• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6344-2AC24-0MG7 OP 177B
    Awaiting product image

    Siemens 6AV6344-2AC24-0MG7 OP 177B

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6344-2AC24-0MG7 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6344-2AC24-0MG7 is an Operator Panel (OP 177B) belonging to the SIMATIC HMI series, designed for machine-level human-machine interface applications. This unit provides a monochrome or color display with touch and key-based operation, serving as a compact yet capable panel for process visualization and control. It is part of Siemens' established SIMATIC HMI product line, offering reliable performance in industrial environments.

    The OP 177B features a 5.7-inch STN display and supports both MPI/PROFIBUS DP and Ethernet (PROFINET) communication interfaces, enabling flexible integration into existing Siemens automation architectures. The panel is configured using WinCC flexible engineering software and supports scripting, alarm management, recipe handling, and trend displays. It operates on 24 V DC supply and is rated to IP65 on the front face, providing protection against dust and water ingress in panel-mounted installations.

    The OP 177B is widely deployed in manufacturing, packaging, food and beverage, and general machine automation applications where a compact operator interface is required. Its compatibility with SIMATIC S7-200, S7-300, and S7-400 PLCs makes it a versatile choice for retrofitting or new installations. The combination of key-based and optional touch operation suits environments where gloved operation or robust input methods are preferred.

    Technical Specifications

    Display Size 5.7 inch
    Display Type STN LCD
    Display Colors 256 colors
    Display Resolution 320 x 240 pixels (QVGA)
    Touch Technology Resistive touchscreen (touch variant)
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 9 W
    Communication Interface MPI/PROFIBUS DP, Ethernet (PROFINET), USB
    Configuration Software WinCC flexible 2008 or later
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC. The panel cannot establish or maintain a connection.
    Check MPI/PROFIBUS DP or Ethernet cable connections and termination resistors. Verify PLC address settings and communication parameters in WinCC flexible project match the hardware configuration.
    Event ID: 10001
    Connection to the configured PLC has been interrupted during runtime.
    Inspect physical communication cables for damage. Confirm PLC is powered and running. Check for address conflicts on the network and verify baud rate settings.
    Event ID: 20000
    Project download error. The configuration project could not be transferred to the panel successfully.
    Ensure the correct communication interface is selected in WinCC flexible transfer settings. Verify the panel is in transfer mode and that the PC and panel are connected via USB or Ethernet.
    Event ID: 40000
    System memory low. The panel's available runtime memory is insufficient for the loaded project.
    Reduce the number of active alarms, trends, or recipe data sets in the project. Optimize the WinCC flexible project to reduce memory usage and re-download to the panel.
    Event ID: 50000
    Internal device error detected. A hardware fault has been identified within the panel.
    Perform a panel restart. If the error persists, back up the project, perform a factory reset, and reload the project. Contact Siemens technical support if the fault continues.
    Event ID: 70000
    Configuration error. The loaded project contains settings incompatible with the current panel firmware version.
    Update the panel firmware to the version compatible with the WinCC flexible project version. Re-download the project after firmware update.
    Event ID: 30000
    Tag read/write error. A configured variable (tag) could not be read from or written to the PLC.
    Verify the PLC data block addresses referenced in the HMI project exist and are accessible. Check PLC program for address changes and update the HMI project accordingly.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 177B (6AV6344-2AC24-0MG7)?

    The OP 177B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It also supports PROFINET communication for connection to S7-300/400 controllers with Ethernet capability.

    What software is required to configure and program the OP 177B?

    The OP 177B is configured using Siemens WinCC flexible 2008 or a compatible version. Projects are transferred to the panel via USB or Ethernet connection.

    What is the supply voltage for the 6AV6344-2AC24-0MG7?

    The panel operates on a 24 V DC supply voltage. Ensure the power supply can deliver sufficient current, typically up to 0.5 A at 24 V DC.

    Is the OP 177B front panel rated for wash-down or dusty environments?

    Yes, the front face of the OP 177B carries an IP65 protection rating, making it suitable for environments with dust and water spray. The rear of the unit is rated IP20.

    Can the OP 177B be used as a replacement for older Siemens OP panels?

    The OP 177B can serve as a functional replacement for older SIMATIC HMI panels such as the OP 17 and OP 27, provided the WinCC flexible project is adapted to the new panel type and communication settings are reconfigured accordingly.

    Troubleshooting

    Display remains blank after power is applied

    Measure 24 V DC at the power supply connector on the rear of the panel. Check the internal fuse if accessible. Verify the power supply unit can deliver adequate current.

    Replace the power supply if voltage is absent or out of tolerance. If voltage is correct but display remains blank, the backlight or internal display board may have failed and the panel will require repair or replacement.

    Panel displays 'Connecting…' and fails to communicate with the PLC

    Check the MPI/PROFIBUS DP cable connections at both the panel and PLC ends. Verify bus termination is correctly applied at both ends of the network. Confirm the panel's configured PLC address matches the actual PLC address.

    Replace or reseat communication cables. Correct bus termination using appropriate resistors or termination plugs. Update the HMI project communication settings in WinCC flexible and re-download to the panel.

    Touchscreen does not respond or responds inaccurately to touch input

    Check whether the touchscreen responds at all by testing multiple areas of the screen. Determine if the issue is a complete failure or a calibration drift. Access the panel's system menu to attempt touchscreen recalibration.

    Perform a touchscreen calibration via the panel's Start Center or Control Panel menu. If calibration does not resolve the issue, the touchscreen overlay may be damaged and require replacement.

    Panel repeatedly reboots or freezes during operation

    Check the 24 V DC supply for voltage dips or instability under load. Review the active alarm log for system memory or internal error events. Verify the WinCC flexible project is not overloading the panel's CPU with excessive tag polling rates.

    Stabilize the power supply and ensure adequate current capacity. Optimize the HMI project by reducing tag update cycles and unnecessary graphical elements. If the problem persists, perform a firmware update or factory reset and reload the project.

    Project transfer from PC to panel fails

    Confirm the panel is set to transfer mode via the Start Center. Check the USB or Ethernet cable connection between the PC and panel. Verify that the WinCC flexible project is configured for the correct panel type and communication interface.

    Switch the panel to transfer mode manually through the Start Center menu. Replace the USB cable if faulty. Ensure the PC firewall is not blocking the WinCC flexible transfer process. Match the project panel type to the physical hardware before retrying the transfer.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart