• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6341-1DC23-1AY0 OP 27
    Awaiting product image

    Siemens 6AV6341-1DC23-1AY0 OP 27

    Reset

    This product is currently out of stock and unavailable.

    SKU: 6AV6341-1DC23-1AY0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6341-1DC23-1AY0 is an operator panel belonging to the SIMATIC OP 27 series, part of Siemens' established SIMATIC HMI product line. This unit functions as a graphical operator panel designed for machine-level human-machine interface applications, providing operators with process visualization and control capabilities. It is a compact panel-mount device intended for integration into control cabinet doors or operator stations.

    The OP 27 features a monochrome or color STN LCD display with a resolution of 320 x 240 pixels (QVGA), supporting graphical representation of process data, alarms, and trends. The panel includes a membrane keypad with function keys, system keys, and numeric/alphanumeric input capability, eliminating the need for a separate keyboard in many applications. Communication is handled via MPI (Multi-Point Interface) and PROFIBUS-DP interfaces, enabling direct connection to SIMATIC S7-300 and S7-400 PLCs. The unit operates on a 24 V DC supply and is rated to IP65 on the front face for protection against dust and water ingress.

    The SIMATIC OP 27 is widely used in manufacturing automation, process control, and machine building industries where a reliable and compact operator interface is required. It is commonly found on packaging machinery, conveyor systems, press lines, and general-purpose industrial machines. Its compatibility with the SIMATIC S7 controller family and support for ProTool configuration software make it a practical choice for system integrators working within the Siemens automation ecosystem.

    Technical Specifications

    Display Type STN LCD
    Display Resolution 320 x 240 pixels (QVGA)
    Display Size 5.7 inch
    Input Voltage 24 V DC
    Power Consumption Approx. 15 W
    Communication Interface MPI, PROFIBUS-DP
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Mounting Panel mounting
    Certifications CE, UL
    Series SIMATIC OP 27

    Common Error Codes and System Events

    Event ID: 10000
    Communication error between the OP panel and the connected PLC. The panel cannot establish or maintain a connection to the configured controller.
    Check MPI or PROFIBUS-DP cable connections and termination resistors. Verify the PLC address and baud rate settings match the panel configuration. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Connection to the PLC was interrupted during operation.
    Inspect the communication cable for damage or loose connectors. Check for address conflicts on the MPI or PROFIBUS network. Restart both the panel and the PLC if the connection does not recover automatically.
    Event ID: 10002
    Configured tag or variable address not found in the connected PLC.
    Verify that the PLC program contains the data blocks and addresses referenced in the OP 27 project. Re-download the project to the panel using ProTool if addresses have changed.
    Event ID: 20000
    Internal system error on the operator panel. A software or firmware fault has been detected.
    Perform a panel restart. If the error persists, reload the project via ProTool. Consider a factory reset if the panel remains non-functional.
    Event ID: 40000
    Project download error. Transfer of the configuration project to the panel was not completed successfully.
    Check the data transfer cable and PC interface settings. Ensure ProTool is configured with the correct transfer parameters and retry the download.
    Event ID: 50000
    Alarm buffer overflow. The number of pending alarms has exceeded the panel's alarm buffer capacity.
    Acknowledge and clear existing alarms on the panel. Review the alarm configuration in ProTool to reduce unnecessary alarm triggers or increase acknowledgment frequency.
    Event ID: 60000
    Panel operating system or firmware version mismatch with the loaded project.
    Update the panel firmware to the version compatible with the ProTool project version, or recompile and re-download the project using the matching ProTool version.

    Frequently Asked Questions

    Which PLCs are compatible with the SIMATIC OP 27?

    The OP 27 is primarily designed for use with Siemens SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS-DP interfaces. It can also communicate with S5 controllers and third-party devices depending on the communication driver configured in ProTool.

    What software is used to configure the OP 27?

    The OP 27 is configured using Siemens ProTool software. WinCC flexible can also be used in some versions. The project is then transferred to the panel via a PC adapter cable connected to the MPI interface.

    What is the supply voltage for the 6AV6341-1DC23-1AY0?

    The panel operates on a 24 V DC supply voltage. Ensure the power supply can deliver sufficient current, typically around 0.7 A, to power the unit reliably.

    What is the front panel protection rating of the OP 27?

    The front face of the OP 27 is rated to IP65, providing protection against dust ingress and low-pressure water jets. The rear of the unit is rated IP20.

    Can the OP 27 display graphical objects and trend curves?

    Yes, the OP 27 supports graphical display of process values including bar graphs, trend curves, and alarm lists. The 320 x 240 pixel QVGA display allows for structured screen layouts configured in ProTool.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the panel's power connector. Check that polarity is correct and voltage is within the specified range. Inspect the internal fuse if accessible.

    Correct any wiring errors or supply voltage issues. If the supply voltage is confirmed correct and the display remains blank, the internal power supply board or backlight may be faulty and the unit may require repair or replacement.

    Panel displays 'No connection to PLC' or communication error on startup

    Check the MPI or PROFIBUS-DP cable between the panel and PLC. Verify bus termination is correctly applied at both ends of the network. Confirm the PLC node address and baud rate match the panel project settings.

    Replace or reseat the communication cable. Correct address or baud rate mismatches in the ProTool project and re-download. Ensure only one active bus termination exists at each end of the network segment.

    Touchscreen or keypad inputs are not responding correctly

    For membrane keypad issues, inspect the keypad overlay for physical damage or contamination beneath the keys. Verify that the panel project correctly maps function keys to the intended actions.

    Clean the keypad surface. If individual keys are non-responsive due to membrane damage, the keypad overlay or front panel assembly may need replacement. Re-download the project to rule out configuration errors.

    Project download from PC to panel fails or times out

    Check the PC adapter cable connection to the panel's MPI port. Verify the COM port settings in ProTool match the adapter being used. Confirm the panel is in transfer mode.

    Switch the panel to transfer mode via the panel's start menu. Use the correct Siemens PC adapter (e.g., PC Adapter USB or MPI adapter). Reinstall the PC adapter driver if the COM port is not recognized by the PC.

    Alarm messages appear on screen but cannot be acknowledged

    Check whether the alarm requires a PLC bit acknowledgment in addition to operator acknowledgment on the panel. Review the alarm configuration in ProTool for acknowledgment group settings.

    Ensure the PLC program resets the alarm trigger bit after the fault condition is cleared. Reconfigure the alarm acknowledgment type in ProTool if operator-only acknowledgment is intended, then re-download the project.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart