• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6344-2AD14-0CF6 OP 177B
    Awaiting product image

    Siemens 6AV6344-2AD14-0CF6 OP 177B

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6344-2AD14-0CF6 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6344-2AD14-0CF6 is an OP 177B operator panel belonging to the SIMATIC HMI family, designed for machine-level human-machine interface applications. This unit provides a monochrome or color display with touch and key-based operation, serving as a compact and robust interface for industrial control systems. It is part of Siemens' mid-range HMI portfolio, positioned between basic text panels and full-featured PC-based systems.

    The OP 177B features a 5.7-inch STN display and supports both MPI/PROFIBUS DP and Ethernet communication interfaces, enabling flexible integration into SIMATIC S7 environments. It is configured using WinCC flexible engineering software and supports recipe management, trend displays, alarm logging, and user administration functions. The unit operates on 24 V DC supply and is built to IP65 protection rating on the front panel, making it suitable for demanding industrial environments.

    The OP 177B is widely deployed in manufacturing, process automation, and machine building applications where a compact, reliable operator interface is required. It is commonly found on packaging machinery, conveyor systems, injection molding machines, and general-purpose industrial equipment. Its compatibility with the SIMATIC S7-300 and S7-400 controller families makes it a standard choice for Siemens-based automation architectures.

    Technical Specifications

    Display Size 5.7 inch
    Display Type STN LCD
    Display Colors 256 colors
    Display Resolution 320 x 240 pixels (QVGA)
    Touch Technology Resistive touchscreen with membrane keypad
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 12 W
    Communication Interface MPI/PROFIBUS DP, RS-422/RS-485, Ethernet (RJ45)
    IP/Protection Rating IP65 (front), IP20 (rear)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90%, non-condensing
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC HMI OP 177B

    Common Error Codes & System Events

    Event ID: 10000
    Configuration error detected during startup; the project loaded on the device is incompatible or corrupted.
    Re-transfer the project using WinCC flexible. Verify the project was compiled without errors before transfer.
    Event ID: 20000
    Communication error with the configured PLC controller; connection to the SIMATIC S7 controller has been lost.
    Check MPI/PROFIBUS DP or Ethernet cabling and termination resistors. Verify PLC address settings match the HMI project configuration.
    Event ID: 40000
    Operating system error; the device firmware or OS has encountered an internal fault.
    Perform a device reset. If the error persists, update the firmware using ProSave or WinCC flexible.
    Event ID: 50000
    Memory error; insufficient memory available to load or run the configured project.
    Reduce project size, optimize graphics and scripts, or clear unused data from the device memory before reloading the project.
    Event ID: 60000
    Tag update error; one or more process tags cannot be read or written to the connected controller.
    Verify tag addresses in the WinCC flexible project match the PLC data block structure. Check communication link status.
    Event ID: 70000
    Recipe data error; recipe records cannot be read from or written to the configured storage location.
    Check available memory on the device or external memory card. Verify recipe configuration in WinCC flexible is correct.
    System Event: RTC Fault
    Real-time clock battery is low or the internal clock has lost its settings after a power interruption.
    Replace the internal backup battery. Reconfigure the date and time settings on the device after battery replacement.

    Frequently Asked Questions

    What engineering software is required to configure the OP 177B?

    The OP 177B is configured using Siemens WinCC flexible 2008 or later. Projects are compiled and transferred to the device via MPI, PROFIBUS DP, Ethernet, or USB connection.

    Which Siemens PLC families are compatible with the OP 177B?

    The OP 177B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs, as well as SIMATIC WinAC controllers. Communication is supported via MPI, PROFIBUS DP, and Ethernet protocols.

    What is the front panel protection rating of the 6AV6344-2AD14-0CF6?

    The front panel of the OP 177B carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets. The rear of the unit is rated IP20.

    Can the OP 177B display process trends and alarms?

    Yes, the OP 177B supports trend displays, alarm logging with acknowledgment, and alarm history functions. These features are configured within the WinCC flexible project.

    What supply voltage does the OP 177B require?

    The OP 177B operates on a 24 V DC supply voltage. The power consumption is a maximum of 12 W under normal operating conditions.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the power connector on the rear of the unit. Check for blown internal fuses and verify the power supply output is within tolerance.

    Restore the 24 V DC supply to within specification. If the supply is correct and the display remains blank, the internal power supply board or backlight inverter may require replacement.

    HMI fails to establish communication with the PLC

    Check the MPI or PROFIBUS DP cable connections and verify that bus termination resistors are correctly installed at both ends of the network. Confirm that the HMI station address and baud rate match the PLC network settings.

    Correct any address conflicts or baud rate mismatches in the WinCC flexible project and re-transfer. Replace damaged cables or connectors as necessary.

    Touchscreen does not respond or responds inaccurately

    Attempt to recalibrate the touchscreen through the device's Control Panel settings accessible during startup. Check for physical damage or contamination on the touch surface.

    Perform a touchscreen calibration via the SIMATIC HMI Control Panel. If calibration does not resolve the issue, the touchscreen overlay may need to be replaced.

    Project transfer fails via Ethernet or MPI

    Verify the IP address or MPI address configured in WinCC flexible matches the device settings. Check that the PC and HMI are on the same network segment and that no firewall is blocking the transfer port.

    Correct the communication settings in WinCC flexible and on the device. Ensure the correct transfer channel is enabled on the HMI via the Control Panel transfer settings.

    Device repeatedly restarts or shows a white screen on boot

    This may indicate a corrupted project or firmware issue. Attempt to boot the device into the Transfer mode by holding the appropriate key combination during startup to bypass the loaded project.

    Re-transfer a valid compiled project using WinCC flexible. If the issue persists, perform a firmware update using ProSave to restore the operating system to a known good state.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart