• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6344-2AD14-0MF6 OP 177B
    Awaiting product image

    Siemens 6AV6344-2AD14-0MF6 OP 177B

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6344-2AD14-0MF6 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6344-2AD14-0MF6 is an OP 177B operator panel belonging to the SIMATIC HMI series, designed for machine-level human-machine interface applications. This unit provides a compact and robust operator interface solution for monitoring and controlling industrial automation systems. It is part of Siemens' established SIMATIC HMI product line, which is widely used in conjunction with SIMATIC S7 PLCs and other Siemens automation platforms.

    The OP 177B features a 5.7-inch STN display with a resolution of 320 x 240 pixels (QVGA) and supports 256 colors, providing clear visualization of process data and operator screens. The panel includes a membrane keypad with function keys for navigation and control inputs. It supports MPI, PROFIBUS DP, and Ethernet (PROFINET) communication interfaces, enabling flexible integration into existing automation networks. Configuration is performed using Siemens WinCC flexible software, and the unit provides onboard flash memory for project storage.

    The OP 177B is commonly deployed in manufacturing, automotive, food and beverage, and packaging industries where a cost-effective, mid-range HMI panel is required at the machine level. Its compatibility with SIMATIC S7-200, S7-300, and S7-400 PLCs makes it suitable for a broad range of machine control applications. The panel's compact form factor and standard panel-cut mounting make it straightforward to integrate into control cabinet doors and machine enclosures.

    Technical Specifications

    Display Size 5.7 inch
    Display Resolution 320 x 240 pixels (QVGA)
    Display Type STN color LCD
    Display Colors 256 colors
    Input Voltage 24 V DC
    Power Consumption Max. 9 W
    Communication Interface MPI, PROFIBUS DP, Ethernet (PROFINET)
    Configuration Software WinCC flexible 2005 or higher
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cUL
    Series SIMATIC HMI OP 177B

    Common Error Codes & System Events

    Event ID: 10000
    Configuration error: The project loaded on the panel contains configuration errors or is incompatible with the firmware version.
    Recompile and re-download the WinCC flexible project ensuring compatibility with the panel firmware version.
    Event ID: 20000
    Communication error: Connection to the configured PLC or controller cannot be established.
    Check communication cable connections, verify MPI/PROFIBUS address settings, and confirm PLC is powered and operational.
    Event ID: 40000
    Tag read error: A configured tag cannot be read from the connected controller.
    Verify the tag address in WinCC flexible matches the actual PLC memory address. Check PLC program for the corresponding data block or variable.
    Event ID: 50000
    Tag write error: A value cannot be written to the configured controller tag.
    Check that the target PLC address is writable and not write-protected. Verify communication link integrity.
    Event ID: 60000
    Flash memory error: An error occurred during read or write access to the internal flash memory.
    Attempt to re-download the project. If the error persists, the internal flash memory may be faulty and the panel may require repair or replacement.
    Event ID: 70000
    System error: Internal system fault detected on the HMI panel.
    Perform a power cycle. If the fault persists, perform a factory reset and re-download the project. Contact Siemens support if unresolved.
    Event ID: 80000
    Printer error: Communication with the configured printer has failed or the printer is unavailable.
    Check printer connection and configuration settings in the WinCC flexible project. Verify printer is powered and online.

    Frequently Asked Questions

    Which configuration software is required for the OP 177B (6AV6344-2AD14-0MF6)?

    The OP 177B is configured using Siemens WinCC flexible 2005 or later versions. Projects are compiled in WinCC flexible and downloaded to the panel via MPI, PROFIBUS, or Ethernet connection.

    Which PLCs are compatible with the Siemens OP 177B?

    The OP 177B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs, as well as other Siemens controllers supported by WinCC flexible. Third-party controllers with supported communication drivers may also be connected.

    What communication interfaces does the 6AV6344-2AD14-0MF6 support?

    This panel supports MPI, PROFIBUS DP, and Ethernet (PROFINET) communication interfaces, allowing integration into a variety of Siemens automation network architectures.

    What is the supply voltage for the OP 177B?

    The OP 177B requires a 24 V DC power supply. Ensure the supply is within the specified tolerance range as defined in the Siemens operating instructions.

    What is the front panel protection rating of the OP 177B?

    The front panel of the OP 177B carries an IP65 protection rating, making it suitable for installation in environments where dust and water spray may be present.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power connector. Verify the supply is within the specified range and that the connector is properly seated.

    Restore correct 24 V DC supply. If voltage is correct and display remains blank, inspect internal fuse and power supply circuitry. The panel may require repair or replacement of the internal power supply board.

    HMI panel fails to communicate with the PLC

    Verify the communication cable type and wiring for MPI or PROFIBUS. Check that the bus address configured on the panel matches the network configuration. Confirm the PLC is powered and running.

    Correct any wiring faults, set the correct MPI or PROFIBUS address in the panel settings, and ensure termination resistors are properly placed at both ends of the bus. Re-download the WinCC flexible project if communication parameters were changed.

    Touchscreen or keypad inputs are not responding

    Check whether the panel is in transfer mode or displaying a system screen that prevents normal operation. Verify that the project is correctly loaded and running.

    Restart the panel and allow the project to load fully. If keypad keys are physically damaged or unresponsive, the membrane keypad assembly may need replacement.

    Project download fails or transfer is interrupted

    Check the transfer cable connection between the engineering PC and the panel. Verify that the panel is set to transfer mode and that the correct communication interface is selected in WinCC flexible.

    Ensure the panel is in transfer mode before initiating download. Use a known-good MPI or Ethernet cable. Confirm firewall or antivirus software on the PC is not blocking the WinCC flexible transfer process.

    Display shows distorted or incorrect colors

    Inspect the display for physical damage. Check if the issue is consistent across all screens or only on specific project screens, which may indicate a configuration issue rather than a hardware fault.

    If the distortion is hardware-related, the LCD module may require replacement. If the issue is screen-specific, review the graphic and color configuration in the WinCC flexible project and re-download.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart