• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6341-1BA03-0AY0 OP17
    Awaiting product image

    Siemens 6AV6341-1BA03-0AY0 OP17

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6341-1BA03-0AY0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6341-1BA03-0AY0 is an OP17 operator panel belonging to the SIMATIC HMI family of operator panels. It is a compact, text-based operator panel designed for machine-level human-machine interface applications, providing operators with a straightforward means of monitoring and controlling industrial processes. This unit is part of the OP17 series, which was developed for use with Siemens SIMATIC S5 and S7 programmable logic controllers.

    The OP17 panel features a multi-line LCD text display capable of showing alphanumeric characters, enabling the display of process values, alarm messages, and status information. It supports communication via the MPI (Multi-Point Interface) and PROFIBUS-DP protocols, allowing direct integration with SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel includes a membrane keypad with function keys for operator input, and configuration is performed using the ProTool software package. It operates on a 24 V DC supply and is designed for front-panel mounting with an IP65 protection rating on the front face.

    The OP17 is widely used in manufacturing, packaging, and process automation environments where a cost-effective, reliable text-based operator interface is required. It is particularly suited for machine-level control panels in industries such as food and beverage, automotive assembly, and general factory automation. Its compact form factor and robust construction make it appropriate for installation in control cabinets and machine enclosures with limited space.

    Technical Specifications

    Display Type LCD, text-based
    Display Lines 4 lines
    Characters per Line 20 characters
    Input/Operating Voltage 24 V DC
    Power Consumption Approx. 6 W
    Communication Interface MPI, PROFIBUS-DP, RS-232
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to 50 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 10% to 90%, non-condensing
    Mounting Front panel mounting
    Certifications CE, UL
    Series/Product Family SIMATIC HMI OP17

    Common Error Codes & System Events

    System Event 10000
    Communication error between the OP17 and the connected PLC. The panel cannot establish or maintain a connection.
    Check MPI or PROFIBUS-DP cable connections and termination resistors. Verify the PLC address settings and baud rate configuration match those set in ProTool.
    System Event 10001
    PLC not responding or connection to the PLC has been lost during operation.
    Verify PLC is powered and in RUN mode. Check physical cable integrity and connector seating. Confirm network address configuration.
    System Event 10002
    Data record transfer error. A read or write operation to the PLC failed.
    Check PLC program for correct data block addresses referenced in the OP17 project. Ensure the PLC data areas are not write-protected.
    System Event 20000
    Internal device error or configuration file could not be loaded from memory.
    Re-transfer the project configuration from ProTool to the OP17. If the error persists, perform a memory reset and re-download the project.
    System Event 40000
    Alarm buffer overflow. More alarms have been generated than the buffer can store.
    Acknowledge and clear pending alarms. Review the alarm configuration in ProTool to reduce the frequency or number of simultaneous alarms.
    System Event 70010
    Incorrect or incompatible project file detected on the panel.
    Re-download a compatible project file using the correct version of ProTool software. Verify the target device selected in ProTool matches the OP17 hardware.
    System Event 70011
    Panel memory error detected during startup self-test.
    Perform a complete memory reset via the panel's system menu and re-transfer the project. If the fault persists, the internal memory module may require replacement.

    Frequently Asked Questions

    Which PLCs are compatible with the Siemens OP17 (6AV6341-1BA03-0AY0)?

    The OP17 is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS-DP interfaces. It also supports connection to S5 PLCs via RS-232 with appropriate configuration.

    What software is used to configure and program the OP17 panel?

    The OP17 is configured using Siemens ProTool software. Projects are created on a PC and then downloaded to the panel via a serial or MPI connection.

    What is the supply voltage for the 6AV6341-1BA03-0AY0?

    The OP17 operates on a 24 V DC supply voltage, which is standard for SIMATIC HMI operator panels.

    What is the front panel protection rating of the OP17?

    The front face of the OP17 achieves an IP65 protection rating when correctly installed with the supplied sealing gasket, making it suitable for environments with dust and water spray.

    Can the OP17 display graphical content or images?

    No, the OP17 is a text-based operator panel and is limited to displaying alphanumeric characters and special symbols. It does not support graphical or bitmap image display.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the power connector on the rear of the panel. Check for blown internal fuse or wiring polarity errors.

    Correct any wiring faults and ensure the supply voltage is within the 24 V DC tolerance range. If the supply is correct and the display remains blank, the internal power supply or display backlight may be faulty and require repair or unit replacement.

    Panel displays 'No connection to PLC' or communication error on startup

    Check the MPI or PROFIBUS-DP cable between the OP17 and the PLC. Verify bus termination is correctly applied at both ends of the network segment.

    Replace or reseat the communication cable. Confirm the PLC station address and baud rate in the OP17 project match the PLC configuration. Ensure the PLC is powered and in RUN mode.

    Project download from ProTool fails or is interrupted

    Check the serial or MPI cable connection between the programming PC and the OP17. Verify the correct COM port and transfer settings are selected in ProTool.

    Use a known-good transfer cable and confirm the OP17 is in transfer mode via its system menu. Ensure the ProTool project version is compatible with the OP17 firmware version.

    Keypad buttons are unresponsive or intermittently fail

    Inspect the membrane keypad for physical damage, contamination, or wear. Test each key systematically using the panel's built-in key test function in the system menu.

    Clean the keypad surface with a dry cloth. If individual keys are confirmed faulty, the membrane keypad assembly may need to be replaced as a service part.

    Alarm messages are not displayed or are displayed incorrectly

    Review the alarm configuration in the ProTool project to verify that the correct PLC bit addresses are assigned to each alarm. Check that the PLC program is correctly setting the alarm bits.

    Correct any address mismatches in the ProTool project and re-download to the panel. Verify PLC logic is functioning as intended using the PLC programming software online monitoring tools.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart