Siemens 6AV6341-1BA03-1AY0 OP17
€ 1.995,00
The Siemens 6AV6341-1BA03-1AY0 is an OP17 operator panel belonging to the SIMATIC HMI family of operator panels. It is a compact, text-based operator panel designed for machine-level human-machine interface applications, providing operators with a straightforward means of monitoring and controlling industrial processes. This unit is part of the established OP series, which has been widely deployed across a broad range of automation environments.
The OP17 panel features a multi-line LCD text display capable of showing alphanumeric characters and system messages, with a membrane keypad for operator input. It supports communication via the MPI (Multi-Point Interface) and PROFIBUS-DP protocols, enabling direct integration with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs. The unit operates on a 24 V DC supply and is configured using ProTool software. It offers internal recipe and data storage, alarm management, and supports multiple language configurations for international deployments.
The OP17 is typically used in manufacturing, packaging, and process automation applications where a cost-effective, robust text-based HMI is required at the machine level. Its compact form factor and panel-mount design make it suitable for integration into control cabinets and machine enclosures. Industries such as food and beverage, automotive assembly, and general factory automation commonly deploy this panel for operator guidance, parameter entry, and alarm display tasks.
Technical Specifications
| Display Type | LCD, text-based |
|---|---|
| Display Lines | 4 lines of 20 characters |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 5 W |
| Communication Interface | MPI, PROFIBUS-DP |
| Operating Temperature | 0 °C to 50 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Mounting | Panel mount |
| Configuration Software | ProTool |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between the OP17 and the connected PLC. The panel cannot establish or maintain a connection to the controller.
Check MPI or PROFIBUS-DP cable connections and termination resistors. Verify the PLC address settings match the OP17 configuration. Ensure the PLC is in RUN mode. - Event ID: 10001
- Timeout error on the communication link. The PLC did not respond within the expected time window.
Check network cabling for damage or loose connectors. Verify bus termination at both ends of the network. Reduce bus length or check for electromagnetic interference sources. - Event ID: 10002
- Configuration data mismatch. The project data loaded on the OP17 does not match the connected PLC program.
Re-download the correct ProTool project to the OP17. Ensure the PLC program and HMI project are synchronized and use matching data block addresses. - Event ID: 20000
- Internal memory error detected on the OP17 panel.
Perform a complete reset of the OP17 and reload the project via ProTool. If the error persists, the internal memory or hardware may be faulty and the unit should be repaired or replaced. - Event ID: 30000
- Power supply undervoltage detected. The 24 V DC supply voltage has dropped below the minimum operating threshold.
Measure the 24 V DC supply at the OP17 power connector. Ensure the power supply unit is rated for sufficient current. Check for voltage drops caused by long cable runs or loose terminals. - Event ID: 40000
- Alarm buffer overflow. The number of pending alarms has exceeded the panel's alarm buffer capacity.
Acknowledge and clear existing alarms on the panel. Review the PLC program to identify the root cause of the alarm storm and resolve the underlying process fault. - Event ID: 50000
- Operating system or firmware error detected during startup or operation.
Cycle power to the OP17. If the error recurs, perform a factory reset and reload the firmware and project using ProTool. Contact Siemens technical support if the issue persists.
Frequently Asked Questions
Which PLCs are compatible with the Siemens OP17 (6AV6341-1BA03-1AY0)?
The OP17 is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS-DP communication interfaces. It can also communicate with S5 series PLCs using appropriate adapters and configuration.
What software is used to configure and program the OP17 panel?
The OP17 is configured using Siemens ProTool software. Projects are created on a PC and then downloaded to the panel via the MPI interface or a serial programming cable.
What is the supply voltage for the 6AV6341-1BA03-1AY0?
The OP17 operates on a 24 V DC supply voltage. Ensure the power source is stable and within the specified tolerance range to prevent communication errors or panel resets.
What is the front panel protection rating of the OP17?
The front panel of the OP17 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for installation in industrial control cabinet doors.
Can the OP17 display alarms and process messages?
Yes, the OP17 supports alarm management and can display process messages, operator prompts, and system alarms across its 4-line text display. It includes an alarm buffer for logging events.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the power connector on the rear of the unit. Check for blown internal fuses or damaged power input terminals.
Restore the 24 V DC supply to within specification. If the supply is correct and the display remains blank, the internal power supply board or display module may be faulty and requires repair or replacement.
OP17 shows persistent communication error and cannot connect to PLC
Verify the MPI or PROFIBUS-DP address configured in the ProTool project matches the address set on the PLC. Inspect the communication cable for continuity and correct pin assignment. Check bus termination at both ends of the network.
Correct any address mismatches in the ProTool project and re-download to the panel. Replace damaged cables and ensure proper bus termination resistors are installed at the network endpoints.
Panel keypad buttons are unresponsive or intermittently responsive
Inspect the membrane keypad for physical damage, contamination, or deformation. Check the internal ribbon cable connection between the keypad membrane and the main PCB.
Clean the keypad surface with a dry cloth. If the ribbon cable is loose or damaged, reseat or replace it. If the keypad membrane itself is worn, replace the front panel assembly.
Project download from ProTool fails or is interrupted
Check the serial or MPI programming cable connection between the PC and the OP17. Verify that the correct COM port and transfer settings are selected in ProTool. Ensure the OP17 is in transfer mode.
Replace the programming cable if damaged. Set the OP17 to transfer mode manually via the panel menu before initiating the download. Ensure ProTool is configured with the correct baud rate and interface settings.
Alarm messages appear corrupted or display incorrect characters
Compare the alarm text configuration in the ProTool project with what is displayed on the panel. Check if the correct language and character set are selected in the project settings.
Re-download the ProTool project to the OP17 ensuring the correct language configuration is selected. If character corruption persists, perform a panel reset and reload the project from a verified backup.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page