• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6344-2AD24-0MG7 OP177B
    Awaiting product image

    Siemens 6AV6344-2AD24-0MG7 OP177B

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6344-2AD24-0MG7 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6344-2AD24-0MG7 is an OP177B operator panel belonging to the SIMATIC HMI series, designed for machine-level visualization and operator control in industrial automation environments. This unit provides a monochrome display interface for process monitoring and control, and is part of Siemens' established line of operator panels intended for panel mounting in control cabinets and machinery. The OP177B is configured for use with SIMATIC S7 and other compatible Siemens controllers via standard communication interfaces.

    The 6AV6344-2AD24-0MG7 features a 5.7-inch STN monochrome display with a resolution of 320 x 240 pixels, offering clear readability in industrial lighting conditions. The panel supports MPI and PROFIBUS DP communication interfaces, enabling direct integration with SIMATIC S7-200, S7-300, and S7-400 PLCs. It includes function keys and a membrane keypad for operator input, with configurable softkeys for application-specific control. The unit operates on a 24 V DC supply and is rated IP65 at the front panel, providing protection against dust and water ingress in demanding environments.

    The OP177B is widely deployed in machine tool control, conveyor systems, packaging machinery, and process plant equipment where a compact, robust operator interface is required. Its compatibility with the SIMATIC S7 controller family makes it a practical choice for retrofitting existing S7-based installations or building new control panels. The panel is configured using WinCC flexible engineering software, which supports structured project development and reuse across the SIMATIC HMI product range.

    Technical Specifications

    Display Size 5.7 inch
    Display Type STN monochrome
    Display Resolution 320 x 240 pixels
    Input Voltage 24 V DC
    Voltage Range 19.2 – 28.8 V DC
    Communication Interface MPI, PROFIBUS DP
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10 % to 90 %, non-condensing
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Engineering Software WinCC flexible
    Series SIMATIC HMI OP177B

    Common Error Codes & System Events

    Event ID: 10000
    Configuration error detected on startup; the loaded project is incompatible with the panel firmware version.
    Re-transfer the project using a compatible version of WinCC flexible. Ensure firmware and project versions match.
    Event ID: 20000
    Communication link to the PLC has been interrupted or cannot be established.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify PLC address settings and baud rate configuration in the project.
    Event ID: 40000
    Tag read/write error; the panel cannot access a configured PLC data address.
    Verify the PLC data block and address referenced in the HMI project exist and are accessible. Check PLC program for address conflicts.
    Event ID: 50000
    Project download failed or was interrupted during transfer to the panel.
    Restart the transfer process from WinCC flexible. Check the transfer cable or network connection and ensure the panel is in transfer mode.
    Event ID: 60000
    Internal panel memory error or corrupted project data detected.
    Perform a factory reset on the panel and re-transfer the project. If the error persists, the internal flash memory may require service.
    Event ID: 70000
    Licence or runtime error; the HMI runtime could not start correctly.
    Check that the correct runtime licence is present on the panel. Re-transfer the project and restart the device.
    Event ID: 80000
    Power supply undervoltage detected; supply voltage has dropped below the minimum operating threshold.
    Measure the 24 V DC supply at the panel connector. Ensure the power supply unit is rated for the panel load and check wiring for voltage drop.

    Frequently Asked Questions

    Which PLCs are compatible with the OP177B 6AV6344-2AD24-0MG7?

    The OP177B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with other Siemens controllers that support these protocols.

    What software is used to configure and program the OP177B?

    The OP177B is configured using Siemens WinCC flexible engineering software. Projects are transferred to the panel via MPI, PROFIBUS DP, or a serial PC/PPI cable.

    What is the front panel protection rating of the 6AV6344-2AD24-0MG7?

    The front panel of the OP177B is rated IP65, providing full protection against dust ingress and protection against low-pressure water jets.

    What is the supply voltage requirement for this panel?

    The OP177B requires a 24 V DC supply with an operating range of 19.2 V DC to 28.8 V DC.

    Can the OP177B be used as a replacement for older SIMATIC OP panels?

    Yes, the OP177B is designed to be compatible with and serve as a replacement for older SIMATIC OP7 and OP17 operator panels, with appropriate project migration in WinCC flexible.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the panel power connector using a multimeter. Verify the voltage is within the 19.2–28.8 V DC operating range. Inspect the supply wiring and connector for loose connections.

    Restore the supply voltage to within specification. If voltage is correct and the display remains blank, the internal power supply board or backlight may be faulty and the unit should be sent for repair or replacement.

    Panel displays 'No connection to PLC' or communication alarm on screen

    Inspect the MPI or PROFIBUS DP cable for physical damage and verify correct termination at both ends of the bus. Check that the PLC address and baud rate configured in the HMI project match the actual PLC settings.

    Replace or reseat the communication cable. Correct any address or baud rate mismatches in the WinCC flexible project and re-transfer to the panel. Ensure bus termination resistors are correctly placed at the bus endpoints.

    Project transfer from WinCC flexible fails or times out

    Verify the transfer cable connection between the PC and the panel. Confirm the panel is set to transfer mode (accessible via the Start Center or loader menu). Check that the WinCC flexible version is compatible with the panel firmware.

    Restart the panel in transfer mode and retry the download. Update or match the WinCC flexible version to the panel firmware. If using a USB-to-serial adapter, ensure the correct driver is installed and the COM port is correctly assigned.

    Touchscreen or keypad inputs are not responding correctly

    For keypad issues, inspect the membrane keypad connector internally for corrosion or damage. Check whether the fault is consistent across all keys or limited to specific keys, which may indicate a partial membrane failure.

    Clean the keypad connector contacts. If individual keys are unresponsive, the membrane keypad assembly requires replacement. For persistent issues across all inputs, the main CPU board may require inspection.

    Panel repeatedly restarts or enters a boot loop

    This may indicate corrupted firmware or a failed project transfer. Attempt to access the Start Center or loader menu during boot by pressing the appropriate key combination. Check the 24 V DC supply for voltage fluctuations.

    Perform a firmware update or factory reset via the Start Center. Re-transfer a valid project using WinCC flexible. If the boot loop persists after firmware restoration, the internal flash memory or CPU module may be defective.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart