• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6344-2AC34-0CG7 OP177B
    Awaiting product image

    Siemens 6AV6344-2AC34-0CG7 OP177B

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6344-2AC34-0CG7 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6344-2AC34-0CG7 is an OP177B operator panel belonging to the SIMATIC HMI series, designed for machine-level human-machine interface applications. This unit provides a monochrome display with keypad-based operation, enabling operators to monitor and control industrial processes without requiring a touchscreen interface. As part of the SIMATIC HMI comfort and basic panel lineage, it is engineered for integration with Siemens SIMATIC S7 and other compatible PLC families.

    The OP177B features a 5.7-inch STN monochrome display and supports communication via MPI, PROFIBUS DP, and Ethernet interfaces, allowing flexible integration into existing automation networks. It runs the WinCC flexible runtime environment and offers onboard flash memory for project storage, supporting a substantial number of tags, screens, and alarm messages. The panel operates on 24 V DC supply and is rated to IP65 at the front face, providing protection against dust and water ingress in demanding industrial environments.

    The OP177B is widely deployed in manufacturing, automotive, food and beverage, and process industries where robust operator control stations are required at the machine level. Its keypad-based design makes it suitable for environments where touchscreen operation is impractical due to gloves, contamination, or vibration. The panel is commonly mounted in control cabinet doors or operator consoles and is used to visualize process data, manage alarms, and configure machine parameters.

    Technical Specifications

    Display Size 5.7 inch
    Display Type STN monochrome
    Display Colors Monochrome (blue/white)
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 9 W
    Communication Interface MPI, PROFIBUS DP, Ethernet (RJ45)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP/Protection Rating IP65 (front), IP20 (rear)
    Mounting Panel mounting
    Series/Product Family SIMATIC HMI OP177B
    Certifications CE, UL, cULus
    Control Type Keypad (membrane keys)

    Common Error Codes & System Events

    Event ID: 1000
    Communication error between the HMI panel and the connected PLC or controller.
    Check MPI/PROFIBUS/Ethernet cable connections and verify the configured communication parameters (station address, baud rate) match the PLC settings.
    Event ID: 10000
    Project download failed or project data is corrupted on the panel.
    Re-download the WinCC flexible project to the panel via ProSave or WinCC flexible. Ensure the project version is compatible with the panel firmware.
    Event ID: 20000
    Internal flash memory error or insufficient memory for project storage.
    Delete unused projects or data from the panel memory. If the error persists, perform a factory reset and re-download the project.
    Event ID: 40000
    Firmware update error or firmware version mismatch detected.
    Use ProSave to update the panel firmware to the correct version compatible with the WinCC flexible project. Ensure stable power supply during the update process.
    Event ID: 2000
    Tag or variable connection lost; the HMI cannot read or write the configured PLC tag.
    Verify the PLC program contains the configured tag addresses. Check for PLC faults or program stops that may prevent communication.
    Event ID: 50000
    System startup error; the panel fails to boot correctly into the runtime environment.
    Perform a panel reset by holding the appropriate key combination during startup. If unsuccessful, use ProSave to restore the operating system and re-download the project.
    Event ID: 30000
    Recipe data error; recipe records cannot be read from or written to the panel memory.
    Check recipe configuration in WinCC flexible for consistency. Clear recipe data on the panel and re-transfer recipe records from the engineering station.

    Frequently Asked Questions

    What communication interfaces does the OP177B (6AV6344-2AC34-0CG7) support?

    The OP177B supports MPI, PROFIBUS DP, and Ethernet (RJ45) communication interfaces, allowing connection to SIMATIC S7-200, S7-300, S7-400, and other compatible controllers.

    What software is used to configure and program this panel?

    The OP177B is configured using Siemens WinCC flexible engineering software. Projects are transferred to the panel via Ethernet, MPI, or USB using the ProSave tool.

    What is the supply voltage for the 6AV6344-2AC34-0CG7?

    The panel requires a 24 V DC power supply. Ensure the supply is within the specified tolerance range to prevent damage or malfunction.

    Is the OP177B compatible with SIMATIC S7-1200 or S7-1500 PLCs?

    The OP177B is primarily designed for use with S7-200, S7-300, and S7-400 PLCs via WinCC flexible. Compatibility with S7-1200 and S7-1500 is limited; TIA Portal-based panels are recommended for those controllers.

    What is the front panel protection rating of the 6AV6344-2AC34-0CG7?

    The front face of the OP177B is rated IP65, providing full protection against dust and protection against low-pressure water jets, making it suitable for industrial environments.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the power connector on the rear of the panel. Check for blown internal fuses or incorrect polarity on the supply connection.

    Correct the supply voltage or polarity. If the supply is confirmed good and the display remains blank, the internal power supply board or backlight may require replacement.

    Panel fails to communicate with the PLC

    Verify the communication cable type and wiring (MPI, PROFIBUS, or Ethernet). Check that the station address and baud rate configured in WinCC flexible match the PLC settings exactly.

    Correct any address or baud rate mismatches in the WinCC flexible project and re-download. Replace the communication cable if continuity testing reveals a fault.

    Panel continuously reboots or shows a loader screen on startup

    This typically indicates a corrupted operating system or project file on the panel flash memory. Attempt to access the panel via ProSave during the boot sequence.

    Use ProSave to perform an operating system update (OS update) to restore the panel firmware, then re-download the WinCC flexible project.

    Keypad buttons are unresponsive or intermittently register inputs

    Inspect the membrane keypad for physical damage, contamination, or delamination. Check the internal ribbon cable connection between the keypad membrane and the main board.

    Clean the keypad surface. If the ribbon cable is loose or damaged, reseat or replace it. In cases of severe membrane damage, replace the keypad membrane assembly.

    Alarm messages are not displayed or alarms are missing

    Check the alarm configuration in the WinCC flexible project to ensure alarm tags are correctly linked to PLC addresses. Verify the PLC program is setting the correct alarm bits.

    Correct the alarm tag addresses in the WinCC flexible project and re-download. Confirm the PLC logic is functioning correctly and writing to the expected memory addresses.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart