• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6146-3PP41-1KY3 SIMATIC MP 377
    Awaiting product image

    Siemens 6AV6146-3PP41-1KY3 SIMATIC MP 377

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6146-3PP41-1KY3 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6146-3PP41-1KY3 is a Multi Panel belonging to the SIMATIC MP 377 series, part of Siemens' SIMATIC HMI product line. This panel is a high-performance operator interface device designed for demanding industrial visualization and control tasks. It features a 15-inch widescreen TFT display and runs on the Windows CE operating system, making it suitable for complex HMI applications.

    The MP 377 15" Touch features a resistive touchscreen interface with a display resolution of 1024 x 768 pixels (XGA) and 64,000 colors. It is equipped with 12 MB user memory for application data and supports a wide range of communication interfaces including PROFIBUS DP, PROFINET IO (via Ethernet), MPI, and USB ports. The panel supports the SIMATIC WinCC flexible runtime environment and offers robust connectivity options including two RS-422/RS-485 ports and two USB 2.0 ports. An integrated CompactFlash card slot provides additional storage expansion capability.

    The SIMATIC MP 377 is widely deployed in manufacturing automation, process control, and machine building applications across industries such as automotive, food and beverage, chemical processing, and packaging. Its large display area and multi-protocol communication support make it well suited for supervisory control panels, production line monitoring stations, and complex machine operator interfaces where high data density visualization is required.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 pixels (XGA)
    Display Colors 64,000 colors
    Touch Technology Resistive touchscreen
    Operating System Windows CE 5.0
    User Memory 12 MB
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 40 W
    Communication Interface PROFIBUS DP, MPI, PROFINET IO (Ethernet), RS-422/RS-485, USB 2.0
    Storage Expansion CompactFlash card slot
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90%, non-condensing
    IP Rating (Front) IP65
    Mounting Panel mounting
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 040000
    Configuration error detected during startup; the project file may be corrupt or incompatible with the panel firmware version.
    Reload the WinCC flexible project to the panel using a compatible firmware version. Verify project compatibility settings in WinCC flexible engineering software.
    Event ID: 070000
    Communication connection to the configured PLC or controller has been lost or cannot be established.
    Check PROFIBUS/MPI/Ethernet cabling and connector integrity. Verify PLC address settings and communication parameters in the WinCC flexible project match the controller configuration.
    Event ID: 080000
    Tag read/write error; the HMI panel cannot access a configured tag on the connected controller.
    Verify the tag address in the WinCC flexible project is correct and that the corresponding data block or memory area exists in the PLC program.
    Event ID: 110000
    Overflow of the alarm buffer; the number of pending alarms exceeds the configured alarm buffer capacity.
    Acknowledge and clear active alarms on the panel. Increase the alarm buffer size in the WinCC flexible project configuration if recurring.
    Event ID: 140000
    Recipe data error; a recipe record could not be read from or written to the configured storage location.
    Check the recipe storage path and ensure the CompactFlash card or internal memory is not full or corrupted. Re-transfer recipe data from the engineering station.
    Event ID: 160000
    System memory low warning; available runtime memory on the panel is critically low.
    Reduce the number of simultaneously active screens or objects. Optimize the WinCC flexible project to reduce memory usage and restart the panel runtime.
    Event ID: 180000
    Firmware update error; a firmware update process was interrupted or failed to complete successfully.
    Restart the panel and reattempt the firmware update using the correct firmware package for the MP 377 15" Touch via ProSave or WinCC flexible.

    Frequently Asked Questions

    What HMI software is required to program the SIMATIC MP 377?

    The MP 377 is programmed using Siemens SIMATIC WinCC flexible 2008 or later. Projects are transferred to the panel via Ethernet, USB, or MPI/PROFIBUS connection using the ProSave tool or directly from WinCC flexible.

    Which communication protocols does the 6AV6146-3PP41-1KY3 support?

    This panel supports MPI, PROFIBUS DP, PROFINET IO via Ethernet (10/100 Mbit/s), and serial RS-422/RS-485 interfaces, allowing connection to a wide range of Siemens S7 PLCs and third-party controllers.

    Is the MP 377 compatible with SIMATIC S7-300 and S7-400 PLCs?

    Yes, the MP 377 is fully compatible with SIMATIC S7-300 and S7-400 PLCs via MPI, PROFIBUS DP, or PROFINET IO. It can also communicate with S7-1200 and S7-1500 controllers via Ethernet using appropriate driver configurations.

    What is the supply voltage for the 6AV6146-3PP41-1KY3?

    The panel operates on 24 V DC with a maximum power consumption of approximately 40 W. The supply must be a regulated SELV/PELV power source.

    Can the MP 377 display be replaced or repaired if damaged?

    The TFT display assembly and touchscreen digitizer can be replaced as spare parts by qualified technicians. Siemens and authorized repair centers offer display replacement services for the MP 377 series.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the panel power connector. Check for blown internal fuse. Verify the power supply can deliver sufficient current (minimum 2 A at 24 V DC).

    Replace the power supply if voltage is absent or out of tolerance. If supply voltage is correct, the internal power board or backlight inverter may be faulty and require replacement by a qualified repair technician.

    Touchscreen does not respond or responds inaccurately to touch input

    Check whether the touch input is disabled in the panel's Control Panel settings. Attempt a touchscreen recalibration via the Windows CE Control Panel. Inspect the touchscreen surface for damage or contamination.

    Perform a touchscreen calibration from the Windows CE Control Panel under 'Touch' settings. If calibration does not resolve the issue, the resistive touchscreen digitizer layer may be worn or damaged and requires replacement.

    Panel fails to establish communication with the PLC

    Verify the communication cable type and wiring for the selected interface (MPI, PROFIBUS, or Ethernet). Check the PLC address and baud rate settings in the WinCC flexible project match the physical PLC configuration. Use a bus diagnostic tool to check for PROFIBUS termination issues.

    Correct any address or baud rate mismatches in the WinCC flexible project and retransfer to the panel. Ensure PROFIBUS bus termination resistors are correctly placed at both ends of the network. Replace faulty cables or connectors as needed.

    Panel restarts unexpectedly or enters a reboot loop

    Check the 24 V DC supply for voltage dips or instability under load. Review the system event log in WinCC flexible for recurring event IDs. Inspect the CompactFlash card for corruption.

    Stabilize the power supply and ensure adequate current capacity. Reformat or replace the CompactFlash card and reload the firmware and project. If the issue persists, the internal CPU board may require inspection or replacement.

    WinCC flexible project transfer fails or times out

    Verify the transfer channel settings in WinCC flexible match the physical connection (USB, Ethernet, or MPI). Ensure the panel is in 'Transfer' mode, accessible via the panel's Start Center or by pressing the transfer button during startup.

    Switch the panel to Transfer mode manually via the Start Center. Confirm firewall settings on the engineering PC do not block the transfer port. Try an alternative transfer medium (e.g., switch from Ethernet to USB) to isolate the issue.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart