• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6321-1DC34-0MY0 SIMATIC OP 321
    Awaiting product image

    Siemens 6AV6321-1DC34-0MY0 SIMATIC OP 321

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6321-1DC34-0MY0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6321-1DC34-0MY0 is an operator panel (OP) belonging to the SIMATIC HMI family, designed for machine-level human-machine interface applications. This unit provides a compact, key-operated interface for process visualization and operator control in industrial automation environments. It is part of Siemens' established SIMATIC HMI portfolio, intended for use with SIMATIC S7 and compatible PLC systems.

    The OP 321 features a monochrome display with a matrix of function keys and system keys, enabling structured navigation and process interaction without touchscreen input. It supports MPI and PROFIBUS DP communication interfaces for direct integration with Siemens SIMATIC S7-300 and S7-400 controllers. The panel is configured using Siemens ProTool or WinCC flexible engineering software, allowing screen layout, alarm management, and recipe handling to be defined offline and downloaded to the device.

    This operator panel is commonly deployed in manufacturing machinery, conveyor systems, packaging equipment, and process automation installations where a robust, key-based interface is preferred over touchscreen operation. Its compact form factor and compatibility with standard SIMATIC controllers make it suitable for retrofit and new-build machine control cabinets across automotive, food and beverage, and general industrial sectors.

    Technical Specifications

    Display Type Monochrome LCD
    Communication Interface MPI, PROFIBUS DP
    Input Voltage 24 V DC
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10 % to 90 %, non-condensing
    IP Protection Rating IP65 (front panel)
    Mounting Panel mounting
    Series/Product Family SIMATIC HMI OP
    Engineering Software ProTool, WinCC flexible
    Certifications CE, UL

    Common Error Codes and System Events

    Event ID: 10000
    Communication error between the OP panel and the connected PLC. The MPI or PROFIBUS DP connection has been interrupted or cannot be established.
    Check MPI/PROFIBUS DP cable connections and terminating resistors. Verify the PLC is powered and the configured station address matches the PLC settings.
    Event ID: 10001
    Configured PLC address not reachable on the bus. The panel cannot find the controller at the specified network address.
    Confirm the PLC station address in the project configuration matches the physical DIP switch or software address setting on the PLC. Check bus cable integrity.
    Event ID: 20000
    Project download error. Transfer of the configuration project from the engineering PC to the OP panel failed.
    Verify the transfer cable connection and that the panel is set to transfer mode. Check that the correct COM port and transfer settings are selected in ProTool or WinCC flexible.
    Event ID: 20001
    Insufficient memory on the OP panel for the downloaded project. The project size exceeds the available flash memory.
    Reduce the project size by removing unused screens, graphics, or recipes. Perform a full memory reset on the panel before re-downloading.
    Event ID: 40000
    Operating system error or firmware mismatch detected. The panel firmware version is incompatible with the downloaded project.
    Update the panel firmware to the version required by the engineering software. Re-download the project after the firmware update is complete.
    Event ID: 50000
    Internal hardware fault detected. A self-test during startup has identified a hardware component failure.
    Perform a power cycle. If the fault persists, back up the project and arrange for hardware inspection or replacement of the operator panel.
    Event ID: 60000
    Screen object configuration error. A display object references a tag or PLC variable that does not exist or is incorrectly configured.
    Open the project in ProTool or WinCC flexible and validate all tag connections. Correct any broken or missing tag references and re-download the project.

    Frequently Asked Questions

    Which communication interfaces does the 6AV6321-1DC34-0MY0 support?

    The panel supports MPI and PROFIBUS DP interfaces, enabling direct connection to Siemens SIMATIC S7-300 and S7-400 PLCs without additional communication modules.

    Which engineering software is used to configure this operator panel?

    The panel is configured using Siemens ProTool or WinCC flexible. Projects are created offline and transferred to the device via a serial transfer cable or MPI connection.

    What is the supply voltage for this OP panel?

    The panel requires a 24 V DC supply voltage, which is standard for SIMATIC HMI devices and typically sourced from the control cabinet power supply.

    What is the IP protection rating of this panel?

    The front face of the panel carries an IP65 protection rating, making it suitable for installation in environments where dust and water spray may be present.

    Is this panel compatible with S7-1200 or S7-1500 PLCs?

    The panel is primarily designed for use with SIMATIC S7-300 and S7-400 controllers via MPI or PROFIBUS DP. Compatibility with S7-1200 or S7-1500 is not supported, as those controllers use PROFINET as their primary interface.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the panel power connector. Check for blown internal fuse or wiring fault at the supply terminals.

    Restore correct 24 V DC supply. If voltage is present and display remains blank, the internal power supply or display backlight may have failed and the unit should be inspected or replaced.

    Panel shows 'No connection to PLC' message continuously

    Check MPI or PROFIBUS DP cable connections at both the panel and PLC ends. Verify bus termination resistors are correctly placed at both ends of the bus segment.

    Replace or reseat the communication cable. Confirm the PLC station address in the panel project matches the actual PLC address. Ensure bus termination is active only at the two physical ends of the network.

    Project download from engineering PC fails or times out

    Verify the panel is in transfer mode (accessible via the panel startup menu). Check the serial or MPI cable connection between the PC and the panel.

    Restart the panel in transfer mode and retry the download. Use the correct transfer cable type and confirm the COM port settings in ProTool or WinCC flexible match the PC hardware.

    Function keys do not respond or produce incorrect actions

    Check the project configuration in the engineering software to confirm key assignments are correctly mapped to the intended functions or PLC tags.

    Re-validate and re-download the project. If keys remain unresponsive after a correct download, the keypad membrane may be worn or damaged and the panel may require hardware repair.

    Panel restarts repeatedly or fails to complete startup

    Observe the startup sequence for any error messages displayed before the restart. Check supply voltage stability and rule out voltage dips during startup.

    Stabilize the 24 V DC supply. If the restart loop continues with a firmware or memory error message, perform a factory reset and re-download the firmware and project. If the fault persists, the unit likely requires hardware service.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart