• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1AA31-8DL6 OP 77A
    Awaiting product image

    Siemens 6AV6355-1AA31-8DL6 OP 77A

    Reset

    This product is currently out of stock and unavailable.

    SKU: 6AV6355-1AA31-8DL6 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1AA31-8DL6 is an operator panel belonging to the SIMATIC HMI OP 77A series, manufactured by Siemens. It is a compact, key-operated panel designed for machine-level human-machine interface applications, providing operators with a straightforward means of monitoring and controlling automated processes. This unit is part of the SIMATIC HMI product line, which is widely deployed across industrial automation environments worldwide.

    The OP 77A features a monochrome LCD display and a membrane keypad with function keys, system keys, and numeric entry keys for direct operator input. It supports the MPI (Multi-Point Interface) and PROFIBUS DP communication protocols, enabling seamless integration with SIMATIC S7-200, S7-300, and S7-400 PLCs. Configuration is performed using Siemens WinCC flexible software, and the panel includes internal flash memory for storing project data and recipes. The unit operates on a 24 V DC supply and is designed to meet IP65 protection on the front panel for use in industrial enclosures.

    The OP 77A is typically used in machine building, manufacturing automation, and process control applications where a cost-effective, robust operator interface is required. It is well suited for packaging machinery, conveyor systems, and general-purpose machine control panels. Its compact form factor and keypad-based operation make it appropriate for environments where touchscreen interfaces are not practical or necessary.

    Technical Specifications

    Display Type Monochrome LCD
    Display Size 4 lines x 20 characters
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 5 W
    Communication Interface MPI, PROFIBUS DP
    IP Protection Rating (Front) IP65
    IP Protection Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10 % to 90 %, non-condensing
    Configuration Software WinCC flexible 2005 or higher
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400
    Mounting Panel mounting
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the OP 77A and the connected PLC. The panel cannot establish or maintain a connection to the controller.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the project configuration. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    PLC address not reachable. The configured PLC station address cannot be found on the network.
    Verify the station address configured in WinCC flexible matches the actual PLC address. Check bus cable integrity and termination.
    Event ID: 20000
    Project download error. A fault occurred during transfer of the project from the configuration PC to the panel.
    Check the PC-to-panel transfer cable and connection. Ensure the panel is in transfer mode before initiating download. Retry the download from WinCC flexible.
    Event ID: 40000
    Internal memory error. The panel has detected a fault in its internal flash memory or project data is corrupted.
    Re-download the project to the panel using WinCC flexible. If the error persists, perform a factory reset and re-download.
    Event ID: 50000
    Configuration error. The loaded project contains settings incompatible with this panel type or firmware version.
    Verify the project was configured for the OP 77A panel type in WinCC flexible. Update panel firmware if necessary and re-download the project.
    Event ID: 60000
    Firmware update error. An error occurred during a firmware update procedure.
    Restart the firmware update process. Ensure stable power supply during update and use the correct firmware version for the OP 77A.
    Event ID: 70000
    Watchdog timeout. The panel's internal watchdog has triggered due to a system hang or software fault.
    Cycle power to the panel. If the fault recurs frequently, re-download the project and check for excessive tag polling loads in the configuration.

    Frequently Asked Questions

    What communication protocols does the OP 77A (6AV6355-1AA31-8DL6) support?

    The OP 77A supports MPI and PROFIBUS DP communication protocols, allowing direct connection to SIMATIC S7-200, S7-300, and S7-400 PLCs.

    What software is required to configure the OP 77A?

    The OP 77A is configured using Siemens WinCC flexible 2005 or a later compatible version. Projects are downloaded to the panel via a PC adapter cable.

    What is the supply voltage for the 6AV6355-1AA31-8DL6?

    The panel operates on a 24 V DC supply voltage, which is standard for SIMATIC HMI operator panels.

    What is the front panel protection rating of the OP 77A?

    The OP 77A provides IP65 protection on the front face when correctly installed in a panel cutout, making it suitable for environments with dust and water spray.

    Can the OP 77A be used with an S7-1200 or S7-1500 PLC?

    The OP 77A is not natively supported for direct communication with S7-1200 or S7-1500 PLCs, as these controllers use newer communication protocols. It is designed for use with S7-200, S7-300, and S7-400 series controllers.

    Troubleshooting

    Display remains blank after power is applied

    Check that 24 V DC is present at the power supply terminals of the panel. Measure voltage at the connector to confirm supply integrity. Inspect for any blown internal fuse.

    Ensure the 24 V DC supply is within tolerance. Replace any blown fuse with the correct rating. If supply is confirmed good and display remains blank, the internal power supply board or LCD may require replacement.

    Panel displays communication error and cannot connect to PLC

    Verify the MPI or PROFIBUS DP cable is correctly connected and terminated at both ends. Check that the PLC address in the panel project matches the physical PLC address setting.

    Replace or reseat the communication cable. Correct the station address in WinCC flexible and re-download the project. Ensure termination resistors are enabled only at the two physical ends of the bus.

    Project download fails or transfer cannot be initiated

    Confirm the panel is set to transfer mode before starting the download from WinCC flexible. Check the PC adapter cable connection between the PC and the panel's MPI port.

    Place the panel in transfer mode via the start screen menu. Use a compatible Siemens PC adapter (USB or RS-232). Retry the download. If failure persists, perform a panel reset and attempt again.

    Function keys do not respond to presses

    Inspect the membrane keypad for physical damage, contamination, or deformation. Test each key in a diagnostic screen if available in the project.

    Clean the keypad surface. If individual keys are non-functional due to membrane damage, the keypad membrane assembly should be replaced. Contact a repair specialist for membrane replacement.

    Panel repeatedly restarts or watchdog resets occur

    Check the 24 V DC supply for voltage dips or instability under load. Review the project configuration for excessive tag update rates or communication polling loads.

    Stabilize the power supply, ensuring it can deliver sufficient current. Reduce tag polling frequency in WinCC flexible. Re-download the project. If restarts continue, the panel may require servicing of its internal CPU board.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart