• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6321-1DC33-1MY0 SIMATIC OP 321
    Awaiting product image

    Siemens 6AV6321-1DC33-1MY0 SIMATIC OP 321

    € 2.495,00

    Reset
    Clear
    SKU: 6AV6321-1DC33-1MY0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6321-1DC33-1MY0 is an operator panel (OP) belonging to the SIMATIC HMI family, designed for machine-level human-machine interface applications. This unit provides a compact, key-operated interface for monitoring and controlling industrial processes, and is part of the SIMATIC OP 300 series of operator panels from Siemens. It is intended for use as a local operator interface in automation systems, enabling operators to interact with PLC-controlled machinery.

    The SIMATIC OP 321 features a monochrome LCD display with a defined resolution suitable for text and simple graphic visualization. It supports communication via MPI (Multi-Point Interface) and PROFIBUS DP, allowing direct integration with Siemens S7-300 and S7-400 PLC families. The panel includes a membrane keypad with function keys for navigation and control, and is configured using Siemens ProTool or WinCC flexible engineering software. The unit operates on a 24 V DC supply and is built to meet industrial environmental requirements.

    This operator panel is widely used in manufacturing, machine building, and process automation environments where a robust, straightforward operator interface is required. It is particularly suited for applications such as packaging machinery, conveyor systems, and general-purpose machine control where text-based or simple graphical displays are sufficient. Its compatibility with the SIMATIC S7 controller family makes it a common choice for system integrators working within the Siemens automation ecosystem.

    Technical Specifications

    Series/Product Family SIMATIC OP 300
    Display Type Monochrome LCD
    Input/Operating Voltage 24 V DC
    Communication Interface MPI, PROFIBUS DP
    Engineering Software ProTool, WinCC flexible
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Protection Rating IP65 (front panel)
    Mounting Panel mounting
    Certifications CE, UL
    Control Type Membrane keypad with function keys

    Common Error Codes & System Events

    Event ID: 1000
    Connection to PLC lost or communication timeout on MPI/PROFIBUS interface.
    Check MPI/PROFIBUS cable connections and termination resistors. Verify PLC is powered and running. Check configured station address matches PLC settings.
    Event ID: 1003
    Project download failed or configuration data corrupted.
    Re-download the project from the engineering PC using ProTool or WinCC flexible. Verify the project is compiled without errors before transfer.
    Event ID: 1004
    Incompatible project version detected on the panel.
    Ensure the engineering software version matches the firmware version on the OP panel. Update firmware or recompile project with a compatible software version.
    Event ID: 1010
    Internal memory error or project data could not be loaded from flash memory.
    Perform a factory reset and re-download the project. If the error persists, the internal flash memory may be faulty and the unit should be repaired or replaced.
    Event ID: 1020
    Tag update error — a configured variable could not be read from the PLC.
    Verify the tag address configured in the project matches the actual PLC data block or memory area. Check PLC program for the corresponding variable.
    Event ID: 1040
    Operator panel startup failed — system software could not be initialized.
    Cycle power to the panel. If the fault persists, perform a firmware update using the appropriate Siemens tool or return the unit for service.
    Event ID: 1050
    Screen saver or backlight timeout active — display appears blank during operation.
    Press any key to reactivate the display. Adjust the screen saver timeout setting in the panel configuration if required.

    Frequently Asked Questions

    Which PLCs are compatible with the 6AV6321-1DC33-1MY0?

    This operator panel is compatible with Siemens SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS DP communication. It can also communicate with S5 PLCs using appropriate protocol settings.

    What engineering software is used to configure this panel?

    The panel is configured using Siemens ProTool or WinCC flexible engineering software. The project is then downloaded to the panel via an MPI or serial connection from the engineering PC.

    What is the supply voltage for this operator panel?

    The 6AV6321-1DC33-1MY0 operates on a 24 V DC supply voltage, which is standard for SIMATIC HMI panels in this series.

    What is the IP protection rating of this panel?

    The front face of the panel is rated IP65, making it suitable for installation in control cabinet doors where protection against dust and water jets is required.

    Can this panel be used as a replacement for older SIMATIC OP panels?

    Yes, the OP 321 is designed as a successor to earlier SIMATIC OP panels and can often be used as a drop-in replacement with appropriate project migration using WinCC flexible.

    Troubleshooting

    Display remains blank after power on

    Measure 24 V DC at the power supply connector. Check internal fuse if accessible. Observe whether any LEDs or backlight activity is present.

    Verify and restore correct 24 V DC supply. Replace the internal fuse if blown. If the power supply is correct but the display remains blank, the backlight or LCD module may be faulty and require replacement.

    Panel displays 'No connection to PLC' message continuously

    Check the MPI or PROFIBUS DP cable between the panel and the PLC. Verify bus termination is correctly applied at both ends of the network. Confirm the PLC station address in the project matches the actual PLC configuration.

    Replace or reseat the communication cable. Correct bus termination using 120-ohm resistors. Update the project configuration to match the correct PLC address and re-download.

    Panel does not respond to keypad input

    Check whether the panel is in screen saver mode. Attempt to press multiple function keys. Observe if the display reacts to any input.

    Press any key to exit screen saver mode. If the keypad is unresponsive, inspect the membrane keypad connector internally for damage or corrosion. Replace the membrane keypad assembly if necessary.

    Project download fails from engineering PC

    Verify the MPI cable connection between the PC adapter and the panel. Check that the correct COM port and transfer speed are selected in the engineering software. Confirm the panel is in transfer mode.

    Place the panel in transfer mode via the start menu. Use the correct PC adapter (e.g., PC Adapter USB) and verify driver installation. Retry the download at a lower baud rate if communication errors occur.

    Panel reboots repeatedly or freezes during operation

    Check the 24 V DC supply for voltage drops or ripple using a multimeter or oscilloscope. Inspect the project for configuration errors such as invalid tag addresses or excessive screen update rates.

    Stabilize the power supply and ensure adequate current capacity. Correct any invalid tag addresses in the project and reduce screen update polling rates. Re-download the corrected project to the panel.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing