• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6146-4PP41-3KY3 SIMATIC MP 377
    Awaiting product image

    Siemens 6AV6146-4PP41-3KY3 SIMATIC MP 377

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6146-4PP41-3KY3 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6146-4PP41-3KY3 is a Multi Panel belonging to the SIMATIC MP 377 series, part of Siemens' SIMATIC HMI product family. This high-performance operator panel is designed for demanding industrial visualization and control tasks, offering a large-format display and robust construction suitable for harsh industrial environments. It serves as a powerful human-machine interface platform capable of running WinCC flexible runtime software for complex process visualization.

    The MP 377 panel features a 15-inch TFT display with a resolution of 1024 x 768 pixels and 64,000 colors, providing clear and detailed process visualization. It is equipped with a resistive touch screen as well as function keys for flexible operator input. The unit supports multiple communication interfaces including PROFIBUS DP, PROFINET (Ethernet), MPI, and USB ports, enabling seamless integration into a wide range of automation architectures. It runs on Microsoft Windows CE and provides substantial user memory for project data, scripts, and recipes, along with a CompactFlash card slot for additional storage expansion.

    The SIMATIC MP 377 is widely deployed in industries such as automotive manufacturing, food and beverage processing, chemical plants, water treatment facilities, and machine building. Its large display area and multi-protocol communication capabilities make it particularly suitable for complex SCADA-level visualization tasks at the machine or cell level. The panel is compatible with Siemens S7-300, S7-400, and S7-1500 PLC families, as well as third-party controllers via standard communication protocols.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 pixels (XGA)
    Display Colors 64,000 colors
    Display Type TFT LCD
    Touch Technology Resistive touch screen
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 60 W
    Communication Interface PROFIBUS DP, MPI, PROFINET (Ethernet RJ45), 2x USB
    Operating System Windows CE 6.0
    User Memory 12 MB (project memory)
    Storage Expansion CompactFlash card slot
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90%, non-condensing
    IP Rating (Front) IP65
    Mounting Panel mounting
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between HMI panel and PLC controller. Connection to the configured PLC could not be established or was interrupted.
    Check physical communication cable connections (PROFIBUS or Ethernet). Verify PLC address settings and communication parameters in the HMI project configuration. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Tag read error. The HMI panel cannot read the value of a configured tag from the PLC.
    Verify the tag address configured in WinCC flexible matches the actual PLC data block or memory address. Check PLC program to ensure the address exists and is accessible.
    Event ID: 10002
    Tag write error. The HMI panel cannot write a value to the configured PLC tag.
    Check that the target PLC address is not write-protected. Verify the data type of the tag matches the PLC variable. Confirm communication link is active.
    Event ID: 20000
    Project transfer error. A project download to the panel was interrupted or failed.
    Check the transfer cable or network connection between the engineering PC and the panel. Ensure WinCC flexible is set to the correct transfer mode and the panel is in transfer mode. Retry the download.
    Event ID: 40000
    System memory low. Available runtime memory on the panel is critically low, which may cause instability.
    Reduce the complexity of the HMI project, minimize the number of active screens and scripts, and remove unused resources. Consider using a CompactFlash card for additional storage.
    Event ID: 50000
    Recipe data error. An error occurred during reading or writing of recipe data.
    Check recipe configuration in WinCC flexible. Verify that the CompactFlash card is properly inserted and has sufficient free space. Re-export and re-import recipe data if necessary.
    Event ID: 70000
    Screen object error. A configured screen object could not be rendered or updated correctly.
    Check the configuration of the affected screen object in WinCC flexible. Verify all linked tags and dynamic properties are correctly defined. Recompile and retransfer the project.

    Frequently Asked Questions

    What PLC families are compatible with the SIMATIC MP 377?

    The MP 377 is compatible with Siemens S7-300, S7-400, S7-1500, and S7-200 PLC families via MPI, PROFIBUS DP, or PROFINET interfaces. It also supports third-party controllers through OPC or standard Ethernet protocols.

    What software is used to program and configure the MP 377?

    The MP 377 is configured using Siemens WinCC flexible 2008 engineering software. Projects are compiled and transferred to the panel via Ethernet, USB, or MPI/PROFIBUS connection.

    Does the MP 377 support both touch and key input?

    Yes, the MP 377 features a resistive touch screen combined with physical function keys, allowing flexible operator interaction suited to environments where gloved operation may be required.

    What is the supply voltage for the 6AV6146-4PP41-3KY3?

    The panel operates on 24 V DC supply voltage, which is standard for SIMATIC HMI panels and compatible with typical industrial control cabinet power supplies.

    Can the MP 377 be used with WinCC Runtime Advanced or TIA Portal?

    The MP 377 is designed for use with WinCC flexible 2008 and is not natively supported in TIA Portal. For TIA Portal-based projects, Siemens Comfort Panels or newer HMI generations are recommended.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the panel power connector. Verify the supply is within the specified range and the connector is firmly seated. Inspect for any blown internal fuses.

    Restore correct 24 V DC supply voltage. If the supply is correct but the display remains blank, the internal power supply board or backlight inverter may be faulty and require replacement or professional repair.

    Touch screen does not respond or responds inaccurately

    Attempt to recalibrate the touch screen through the panel's Start Center or Control Panel settings. Check for physical damage, contamination, or scratches on the touch surface.

    Perform a touch screen recalibration via the Windows CE Control Panel. Clean the screen surface with a soft, dry cloth. If calibration fails repeatedly, the touch screen overlay may need to be replaced.

    Panel fails to establish communication with the PLC

    Verify the communication cable type and wiring between the panel and PLC. Check that the PLC address, subnet, and protocol settings in the HMI project match the actual PLC configuration.

    Correct any mismatched communication parameters in WinCC flexible and retransfer the project. Replace the communication cable if damaged. Confirm the PLC is powered on and in RUN mode.

    Project transfer from engineering PC fails

    Ensure the panel is set to Transfer mode via the Start Center. Check the network or USB connection between the PC and panel. Verify that the WinCC flexible version matches the project version.

    Switch the panel to Transfer mode manually. Use a known-good USB or Ethernet cable. Ensure firewall settings on the engineering PC do not block the transfer. Retry the download from WinCC flexible.

    Panel reboots unexpectedly or freezes during operation

    Check the 24 V DC supply for voltage dips or instability. Review the HMI project for excessive script complexity or memory usage. Inspect the CompactFlash card for errors.

    Stabilize the power supply using a UPS or higher-rated power supply unit. Optimize the HMI project to reduce memory load. Replace the CompactFlash card if it is found to be faulty or corrupted.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart