Siemens 6AV6341-1BA33-0AY0 OP 177B
€ 1.995,00
The Siemens 6AV6341-1BA33-0AY0 is an Operator Panel (OP 177B) belonging to the SIMATIC HMI series, designed for machine-level human-machine interface applications. This unit provides a monochrome STN display with touch and key-based operation, enabling operators to monitor and control industrial processes directly at the machine. It is part of Siemens' established SIMATIC HMI panel family, widely deployed across automation environments worldwide.
The OP 177B (6AV6341-1BA33-0AY0) features a 5.7-inch STN monochrome display with a resolution of 320 x 240 pixels (QVGA), supporting both touch screen and membrane keypad input. It is equipped with PROFIBUS DP and MPI interfaces for direct communication with Siemens SIMATIC S7 PLCs, as well as a RS-422/RS-485 serial interface for third-party controller connectivity. The panel runs on WinCC flexible runtime software, offering configurable screens, alarms, trends, and recipes. It operates on a 24 V DC supply and is rated IP65 on the front face for protection against dust and water ingress.
The OP 177B is commonly used in machine building, packaging, food and beverage processing, and general manufacturing automation where a compact, robust operator interface is required at the machine level. Its PROFIBUS DP connectivity makes it particularly suitable for integration into existing Siemens S7-300 and S7-400 PLC architectures. The combination of touch and key operation provides flexibility in environments where gloved operation or harsh conditions may be encountered.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Type | STN monochrome |
| Display Resolution | 320 x 240 pixels (QVGA) |
| Input Method | Touch screen and membrane keypad |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 9 W |
| Communication Interface | PROFIBUS DP, MPI, RS-422/RS-485 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC HMI OP 177B |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between the HMI panel and the connected PLC. The panel cannot establish or maintain a connection to the controller.
Check PROFIBUS/MPI cable connections and termination resistors. Verify the PLC address settings match the HMI project configuration. Ensure the PLC is in RUN mode. - Event ID: 10001
- Connection to PLC interrupted during runtime. The HMI lost communication with the configured controller.
Inspect physical cabling for damage or loose connectors. Check bus termination and cable shielding. Restart both the HMI and PLC if the connection is not restored automatically. - Event ID: 20000
- Project download error. The WinCC flexible project could not be transferred to the panel.
Verify the PC-to-panel connection (USB or Ethernet). Ensure the correct panel type and firmware version are selected in WinCC flexible. Retry the transfer after restarting the panel in transfer mode. - Event ID: 40000
- System memory low. The panel's available runtime memory is insufficient to load all configured project elements.
Reduce the number of active screens, alarms, or data records in the project. Optimize graphics and script usage. Consider archiving historical data to an external memory card. - Event ID: 50000
- Internal device error or hardware fault detected on the panel.
Perform a panel restart. If the error persists, back up the project, perform a factory reset, and reload the project. Contact Siemens support or arrange for hardware inspection if the fault recurs. - Event ID: 60000
- Configuration error detected. The loaded project contains settings incompatible with the current panel firmware or hardware.
Check the WinCC flexible project version against the panel firmware version. Update the firmware if required, or recompile and re-download the project using a compatible version of WinCC flexible. - Event ID: 70000
- Alarm buffer overflow. The number of pending alarms exceeds the panel's alarm buffer capacity.
Acknowledge and clear existing alarms. Review the alarm configuration in WinCC flexible to reduce unnecessary alarm triggers. Increase the alarm buffer size in the project settings if possible.
Frequently Asked Questions
What PLC systems is the OP 177B (6AV6341-1BA33-0AY0) compatible with?
The OP 177B is primarily designed for use with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with third-party controllers via the RS-422/RS-485 serial interface using supported protocols.
What software is used to configure and program the OP 177B?
The OP 177B is configured using Siemens WinCC flexible software. The project is created on a PC and then downloaded to the panel via USB or the communication interface.
What is the supply voltage for the 6AV6341-1BA33-0AY0?
The panel operates on a 24 V DC supply voltage. Ensure the power supply is within the specified tolerance range to guarantee reliable operation.
Does the OP 177B support recipe and alarm management?
Yes, the OP 177B supports recipe management, alarm logging, and trend display as part of its WinCC flexible runtime functionality. These features can be configured in the WinCC flexible project.
What is the front panel protection rating of the OP 177B?
The front face of the OP 177B is rated IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for installation in industrial panel doors.
Troubleshooting
Display remains blank after power on
Check that 24 V DC is present at the power supply terminals. Measure voltage at the panel connector and verify polarity. Inspect the internal fuse if accessible.
Correct any wiring errors or supply voltage issues. If the supply voltage is confirmed correct and the display remains blank, the internal power supply or display backlight may have failed and the unit should be inspected or repaired.
Panel shows 'No connection to PLC' message at runtime
Verify the PROFIBUS DP or MPI cable is securely connected at both the panel and PLC ends. Check bus termination resistors are correctly placed at both ends of the bus segment. Confirm the PLC node address in the HMI project matches the physical PLC address.
Reseat all connectors, correct bus termination, and ensure address settings match. If using PROFIBUS, check the configured baud rate matches the network settings. Restart the panel after corrections.
Touchscreen does not respond or responds inaccurately
Check for physical damage or contamination on the touch surface. Determine whether the issue is limited to specific screen areas or affects the entire display. Attempt a touchscreen recalibration from the panel's system settings menu.
Clean the touch surface with a soft, dry cloth. Perform a touchscreen calibration via the Control Panel in the panel's Start Center. If calibration does not resolve the issue, the touch overlay may require replacement.
Project download fails or panel does not enter transfer mode
Confirm the panel is set to transfer mode either manually via the Start Center or by enabling automatic transfer in the project settings. Check the USB or communication cable for faults. Verify the WinCC flexible version matches the panel firmware.
Restart the panel and manually select 'Transfer' from the Start Center. Replace the communication cable if faulty. Update the panel firmware to match the WinCC flexible project version if a version mismatch is detected.
Panel repeatedly restarts or crashes during operation
Check the 24 V DC supply for voltage dips or instability under load. Review the WinCC flexible project for script errors or memory-intensive configurations. Check for overheating by verifying ambient temperature and ventilation around the panel.
Stabilize the power supply by using a dedicated 24 V DC source with adequate current capacity. Optimize the WinCC flexible project to reduce memory usage. Ensure the installation environment does not exceed the 50 °C maximum operating temperature.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page