Siemens 6AV6343-0AA04-0MB6 OP 177B
€ 1.995,00
The Siemens 6AV6343-0AA04-0MB6 is an Operator Panel (OP 177B) belonging to the SIMATIC HMI series, designed for machine-level human-machine interface applications. This unit provides a monochrome display with keypad-based operation and is part of Siemens' mid-range HMI panel lineup. It is configured for use with PROFIBUS and MPI communication, enabling direct integration into SIMATIC automation environments.
The OP 177B features a 5.7-inch STN monochrome display with a resolution of 320 x 240 pixels and supports up to 4 grey scales. It is equipped with MPI/PROFIBUS DP and RS-422/RS-485 interfaces for PLC connectivity, along with a USB port for project transfer and data backup. The panel operates on 24 V DC supply voltage and includes a membrane keypad with function keys for operator input. Configuration is performed using WinCC flexible software, and the unit supports recipe management, alarm logging, and trend display functions.
The OP 177B is widely used in manufacturing, machine building, and process automation environments where a robust, keypad-operated interface is preferred over touchscreen operation. It is particularly suited for applications in harsh industrial environments where gloved operation or high-vibration conditions make physical keys more practical than touch input. Typical installations include packaging machinery, conveyor systems, and general-purpose machine control panels.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Type | STN monochrome LCD |
| Display Resolution | 320 x 240 pixels |
| Display Colors | 4 grey scales |
| Input Voltage | 24 V DC |
| Power Consumption | Max. 9 W |
| Communication Interface | MPI/PROFIBUS DP, RS-422/RS-485, USB |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Mounting | Panel mounting |
| Configuration Software | WinCC flexible 2008 or later |
| Series/Product Family | SIMATIC HMI OP 177B |
Common Error Codes and System Events
- Event ID: 10000
- Communication error between the HMI panel and the connected PLC via MPI or PROFIBUS DP.
Check MPI/PROFIBUS cable connections and termination resistors. Verify the PLC address settings match the HMI project configuration. Ensure the PLC is in RUN mode. - Event ID: 10001
- Connection to the PLC was interrupted during runtime.
Inspect the communication cable for damage. Check bus termination and cable shielding. Restart the HMI panel and verify PLC communication parameters. - Event ID: 20000
- Project download failed or project data is corrupted.
Re-transfer the project using WinCC flexible via USB or MPI. Ensure the project is compiled without errors before transfer. - Event ID: 40000
- Internal device error or hardware fault detected.
Perform a power cycle. If the error persists, back up the project and perform a factory reset. Contact Siemens support if the fault recurs. - Event ID: 50000
- Tag value exceeds the configured high or low limit.
Check the PLC data source for the affected tag. Verify limit values configured in the HMI project are appropriate for the process range. - Event ID: 60000
- Recipe data error — recipe record could not be read or written.
Check available memory on the panel. Verify recipe configuration in WinCC flexible. Re-transfer the project if recipe data is corrupted. - Event ID: 70000
- Alarm buffer overflow — the alarm log is full.
Archive or clear the alarm buffer. Increase the configured alarm buffer size in the WinCC flexible project settings if possible.
Frequently Asked Questions
What communication interfaces does the OP 177B (6AV6343-0AA04-0MB6) support?
The OP 177B supports MPI and PROFIBUS DP communication via an RS-422/RS-485 interface, as well as a USB port used for project transfer and data backup.
Which software is used to configure and program the OP 177B?
The OP 177B is configured using Siemens WinCC flexible 2008 or a compatible version. Projects are transferred to the panel via USB or MPI connection.
Is the OP 177B compatible with SIMATIC S7-300 and S7-400 PLCs?
Yes, the OP 177B is designed for direct integration with SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS DP, and can also communicate with S7-200 PLCs via RS-485.
What is the front panel protection rating of the OP 177B?
The front panel of the OP 177B carries an IP65 protection rating, making it suitable for installation in environments where dust and water spray may be present.
Does the OP 177B support touchscreen input?
No, the OP 177B is a keypad-operated panel and does not feature a touchscreen. Operator input is performed via the integrated membrane keypad and function keys.
Troubleshooting
Display remains blank after power on
Measure the 24 V DC supply voltage at the power connector on the rear of the panel. Check the supply cable and connector for damage or loose connections.
Ensure the 24 V DC supply is within the specified tolerance. If voltage is correct and the display remains blank, the internal power supply or backlight may have failed and the unit should be sent for repair or replacement.
HMI panel fails to communicate with the PLC
Check the MPI or PROFIBUS DP cable connections at both the panel and PLC ends. Verify bus termination is correctly applied at both ends of the network segment. Confirm the PLC address in the HMI project matches the physical PLC configuration.
Replace or reseat the communication cable. Correct any address mismatches in the WinCC flexible project and re-transfer. Ensure only the two physical end nodes have bus termination resistors active.
Project transfer via USB fails or is not recognized
Check that the USB cable is a standard USB A-to-B type and is fully seated. Verify the panel is in transfer mode before initiating the download from WinCC flexible.
Switch the panel to transfer mode via the Start Center menu. Try a different USB cable or port. Ensure the WinCC flexible version is compatible with the panel firmware version.
Operator keys are unresponsive or intermittently fail
Inspect the membrane keypad surface for physical damage, contamination, or deformation. Test each key systematically using the panel's built-in key test function in the Start Center.
Clean the keypad surface with a dry cloth. If individual keys are permanently unresponsive, the membrane keypad assembly may need to be replaced by a qualified technician.
Panel repeatedly restarts or enters an error loop on startup
Attempt to access the Start Center by pressing the appropriate key combination during boot. Check whether the installed project is corrupted or incompatible with the panel firmware version.
Boot into the Start Center and delete the current project, then re-transfer a freshly compiled project from WinCC flexible. If the panel continues to restart without a project loaded, a firmware update or hardware repair may be required.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page