to Siemens S7-200, S7-300, and S7-400 PLCs. Configuration is performed using Siemens WinCC flexible software, and the panel includes internal flash memory for storing project data and recipes.

    The OP 77A is widely used in manufacturing, packaging, and process automation environments where a cost-effective, robust operator interface is required at the machine level. Its compact form factor and keypad-based operation make it suitable for installation in control cabinets and machine panels where space is limited. Industries such as food and beverage, automotive, and general machine building commonly deploy this panel for local operator control and status monitoring.

    Technical Specifications

    Display Type Monochrome STN LCD
    Display Size 4 inches
    Display Colors Monochrome (blue/white)
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 4.5 W
    Communication Interface MPI, PROFIBUS DP
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP/Protection Rating IP65 (front panel)
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC HMI OP 77A
    Configuration Software WinCC flexible 2005 or higher

    Common Error Codes and System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC. The panel cannot establish or maintain a connection to the controller.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the project configuration. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Connection to PLC interrupted during runtime. The panel lost communication with the configured controller.
    Inspect the communication cable for damage or loose connectors. Check bus termination and cable shielding. Restart the panel and PLC if the connection is not re-established automatically.
    Event ID: 20000
    Project download error. The transfer of the project from the configuration PC to the panel failed.
    Verify the transfer cable and PC interface settings. Ensure the panel is in transfer mode before initiating download. Check WinCC flexible project compatibility with the panel firmware version.
    Event ID: 40000
    Internal device error or hardware fault detected on the panel.
    Perform a panel restart. If the error persists, check the supply voltage at the power connector. Contact Siemens technical support or arrange for unit repair if the fault is not resolved by restart.
    Event ID: 50000
    Firmware update error. The firmware update process was interrupted or failed to complete.
    Retry the firmware update using the correct firmware version for the OP 77A. Ensure stable power supply during the update process. Do not power off the panel during firmware transfer.
    Event ID: 60000
    Recipe data error. A recipe record could not be read from or written to internal flash memory.
    Check available internal memory and delete unused recipes if memory is full. Re-download the project to restore recipe configuration. If flash memory errors persist, the panel may require hardware service.
    Event ID: 70000
    Alarm buffer overflow. The number of pending alarms has exceeded the buffer capacity of the panel.
    Acknowledge and clear existing alarms on the panel. Review the alarm configuration in WinCC flexible to reduce the number of simultaneous active alarms. Increase the alarm buffer size in the project settings if possible.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77A panel?

    The OP 77A supports direct connection to Siemens S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with other controllers supported by WinCC flexible drivers.

    What software is required to configure the 6AV6355-1AA47-7BA0?

    The panel is configured using Siemens WinCC flexible 2005 or a later compatible version. The project is then transferred to the panel via a PC adapter cable connected to the MPI or PROFIBUS DP port.

    What is the supply voltage for this operator panel?

    The OP 77A requires a 24 V DC power supply. The supply must be within the specified tolerance range to ensure reliable operation.

    What is the front panel protection rating of the OP 77A?

    The front panel of the OP 77A is rated IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for installation in industrial environments.

    Can the OP 77A display graphics or only text?

    The OP 77A is a keypad-based panel with a monochrome LCD display capable of showing text, simple graphics, and bar graphs as configured in the WinCC flexible project.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the panel power connector. Check that the supply is within the specified tolerance. Inspect the power connector for loose or damaged wiring.

    Restore the correct 24 V DC supply voltage. If the supply is correct and the display remains blank, the internal power supply or display backlight may have failed, requiring panel repair or replacement.

    Panel cannot communicate with the PLC

    Verify the MPI or PROFIBUS DP cable is correctly connected and terminated at both ends. Check that the bus address configured in the panel project matches the physical PLC address. Use a bus diagnostic tool to check for bus errors.

    Replace or reseat the communication cable. Correct the bus address settings in the WinCC flexible project and re-download. Ensure bus termination resistors are enabled only at the physical ends of the bus segment.

    Project download fails or transfer mode cannot be activated

    Confirm the panel is set to transfer mode via the panel start screen or loader menu. Check the PC adapter cable type and the COM port or USB settings on the configuration PC. Verify that WinCC flexible is using the correct transfer settings.

    Restart the panel and re-enter transfer mode. Use the correct Siemens PC adapter (MPI or PROFIBUS) and ensure the driver is properly installed on the PC. Re-attempt the project download from WinCC flexible.

    Function keys do not respond to operator input

    Check whether the panel is in runtime mode and the project has function key assignments configured. Test multiple keys to determine if the issue is isolated to specific keys or affects all keys.

    Re-download the project to ensure the latest key assignments are loaded. If specific keys are unresponsive, the membrane keypad may be worn or damaged and may require replacement of the front panel assembly.

    Panel displays persistent communication alarm during runtime

    Check the PLC status and confirm it is in RUN mode. Inspect the MPI or PROFIBUS DP cable for physical damage, and verify termination and shielding. Review the connection settings in the WinCC flexible project for correct PLC address and interface parameters.

    Correct any wiring or termination faults on the bus. Update the project connection parameters if the PLC address or interface has changed. Restart both the panel and PLC to re-establish communication.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart