Siemens 6AV6155-1BD00-1LS0 SIMATIC Panel PC 670
€ 1.995,00
The Siemens 6AV6155-1BD00-1LS0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface applications, combining computing power with a robust touch-enabled display in a single integrated unit. This product is part of Siemens' SIMATIC HMI portfolio, intended for use as an operator station in industrial automation environments.
The SIMATIC Panel PC 670 features a 15-inch TFT color display with a resolution of 1024 x 768 pixels (XGA), supporting touch screen operation for intuitive operator interaction. It is built around an industrial-grade processor platform and runs Microsoft Windows operating systems, enabling compatibility with SIMATIC WinCC and other SCADA or visualization software. The unit provides multiple communication interfaces including Ethernet (RJ45) and serial ports, and supports expansion via standard PC interfaces such as USB and PCI slots. It is designed for panel mounting with an IP65 protection rating on the front face, ensuring resistance to dust and water ingress in industrial settings.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine building applications where a full PC-based HMI solution is required. It is suitable for industries such as automotive, food and beverage, chemical processing, and discrete manufacturing. Its ability to run standard Windows-based software alongside SIMATIC visualization tools makes it a flexible platform for complex operator interface and data acquisition tasks.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Resolution | 1024 x 768 pixels (XGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touch screen |
| Input/Operating Voltage | 24 V DC |
| IP/Protection Rating | IP65 (front), IP20 (rear) |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | Ethernet (RJ45), RS-232, USB |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
| Operating System | Microsoft Windows XP / Windows 2000 |
Common Error Codes and System Events
- Event ID: 1001
- Application error in WinCC Runtime — the visualization software has encountered an unexpected exception and terminated.
Restart WinCC Runtime. Check the Windows Event Viewer for detailed error logs. Reinstall WinCC Runtime if the issue persists. - Event ID: 1003
- System crash or unexpected shutdown detected — Windows recorded an unclean shutdown on the previous boot cycle.
Check hardware for overheating or power supply instability. Run Windows memory diagnostics and check hard disk integrity using chkdsk. - Event ID: 7026
- Boot-start or system-start driver failed to load — a required hardware driver did not initialize correctly during startup.
Check Device Manager for driver errors. Reinstall the relevant hardware driver or restore from a known-good system image. - Event ID: 6008
- Unexpected shutdown — the system was shut down unexpectedly, possibly due to power loss or hardware fault.
Verify the 24 V DC supply voltage stability. Check UPS or power conditioning equipment. Inspect internal connections and power supply module. - Communication Error
- Loss of communication between the Panel PC and the connected PLC or automation controller.
Check Ethernet or serial cable connections. Verify IP address configuration and network settings. Confirm PLC is powered and running. - Hard Disk Error
- SMART diagnostic or Windows disk error indicating potential failure of the internal hard disk drive.
Back up all data immediately. Replace the internal HDD with a compatible industrial-grade drive and restore the system image. - Watchdog Timeout
- The hardware watchdog timer has triggered a system reset due to the operating system or application becoming unresponsive.
Investigate CPU load and running processes. Ensure WinCC and background applications are not consuming excessive resources. Check for software conflicts.
Frequently Asked Questions
What operating systems are supported by the SIMATIC Panel PC 670 (6AV6155-1BD00-1LS0)?
The SIMATIC Panel PC 670 supports Microsoft Windows 2000 and Windows XP. It is compatible with SIMATIC WinCC and other Windows-based SCADA and visualization software.
What is the display size and resolution of this Panel PC?
The unit features a 15-inch TFT color display with a resolution of 1024 x 768 pixels (XGA) and resistive touch screen input.
What is the supply voltage for the 6AV6155-1BD00-1LS0?
The Panel PC 670 operates on a 24 V DC supply voltage, which is standard for SIMATIC industrial HMI devices.
What is the front panel protection rating of this unit?
The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it resistant to dust and low-pressure water jets, suitable for industrial panel installation.
Is the internal hard disk replaceable on this Panel PC?
Yes, the internal hard disk drive is a standard industrial component that can be replaced. It is recommended to maintain a system image backup to facilitate rapid restoration after a drive replacement.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power input connector. Verify the power LED status. Measure voltage at the internal power supply output rails.
Ensure the 24 V DC supply is within tolerance. Replace the internal power supply if output voltages are absent. Check and reseat internal display cable connections.
Touch screen does not respond or is inaccurate
Determine whether the issue is a complete lack of response or positional inaccuracy. Check if the touch controller is recognized in Windows Device Manager.
Recalibrate the touch screen using the Windows touch calibration utility. If unresponsive, reinstall the touch screen driver. Replace the touch screen overlay if calibration does not resolve the issue.
System fails to boot or continuously restarts
Observe the boot sequence for error messages. Check Windows Event Viewer logs if the system reaches the OS. Test the hard disk using diagnostic tools.
Replace the internal hard disk if SMART errors are detected and restore from a system image. If the issue is RAM-related, reseat or replace the memory modules. Verify BIOS settings are correct.
WinCC Runtime fails to start or crashes on startup
Check Windows Event Viewer for application error codes. Verify that the WinCC license dongle is present and recognized. Confirm that all required WinCC components are installed.
Reinstall WinCC Runtime software. Ensure the hardware license key (dongle) is correctly inserted and recognized. Check for Windows OS corruption and repair using the installation media if necessary.
Loss of communication with PLC after network configuration change
Ping the PLC IP address from the Panel PC to verify network connectivity. Check the WinCC communication channel configuration for correct IP address and protocol settings.
Update the WinCC communication channel settings to match the new network configuration. Verify subnet mask and gateway settings. Ensure no IP address conflicts exist on the network.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page