• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6344-2AD04-0MG7 OP 177B
    Awaiting product image

    Siemens 6AV6344-2AD04-0MG7 OP 177B

    € 2.495,00

    Reset
    Clear
    SKU: 6AV6344-2AD04-0MG7 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6344-2AD04-0MG7 is an OP 177B operator panel belonging to the SIMATIC HMI family, designed for machine-level visualization and operator control in industrial automation environments. This unit features a monochrome STN LCD display and is part of the Comfort/Advanced panel generation that bridges basic text-based operation with graphical display capabilities. It is configured for use with Siemens SIMATIC controllers and is programmed using WinCC flexible engineering software.

    The OP 177B 6AV6344-2AD04-0MG7 provides a 5.7-inch monochrome display with a resolution of 320 x 240 pixels and includes a membrane keypad with function keys for operator input. It supports MPI and PROFIBUS DP communication interfaces for direct connection to SIMATIC S7-200, S7-300, and S7-400 PLCs, as well as third-party controllers via configurable drivers. The panel offers 512 KB user memory for project data, supports alarm logging, recipe management, and trend display functions, and operates on a 24 V DC supply.

    The OP 177B is widely deployed in machine building, packaging machinery, conveyor systems, and process plant control panels where a compact, robust operator interface is required. Its membrane keypad design makes it suitable for environments with dust and moisture exposure, and its PROFIBUS DP connectivity allows integration into distributed automation architectures. The panel is commonly found in applications where cost-effective, reliable HMI functionality is needed without the requirement for a full touchscreen interface.

    Technical Specifications

    Display Size 5.7 inch
    Display Type Monochrome STN LCD
    Display Resolution 320 x 240 pixels
    Input Type Membrane keypad with function keys
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 8 W
    Communication Interface MPI, PROFIBUS DP
    User Memory 512 KB
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Engineering Software WinCC flexible 2005 or higher

    Common Error Codes & System Events

    Event ID: 10000
    Connection to the PLC could not be established or was interrupted during operation.
    Check MPI or PROFIBUS DP cable connections, verify PLC address settings, and confirm the PLC is powered and in RUN mode.
    Event ID: 10001
    Communication timeout between the HMI panel and the configured controller.
    Verify network cable integrity, check baud rate settings on both the panel and PLC, and ensure no address conflicts exist on the bus.
    Event ID: 20000
    Project download failed or project data is corrupted.
    Re-download the project from WinCC flexible, check USB or serial transfer cable, and verify sufficient user memory is available.
    Event ID: 40000
    Recipe data error — recipe record could not be read or written.
    Check recipe configuration in WinCC flexible, verify memory availability, and re-download the project if recipe structure has changed.
    Event ID: 50000
    System startup error — panel failed to load the runtime project on boot.
    Perform a panel reset, re-download the project, and check for corrupted project files in WinCC flexible.
    Event ID: 60000
    Alarm buffer overflow — the number of pending alarms exceeds the configured buffer size.
    Acknowledge and clear active alarms, increase the alarm buffer size in the WinCC flexible project configuration, and re-download.
    Event ID: 70000
    Internal device error or hardware fault detected during self-test.
    Perform a factory reset of the panel. If the fault persists, the unit may require repair or replacement of internal components.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 177B 6AV6344-2AD04-0MG7?

    The OP 177B is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP. Third-party controllers can also be connected using available communication drivers configured in WinCC flexible.

    What software is required to program the OP 177B?

    The OP 177B is programmed using Siemens WinCC flexible 2005 or a later version. Projects are transferred to the panel via MPI, PROFIBUS DP, or a serial PC/PPI cable.

    What is the display type on this operator panel?

    The 6AV6344-2AD04-0MG7 features a 5.7-inch monochrome STN LCD with a resolution of 320 x 240 pixels. It does not have a touchscreen; operator input is via the integrated membrane keypad.

    What is the supply voltage for the OP 177B?

    The panel operates on a 24 V DC supply voltage. Ensure a stable, regulated 24 V DC power source is used to avoid operational issues.

    What is the IP protection rating of the OP 177B front panel?

    The front face of the OP 177B achieves IP65 protection, making it resistant to dust ingress and low-pressure water jets, suitable for typical industrial panel door mounting.

    Troubleshooting

    Display remains blank after power on

    Measure 24 V DC at the power supply connector on the rear of the panel. Check the internal fuse and verify the power supply unit is providing stable voltage.

    Replace the 24 V DC power supply if voltage is absent or unstable. If voltage is correct but display remains blank, the internal power supply board or backlight may require replacement.

    Panel displays 'No connection to PLC' message

    Check the MPI or PROFIBUS DP cable between the panel and the PLC. Verify the bus address configured on the panel matches the project settings and that no address conflicts exist.

    Replace or reseat the communication cable, correct the bus address in the panel startup settings, and confirm the PLC is powered and in RUN mode. Re-download the project if settings were changed.

    Panel freezes or becomes unresponsive during operation

    Determine whether the freeze is reproducible under specific conditions such as alarm bursts or recipe operations. Check available user memory and project complexity.

    Perform a panel reset by cycling power. If the issue recurs, optimize the WinCC flexible project to reduce polling cycles and alarm frequency, then re-download the project.

    Project download fails from WinCC flexible

    Verify the PC-to-panel connection cable is functional and the correct communication port and transfer settings are selected in WinCC flexible. Check that the panel is in transfer mode.

    Place the panel in transfer mode via the Start Center menu, select the correct interface in WinCC flexible, and retry the download. Replace the transfer cable if communication errors persist.

    Function keys do not respond to presses

    Inspect the membrane keypad for physical damage, contamination, or deformation. Verify that the key functions are correctly configured in the WinCC flexible project.

    Clean the keypad surface and check for mechanical damage. If individual keys are non-functional due to membrane wear, the keypad membrane assembly requires replacement.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart