• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6341-1EC04-0AY0 OP 27
    Awaiting product image

    Siemens 6AV6341-1EC04-0AY0 OP 27

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6341-1EC04-0AY0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6341-1EC04-0AY0 is an Operator Panel (OP 27) belonging to the SIMATIC HMI family, designed for machine-level operator control and monitoring tasks. This unit provides a compact, robust interface for visualizing process data and issuing operator commands in industrial automation environments. It is part of the SIMATIC OP series, which is widely used in conjunction with Siemens SIMATIC S7 and S5 PLCs.

    The OP 27 features a 5.7-inch STN monochrome or blue-mode LCD display with a resolution of 240 x 128 pixels, capable of displaying text and graphics. It is equipped with a membrane keypad for operator input, including function keys and system keys. Communication is supported via MPI (Multi-Point Interface) and PROFIBUS-DP interfaces, enabling direct connection to SIMATIC S7-200, S7-300, and S7-400 controllers. The unit operates on a 24 V DC supply and is rated IP65 on the front panel, providing protection against dust and water jets.

    The OP 27 is commonly deployed in machine tool control, packaging machinery, conveyor systems, and process automation applications. Its compact form factor and membrane keypad make it suitable for environments where touchscreen operation is not required and where robust, reliable operator interaction is essential. The panel is particularly prevalent in retrofit and upgrade projects for existing SIMATIC-based installations across manufacturing and process industries.

    Technical Specifications

    Display Size 5.7 inch
    Display Type STN LCD (monochrome/blue-mode)
    Display Resolution 240 x 128 pixels
    Input Type Membrane keypad
    Function Keys 20 function keys (F1–F20)
    Input/Operating Voltage 24 V DC
    Power Consumption Approx. 8 W
    Communication Interface MPI, PROFIBUS-DP (RS-485)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC HMI OP 27

    Common Error Codes & System Events

    Event ID: 10000
    Configuration error – the project loaded onto the device is incompatible or corrupt.
    Re-transfer a valid, compatible project using ProTool configuration software. Verify the project version matches the firmware version on the OP 27.
    Event ID: 20000
    Communication error – the OP 27 cannot establish a connection to the configured PLC.
    Check MPI or PROFIBUS-DP cable connections and termination resistors. Verify the PLC address and baud rate settings match the OP 27 configuration.
    Event ID: 40000
    System memory overflow – the internal memory is insufficient for the current project or runtime data.
    Reduce the size of the project (number of screens, variables, or alarms) and re-transfer. Check for excessive alarm logging consuming memory.
    Event ID: 50000
    Printer error – a print job could not be completed.
    Check the printer connection and ensure the correct printer driver is configured in the project. Verify the printer is online and has paper.
    Event ID: 60000
    Tag read/write error – a process variable could not be read from or written to the PLC.
    Verify the PLC data block and address referenced in the project exist and are accessible. Check PLC program for correct data area definitions.
    Event ID: 70000
    Firmware update error – firmware transfer to the device was interrupted or failed.
    Repeat the firmware update procedure using the correct firmware version for the OP 27. Ensure a stable serial or MPI connection during transfer.
    Event ID: 80000
    Recipe data error – recipe records could not be read or written correctly.
    Check recipe configuration in the ProTool project. Verify that the PLC data areas assigned to recipe variables are correctly defined and accessible.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 27 (6AV6341-1EC04-0AY0)?

    The OP 27 is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS-DP interfaces. It also supports connection to S5 PLCs via appropriate adapters and configuration.

    What software is used to configure and program the OP 27?

    The OP 27 is configured using Siemens ProTool software. Projects are created on a PC and then transferred to the panel via MPI, PROFIBUS-DP, or a serial connection.

    What is the supply voltage for the 6AV6341-1EC04-0AY0?

    The OP 27 operates on a 24 V DC supply voltage. Ensure the power supply is within the specified tolerance range to avoid operational issues.

    What is the front panel protection rating of the OP 27?

    The front panel of the OP 27 is rated IP65, providing protection against dust ingress and water jets. The rear of the unit is rated IP20.

    Can the OP 27 display graphics as well as text?

    Yes, the OP 27 supports both text and graphical display on its 5.7-inch STN LCD with a resolution of 240 x 128 pixels, allowing the creation of simple process graphics and trend displays.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power connector. Verify the internal fuse and inspect the power supply cable for damage.

    Restore the correct 24 V DC supply. Replace the internal fuse if blown. If the display backlight has failed, the backlight or display assembly may require replacement.

    OP 27 cannot communicate with the PLC

    Verify the MPI or PROFIBUS-DP cable is correctly connected and that bus termination resistors are in place at both ends of the bus. Check that the PLC address and baud rate configured in the OP 27 project match the PLC settings.

    Correct any wiring faults and ensure proper bus termination. Adjust the MPI/PROFIBUS address and baud rate in the ProTool project to match the PLC configuration, then re-transfer the project.

    Membrane keypad keys are unresponsive or intermittent

    Inspect the membrane keypad for physical damage, contamination, or delamination. Check the internal ribbon cable connection between the keypad and the main board.

    Clean the keypad surface if contaminated. If the ribbon cable is loose or damaged, reseat or replace it. If the keypad membrane itself is faulty, replace the keypad assembly.

    Project transfer from PC to OP 27 fails

    Check the serial or MPI cable connection between the PC and the OP 27. Verify that the correct COM port and transfer settings are selected in ProTool. Ensure the OP 27 is in transfer mode.

    Use a known-good transfer cable. Set the OP 27 to transfer mode via the system menu. Confirm the ProTool project settings match the panel type and firmware version before retrying the transfer.

    Alarm messages are not displayed or are displayed incorrectly

    Verify that the alarm tags in the ProTool project are correctly mapped to the PLC data addresses. Check PLC program to confirm alarm bits are being set as expected.

    Correct any incorrect tag address assignments in the ProTool project and re-transfer. Ensure the PLC program logic correctly sets and resets the alarm bits associated with each configured alarm message.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart