Siemens 6AV6321-1CA03-1MY0 OP 321
€ 2.495,00
The Siemens 6AV6321-1CA03-1MY0 is an operator panel (OP 321) belonging to the SIMATIC HMI family, designed for machine-level human-machine interface applications. This unit provides a compact, key-operated interface for process visualization and control, enabling operators to monitor and interact with automated systems. As part of the SIMATIC HMI portfolio, it integrates seamlessly with Siemens PLC platforms and is configured using ProTool or WinCC flexible engineering software.
The OP 321 features a monochrome LCD display with a matrix of function keys, numeric keys, and system keys for direct operator input without a touchscreen. It supports MPI (Multi-Point Interface) and PROFIBUS DP communication protocols for connection to SIMATIC S7 controllers. The panel includes onboard memory for storing project data and recipes, and operates on a 24 V DC supply. Its robust keypad design is suited to environments where touchscreen operation is impractical due to gloves, dust, or vibration.
The OP 321 is typically deployed in manufacturing, process automation, and machine tool environments where a reliable, key-operated HMI is required at the machine front panel. It is well suited for applications in the food and beverage, automotive, and general machinery industries where operators require direct parameter entry and status monitoring. Its compact form factor and panel-mount design allow integration into standard control cabinets and machine enclosures.
Technical Specifications
| Display Type | Monochrome LCD |
|---|---|
| Display Size | 5.5 inch |
| Display Colors | Monochrome (blue/white) |
| Input Voltage | 24 V DC |
| Power Consumption | Approx. 7 W |
| Communication Interface | MPI, PROFIBUS DP |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Mounting | Panel mount |
| Certifications | CE, UL |
| Series/Product Family | SIMATIC HMI OP 321 |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between the HMI panel and the connected PLC controller.
Check MPI/PROFIBUS DP cable connections and termination resistors. Verify PLC address settings match the HMI project configuration. - Event ID: 10001
- Connection to the configured PLC has been lost or interrupted.
Inspect physical communication cables for damage. Confirm PLC is powered and running. Re-establish connection via ProTool or WinCC flexible. - Event ID: 20000
- Project download error — transfer of project data to the panel failed.
Verify the PC-to-panel transfer cable is correctly connected. Check that the panel is in transfer mode and the correct COM port is selected in the engineering tool. - Event ID: 40000
- Internal memory error — project data in panel memory may be corrupted.
Perform a full panel reset and re-download the project from the engineering software. Replace the panel if the error persists after re-download. - Event ID: 50000
- Operating system or firmware version mismatch between the panel and the project file.
Update the panel firmware using ProTool or WinCC flexible to match the version required by the project. Re-download the project after updating. - Event ID: 60000
- Power supply undervoltage detected — supply voltage has dropped below the minimum threshold.
Measure the 24 V DC supply at the panel connector. Ensure the power supply unit is rated for the panel's current draw and check wiring for voltage drop. - Event ID: 70000
- Configuration error — a tag or variable referenced in the project cannot be found in the PLC.
Open the project in ProTool or WinCC flexible and verify all variable addresses match the PLC data block structure. Correct any mismatched addresses and re-download.
Frequently Asked Questions
What communication interfaces does the OP 321 support?
The OP 321 supports MPI and PROFIBUS DP communication protocols, allowing direct connection to SIMATIC S7-300 and S7-400 PLCs.
Which engineering software is used to configure the OP 321?
The OP 321 is configured using Siemens ProTool or WinCC flexible engineering software. Projects are downloaded to the panel via a serial PC-to-panel transfer cable.
What is the supply voltage for the 6AV6321-1CA03-1MY0?
The panel operates on a 24 V DC supply voltage.
Is the OP 321 compatible with SIMATIC S7-1200 or S7-1500 PLCs?
The OP 321 is primarily designed for use with SIMATIC S7-300 and S7-400 controllers via MPI or PROFIBUS DP. Compatibility with S7-1200 and S7-1500 is not supported natively due to protocol and software limitations.
What is the front panel protection rating of the OP 321?
The front panel of the OP 321 carries an IP65 protection rating, making it suitable for installation in environments with dust and water spray.
Troubleshooting
Display remains blank after power on
Measure the 24 V DC supply voltage at the panel's power connector. Check for blown internal fuses or wiring faults in the supply circuit.
Restore the 24 V DC supply to within specification. If the supply is correct and the display remains blank, the internal power supply board or LCD module may require replacement.
Panel displays communication error and cannot connect to PLC
Check the MPI or PROFIBUS DP cable for physical damage, loose connectors, and correct bus termination at both ends. Verify the PLC address configured in the HMI project matches the actual PLC station address.
Replace or reseat the communication cable. Correct the PLC address in the project and re-download. Ensure bus termination resistors are active only at the two physical ends of the network.
Project download fails during transfer from engineering PC
Confirm the panel is set to transfer mode (accessible via the panel's start-up menu). Check that the correct COM port and transfer settings are selected in ProTool or WinCC flexible.
Restart the panel in transfer mode and retry the download. If using a USB-to-serial adapter, verify driver compatibility. Replace the transfer cable if communication cannot be established.
Keys on the operator panel are unresponsive or register incorrect inputs
Inspect the keypad membrane for physical damage, contamination, or deformation. Test individual keys in the panel's built-in key test mode if available.
Clean the keypad surface with a dry cloth. If keys remain unresponsive, the keypad membrane assembly requires replacement. Source a compatible replacement membrane for the OP 321.
Panel repeatedly restarts or enters a boot loop
This may indicate corrupted firmware or project data in the panel memory. Attempt to access the panel's start-up menu during boot to determine if the operating system is intact.
Perform a complete firmware update using the appropriate ProTool or WinCC flexible service pack. If the panel cannot reach the start-up menu, a hardware fault on the CPU board is likely and the unit should be sent for repair or replacement.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page