• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6341-1DC04-0AY0 OP 77B
    Awaiting product image

    Siemens 6AV6341-1DC04-0AY0 OP 77B

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6341-1DC04-0AY0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6341-1DC04-0AY0 is an OP 77B operator panel belonging to the SIMATIC HMI Basic Panels product family. It is a compact, key-operated operator panel designed for straightforward machine-level visualization and control tasks. This unit provides a text-based display interface and is part of Siemens' established line of operator panels for industrial automation environments.

    The OP 77B features a 4-line text display capable of showing alphanumeric characters, with dedicated function keys and system keys for operator interaction. It supports MPI and PROFIBUS DP communication interfaces, enabling direct integration with SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel is configured using WinCC flexible software and offers a compact, robust housing suitable for panel door mounting with an IP65 protection rating on the front face.

    The OP 77B is commonly deployed in manufacturing machinery, conveyor systems, packaging equipment, and general industrial automation applications where a cost-effective, reliable operator interface is required. Its compatibility with the SIMATIC S7 PLC family makes it a practical choice for machine builders and system integrators working within the Siemens automation ecosystem. The panel is well-suited for environments where simple status display, parameter input, and alarm acknowledgment are the primary HMI requirements.

    Technical Specifications

    Display Type STN LCD, text-based
    Display Lines 4 lines
    Characters per Line 20 characters
    Communication Interface MPI, PROFIBUS DP
    Input/Operating Voltage 24 V DC
    Power Consumption 4 W (typical)
    IP Protection Rating (Front) IP65
    IP Protection Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Configuration Software WinCC flexible 2005 or higher
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400

    Common Error Codes & System Events

    Event ID: 10000
    Connection to the PLC could not be established or was interrupted during operation.
    Check MPI/PROFIBUS DP cable connections and termination resistors. Verify PLC address settings match the configuration in WinCC flexible. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Communication timeout between the OP 77B and the configured PLC controller.
    Verify network cabling integrity and bus termination. Check that the baud rate configured on the panel matches the PLC network settings. Restart both the panel and the PLC if the issue persists.
    Event ID: 20000
    Project data on the panel is missing or corrupted.
    Re-transfer the project from WinCC flexible to the panel using the configured download interface. Ensure the correct project version is used and the transfer completes without errors.
    Event ID: 20001
    Incompatible project version detected on the panel.
    Open the project in WinCC flexible and verify the target device matches the OP 77B. Re-compile and re-download the project to the panel.
    Event ID: 40000
    Internal panel hardware fault detected.
    Perform a panel restart. If the fault persists after restart, the panel may require repair or replacement of internal components.
    Event ID: 50000
    Power supply voltage is outside the specified operating range.
    Measure the 24 V DC supply at the panel connector. Ensure the supply voltage is within the 20.4 V to 28.8 V DC range. Check for loose connections or an undersized power supply.
    Event ID: 60000
    Alarm buffer overflow — the number of pending alarms exceeds the panel buffer capacity.
    Acknowledge and clear existing alarms on the panel. Review the alarm configuration in WinCC flexible to ensure alarm limits are set appropriately and nuisance alarms are minimized.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77B (6AV6341-1DC04-0AY0)?

    The OP 77B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP communication interfaces. It can also communicate with S7-200 via PPI protocol.

    What software is required to configure and program the OP 77B?

    The OP 77B is configured using Siemens WinCC flexible 2005 or a later version. Projects are downloaded to the panel via the MPI or PROFIBUS DP interface.

    What is the supply voltage requirement for the 6AV6341-1DC04-0AY0?

    The panel requires a 24 V DC supply voltage, with an acceptable operating range of approximately 20.4 V to 28.8 V DC.

    What is the front panel protection rating of the OP 77B?

    The front face of the OP 77B carries an IP65 protection rating, making it suitable for panel door mounting in environments with dust and water spray exposure.

    Can the OP 77B display graphics or images?

    No, the OP 77B is a text-based operator panel with a 4-line alphanumeric LCD display. It does not support graphical or bitmap image display.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the panel power connector using a multimeter. Verify the supply is within the 20.4 V to 28.8 V DC range. Inspect the connector for loose or reversed wiring.

    Correct any wiring faults and ensure the power supply is correctly rated. If the supply voltage is correct and the display remains blank, the panel backlight or internal power circuitry may be faulty and the unit should be sent for repair.

    Panel displays 'No connection to PLC' or communication error on startup

    Verify the MPI or PROFIBUS DP cable is correctly connected and terminated at both ends. Check that the PLC station address and baud rate in the WinCC flexible project match the physical PLC configuration.

    Correct any address or baud rate mismatches in the WinCC flexible project and re-download. Replace damaged cables and ensure bus termination resistors are installed only at the physical ends of the network segment.

    Project transfer from WinCC flexible fails or does not complete

    Confirm the correct communication interface is selected in WinCC flexible for the download. Check the MPI cable connection between the programming device and the panel. Ensure the panel is in transfer mode.

    Place the panel in transfer mode via the panel's start screen or loader menu. Use a known-good MPI cable and verify the PC adapter settings. Re-attempt the project download after confirming all settings are correct.

    Function keys do not respond when pressed

    Check whether the panel is in the correct operating mode and the project is loaded. Inspect the keypad membrane for physical damage or contamination around the key area.

    Reload the project to ensure key assignments are correctly configured in WinCC flexible. If keys remain unresponsive after project reload, the keypad membrane assembly may be worn or damaged and requires replacement.

    Alarm messages are not displayed on the panel

    Verify that alarm tags are correctly linked to PLC data addresses in the WinCC flexible project. Check that the PLC communication is active and the relevant PLC bits are being set as expected.

    Review the alarm configuration in WinCC flexible and confirm the correct PLC variable addresses are assigned. Re-download the project and test by manually triggering the alarm condition from the PLC.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart