• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6321-1GC24-0MY6 SIMATIC OP 27
    Awaiting product image

    Siemens 6AV6321-1GC24-0MY6 SIMATIC OP 27

    € 2.495,00

    Reset
    Clear
    SKU: 6AV6321-1GC24-0MY6 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6321-1GC24-0MY6 is an operator panel (OP 27) belonging to the SIMATIC HMI family, designed for human-machine interface applications in industrial automation environments. This unit provides a monochrome or color graphical display interface for process visualization, machine control, and status monitoring. It is part of Siemens' established OP series, which is engineered for robust deployment in demanding industrial settings.

    The OP 27 panel features a 5.7-inch STN display with a resolution of 320 x 240 pixels and supports both text and graphics-based visualization. It is equipped with MPI and PROFIBUS-DP communication interfaces, enabling direct integration with SIMATIC S7-300 and S7-400 PLCs without the need for additional gateways. The unit includes a membrane keypad with function keys for operator input, onboard Flash memory for project storage, and operates on a 24 V DC supply. Configuration is performed using Siemens ProTool or WinCC flexible engineering software.

    The SIMATIC OP 27 is widely used in machine building, process automation, and manufacturing industries where reliable operator interaction with PLC-controlled systems is required. It is commonly found on packaging machinery, conveyor systems, press lines, and general-purpose industrial machines. Its compatibility with the SIMATIC S7 controller family and its compact panel-mount form factor make it a practical choice for retrofit and new installation projects alike.

    Technical Specifications

    Display Size 5.7 inch
    Display Type STN LCD
    Display Resolution 320 x 240 pixels (QVGA)
    Display Colors Monochrome (blue-mode)
    Input/Operating Voltage 24 V DC
    Power Consumption Approx. 10 W
    Communication Interface MPI, PROFIBUS-DP
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP/Protection Rating IP65 (front panel)
    Mounting Panel mounting
    Series/Product Family SIMATIC OP 27
    Engineering Software ProTool, WinCC flexible

    Common Error Codes & System Events

    Event ID: 10000
    No connection to PLC. The HMI panel cannot establish communication with the configured controller.
    Check MPI or PROFIBUS-DP cable connections and termination resistors. Verify PLC address settings match the HMI project configuration. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Communication error with PLC. Data exchange has been interrupted during operation.
    Inspect the communication cable for damage. Verify bus termination and cable shielding. Check for address conflicts on the MPI or PROFIBUS network.
    Event ID: 20000
    Project download failed. The transfer of the HMI project from the engineering PC to the panel was unsuccessful.
    Ensure the panel is in Transfer mode before initiating download. Verify the PC-to-panel cable (PC/MPI adapter or USB-MPI) is correctly connected and the correct COM port is selected in ProTool or WinCC flexible.
    Event ID: 40000
    System memory low. Available memory on the panel is insufficient for the current project or runtime operation.
    Reduce the project size by removing unused screens, tags, or graphics. Perform a full project download after optimization to clear fragmented memory.
    Event ID: 50000
    Illegal system state. The panel has detected an internal runtime error or inconsistent system state.
    Perform a controlled restart of the panel. If the error persists, reload the project via ProTool or WinCC flexible and check for project configuration errors.
    Event ID: 60000
    Backup battery low or missing. The internal buffer battery voltage is below the minimum threshold.
    Replace the internal lithium backup battery with the correct Siemens replacement type. Ensure power is maintained during battery replacement to avoid data loss.
    Event ID: 70000
    Operating system error. A fault has been detected in the panel firmware or operating system.
    Perform a firmware update using the Siemens ProSave tool and the correct firmware version for the OP 27. If the panel fails to boot, a complete OS reload via bootstrap mode may be required.

    Frequently Asked Questions

    Which PLCs are compatible with the SIMATIC OP 27?

    The OP 27 is compatible with SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS-DP interfaces. It can also communicate with S5 controllers using appropriate protocol adapters configured in the engineering software.

    What engineering software is required to configure the OP 27?

    The OP 27 is configured using Siemens ProTool (legacy) or WinCC flexible (Compact or Standard edition). WinCC flexible is the recommended tool for current projects and supports migration from ProTool projects.

    What is the operating voltage for the 6AV6321-1GC24-0MY6?

    The panel operates on 24 V DC, which must be supplied within the specified tolerance range, typically 20.4 V DC to 28.8 V DC.

    Does the OP 27 support touch input?

    No, the OP 27 does not have a touchscreen. Operator input is performed via the integrated membrane keypad, which includes system keys and configurable function keys.

    Can the OP 27 panel be used as a replacement in existing SIMATIC HMI installations?

    Yes, the OP 27 is a direct fit for existing OP 27 installations and is compatible with projects developed for this panel family. Panel cutout dimensions and communication interfaces are standardized within the OP 27 series.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the panel power connector. Check for blown internal fuse. Verify the supply polarity is correct.

    Correct any supply voltage issues or replace the internal fuse if blown. If the supply is confirmed good and the display remains blank, the internal power supply board or backlight inverter may require replacement.

    Panel fails to communicate with the S7 PLC

    Check MPI or PROFIBUS-DP cable continuity and connector integrity. Verify that bus termination resistors are correctly placed at both ends of the network. Confirm that the PLC station address in the HMI project matches the physical PLC configuration.

    Replace damaged cables or connectors. Correct address mismatches in the HMI project and reload the project to the panel. Ensure only the two physical endpoints of the bus have termination resistors enabled.

    Project download from PC to panel fails or times out

    Confirm the panel is set to Transfer mode (accessible via the panel's Start Center or by pressing the appropriate key combination at startup). Verify the PC adapter (USB-MPI or PC/MPI) driver is correctly installed and the correct interface is selected in the engineering software.

    Restart the panel in Transfer mode and retry the download. Update or reinstall the PC adapter drivers if necessary. Try a different USB port or adapter if the issue persists.

    Panel displays 'Battery Low' warning or loses data after power off

    The internal lithium backup battery is discharged or has reached end of life. This battery maintains retentive memory and the real-time clock when panel power is removed.

    Replace the internal backup battery with the correct Siemens-specified lithium cell. Perform the replacement with panel power applied where possible to avoid loss of retentive data, following the procedure in the OP 27 operating instructions.

    Operator keys or function keys do not respond

    Inspect the membrane keypad for physical damage, contamination, or deformation. Check whether the issue is limited to specific keys or affects all keys, which helps distinguish between a keypad hardware fault and a project configuration issue.

    Clean the keypad surface and check for mechanical damage. If individual keys are unresponsive due to membrane wear, the keypad membrane assembly should be replaced. If all keys are unresponsive, verify the project configuration for key assignments and reload the project.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart