Siemens 6AV6343-3AA04-0MB6 OP 177B
€ 1.995,00
The Siemens 6AV6343-3AA04-0MB6 is an Operator Panel (OP 177B) belonging to the SIMATIC HMI series, designed for machine-level human-machine interface applications. This unit provides a monochrome STN display with a physical keypad for operator interaction, and is part of the established SIMATIC HMI comfort and basic panel lineup. It is configured for use with Siemens STEP 7 and WinCC flexible engineering software, enabling straightforward integration into Siemens automation environments.
The OP 177B features a 5.7-inch STN LCD display with a resolution of 320 x 240 pixels and supports up to 256 colors in its color variants, though this specific unit is a monochrome version. It is equipped with MPI/PROFIBUS DP and RS-422/RS-485 interfaces for PLC communication, along with a USB port for project transfer and data backup. The panel operates on 24 V DC supply voltage and includes a membrane keypad with function keys, system keys, and numeric/alphanumeric input capability. Onboard flash memory supports project storage, and the unit is rated for industrial environments with an IP65 protection rating on the front face.
The OP 177B is widely deployed in manufacturing, packaging, and process automation applications where a robust, keypad-operated interface is preferred over touchscreen operation. It is particularly suited for machine tool panels, conveyor systems, and production line control stations where operators require reliable tactile feedback. Its compatibility with SIMATIC S7-200, S7-300, and S7-400 PLCs makes it a versatile choice across a broad range of Siemens-based automation installations.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Type | STN LCD (monochrome) |
| Display Resolution | 320 x 240 pixels (QVGA) |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 9 W |
| Communication Interface | MPI/PROFIBUS DP, RS-422/RS-485, USB |
| IP Protection Rating (Front) | IP65 |
| IP Protection Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC HMI OP 177B |
| Certifications | CE, UL, cULus |
| Engineering Software | WinCC flexible 2008 / STEP 7 |
Common Error Codes & System Events
- Event ID: 10000
- Configuration error detected during startup — project data on the device is missing or corrupted.
Re-transfer the WinCC flexible project to the panel via USB or MPI connection and restart the device. - Event ID: 10001
- Communication connection to the configured PLC has failed or cannot be established.
Check MPI/PROFIBUS DP cable connections, verify bus address settings, and confirm the PLC is powered and in RUN mode. - Event ID: 20000
- System memory low — available memory for runtime operation is insufficient.
Reduce the project size, remove unused screens or tags, and re-transfer the optimized project to the panel. - Event ID: 40000
- Tag read/write error — a configured variable could not be read from or written to the PLC.
Verify the PLC data block and address assignments in WinCC flexible match the actual PLC program. Check for address conflicts. - Event ID: 50000
- Printer communication error — the panel cannot communicate with the configured printer.
Check printer cable connections and printer power. Verify printer settings in the WinCC flexible project configuration. - Event ID: 70000
- Recipe data error — recipe records could not be read or written correctly.
Check available flash memory on the device. Re-transfer recipe data and verify recipe configuration in WinCC flexible. - Event ID: 110000
- Operating system error — an internal system fault has occurred during runtime.
Perform a controlled restart of the panel. If the fault persists, perform a factory reset and re-transfer the project.
Frequently Asked Questions
Which PLCs are compatible with the OP 177B (6AV6343-3AA04-0MB6)?
The OP 177B is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP. It also supports communication with S7-1200 in some configurations using appropriate drivers in WinCC flexible.
What engineering software is required to program this panel?
The OP 177B is configured using Siemens WinCC flexible 2008 or later. Projects are transferred to the panel via USB or MPI/PROFIBUS DP connection.
What is the supply voltage for the 6AV6343-3AA04-0MB6?
The panel requires a 24 V DC power supply. Ensure the supply is within the permissible tolerance range as specified in the device manual.
Does the OP 177B support touchscreen input?
No, the OP 177B uses a membrane keypad with function keys, system keys, and alphanumeric input keys. It does not have a touchscreen interface.
What is the front panel protection rating of this unit?
The front panel of the OP 177B carries an IP65 protection rating, making it suitable for installation in environments where dust and water jets may be present.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector. Verify the supply is within tolerance and the connector is fully seated. Inspect for any blown internal fuse.
Ensure the 24 V DC supply is stable and correctly wired. If the supply is confirmed good and the display remains blank, the internal power supply board or backlight may require replacement.
Panel fails to communicate with the PLC
Verify the MPI or PROFIBUS DP cable is correctly connected and terminated. Check that the bus address configured on the panel matches the project settings and does not conflict with other nodes.
Correct any address conflicts, ensure proper bus termination at both ends of the cable, and confirm the PLC is in RUN mode. Re-transfer the project if communication parameters have changed.
Project transfer via USB fails or is not recognized
Check that the USB cable is a standard USB A-to-B or A-to-Mini-B type as required. Verify the PC has the correct Siemens USB driver installed for the panel.
Install or reinstall the Siemens HMI USB driver on the engineering PC. Try a different USB cable or port. Ensure WinCC flexible is at the correct version for this panel.
Touchkeys or function keys are unresponsive
Inspect the membrane keypad for physical damage, contamination, or deformation. Check if the issue is isolated to specific keys or affects all keys.
Clean the keypad surface with a dry cloth. If individual keys are permanently unresponsive due to membrane damage, the keypad membrane assembly will need to be replaced.
Panel continuously reboots or displays a startup error loop
This typically indicates a corrupted or incompatible project file stored on the device, or a hardware fault with the flash memory.
Perform a factory reset by accessing the panel's loader menu during startup. Re-transfer a compatible WinCC flexible project. If the issue persists after reset, the flash memory module may need replacement.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page