• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6146-4MM41-0KY2 SIMATIC MP 377
    Awaiting product image

    Siemens 6AV6146-4MM41-0KY2 SIMATIC MP 377

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6146-4MM41-0KY2 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6146-4MM41-0KY2 is a Multi Panel belonging to the SIMATIC MP 377 series, part of Siemens' SIMATIC HMI product family. This high-performance operator panel is designed for demanding visualization and control tasks in industrial automation environments. It features a 15-inch widescreen TFT display and runs on the Windows CE 6.0 operating system, providing a robust and flexible platform for machine-level HMI applications.

    The MP 377 15" Touch is equipped with a resistive touchscreen and delivers a display resolution of 1024 x 768 pixels with 64,000 colors. It features a 1 GHz processor with 128 MB RAM and 128 MB flash memory for user projects and data storage. Communication interfaces include PROFIBUS DP, PROFINET (Ethernet), USB, and a serial RS-422/RS-485 interface, enabling integration with a wide range of Siemens and third-party controllers. The panel supports WinCC flexible runtime software and is compatible with SIMATIC S7, S5, and various third-party PLC systems.

    The SIMATIC MP 377 is widely deployed in machine building, automotive manufacturing, food and beverage processing, and chemical industry applications. Its large display area and multi-touch capability make it suitable for complex process visualization, recipe management, and alarm handling on production lines. The panel's robust industrial design and wide operating temperature range ensure reliable operation in harsh factory floor environments.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 pixels (XGA)
    Display Colors 64,000 colors
    Display Type TFT LCD
    Touch Technology Resistive touchscreen
    Processor 1 GHz
    RAM 128 MB
    Flash Memory 128 MB
    Operating System Windows CE 6.0
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 60 W
    Communication Interface PROFIBUS DP, PROFINET (Ethernet RJ45), USB 2.0, RS-422/RS-485
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    IP Rating (Front) IP65
    Certifications CE, UL, cULus
    Mounting Panel mounting
    Series/Product Family SIMATIC MP 377

    Common Error Codes & System Events

    Event ID: 1000000
    System startup completed. The HMI device has booted and the runtime software has started successfully.
    No action required. Informational event confirming normal startup.
    Event ID: 1000002
    Connection to PLC lost. The HMI panel cannot establish or has lost communication with the configured PLC.
    Check PROFIBUS or PROFINET cabling and connectors. Verify PLC is powered and running. Confirm network address and communication settings in WinCC flexible project.
    Event ID: 1000003
    Connection to PLC established. Communication between the HMI panel and the PLC has been successfully restored.
    No action required. Informational event confirming restored communication.
    Event ID: 1000005
    Tag read/write error. A configured tag could not be read from or written to the PLC.
    Verify the tag address in the WinCC flexible project matches the actual PLC data block or memory area. Check PLC program for address conflicts.
    Event ID: 1000010
    Project transfer active. A project download from the engineering PC to the HMI device is in progress.
    No action required during intentional transfer. If unexpected, check network security and ensure no unauthorized access to the panel.
    Event ID: 1000070
    Illegal system activity. An operation was attempted that is not permitted in the current operating mode.
    Review user authorization levels in the WinCC flexible project. Ensure the correct user group permissions are assigned for the attempted operation.
    Event ID: 1000071
    Data record transfer error. A recipe data record could not be transferred between the HMI and the PLC.
    Check recipe configuration in WinCC flexible. Verify PLC data block size matches the recipe structure. Ensure sufficient memory is available on the HMI device.
    Event ID: 1000080
    Internal device error. A hardware or firmware fault has been detected within the HMI panel.
    Perform a warm restart of the panel. If the error persists, back up the project, perform a factory reset, and reload the project. Contact Siemens technical support if the fault recurs.

    Frequently Asked Questions

    What PLC systems are compatible with the SIMATIC MP 377?

    The MP 377 is compatible with Siemens SIMATIC S7-300, S7-400, S7-1200, S7-1500, and S5 series PLCs via PROFIBUS DP or PROFINET. It also supports communication with third-party controllers through OPC and serial protocols.

    What software is required to program and configure the MP 377?

    The MP 377 is configured using Siemens WinCC flexible 2008 or later. Projects can also be migrated and used with TIA Portal WinCC in some configurations.

    What is the supply voltage for the 6AV6146-4MM41-0KY2?

    The panel operates on 24 V DC with a maximum power consumption of approximately 60 W.

    What is the IP protection rating of the MP 377 front panel?

    The front panel of the MP 377 achieves IP65 protection, making it resistant to dust ingress and low-pressure water jets when correctly installed in a panel cutout.

    Does the MP 377 support data logging and recipe management?

    Yes, the MP 377 supports data logging, trend displays, alarm logging, and recipe management through the WinCC flexible runtime environment, with data storable on internal flash memory or external USB media.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the panel's power connector. Check that the supply is within the specified tolerance. Inspect the internal fuse if accessible.

    Ensure the 24 V DC supply is stable and within tolerance. If the supply is correct and the display remains blank, the internal power supply board or backlight inverter may have failed and the unit should be sent for repair or replacement.

    Touchscreen does not respond or responds inaccurately

    Attempt to operate the panel using an external USB mouse to determine if the issue is isolated to the touchscreen. Check for physical damage or contamination on the touch surface.

    Perform a touchscreen recalibration through the Windows CE Control Panel or the Siemens Start Center. Clean the touch surface with a soft, dry cloth. If calibration does not resolve the issue, the resistive touch overlay may require replacement.

    HMI cannot communicate with the PLC over PROFINET

    Verify the Ethernet cable connection and check the link LEDs on the RJ45 port. Ping the PLC IP address from the HMI network settings. Confirm that the IP address, subnet mask, and device name configured in the project match the actual network settings.

    Correct any IP address or device name mismatches in the WinCC flexible project and reload the project to the panel. Replace the Ethernet cable if no link is detected. Check switch or network infrastructure for faults.

    Panel repeatedly restarts or crashes during runtime

    Check the operating temperature around the panel and ensure ventilation clearances are maintained. Review the system event log in WinCC flexible for recurring event IDs. Check available flash memory on the device.

    Reduce ambient temperature if overheating is suspected. Delete unnecessary data logs or archived files to free flash memory. If crashes persist, perform a firmware update or factory reset and reload the project.

    Project transfer from engineering PC fails

    Verify the network connection between the PC and the HMI panel. Ensure the panel is in Transfer mode via the Start Center. Check that the WinCC flexible version on the PC is compatible with the panel firmware version.

    Switch the panel to Transfer mode manually through the Start Center. Confirm firewall settings on the engineering PC are not blocking the transfer. Update panel firmware if a version mismatch is identified.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart