• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6146-1LP00-1KC1 MP 377
    Awaiting product image

    Siemens 6AV6146-1LP00-1KC1 MP 377

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6146-1LP00-1KC1 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6146-1LP00-1KC1 is a Multi Panel (MP 377) belonging to the SIMATIC HMI family, designed for high-performance human-machine interface applications. This unit features a 15-inch TFT display and operates as a standalone operator panel running the WinCC flexible runtime environment. It is part of Siemens' SIMATIC HMI MP 377 series, which is engineered for demanding industrial visualization and control tasks.

    The MP 377 (6AV6146-1LP00-1KC1) is equipped with a resistive touchscreen and an integrated keypad for flexible operator input. It supports multiple communication interfaces including PROFIBUS DP, MPI, and Ethernet (PROFINET), enabling seamless integration into a wide range of automation architectures. The panel runs on a Windows CE operating system and provides substantial onboard memory for project data, recipes, and data logs. It supports USB ports for peripheral connectivity and a CompactFlash card slot for extended storage.

    The MP 377 15-inch touch panel is widely deployed in industries such as automotive manufacturing, food and beverage processing, chemical plants, and machine building. Its large display area and multi-protocol communication capability make it suitable for complex process visualization, recipe management, and alarm handling on large-scale machinery and production lines. The panel's robust construction and wide operating temperature range allow reliable operation in harsh industrial environments.

    Technical Specifications

    Display Size 15 inch
    Display Type TFT LCD
    Display Resolution 1024 x 768 px (XGA)
    Display Colors 64,000 colors
    Touch Technology Resistive touchscreen
    Input/Operating Voltage 24 V DC
    Power Consumption Approx. 30 W
    Communication Interface PROFIBUS DP, MPI, Ethernet (PROFINET), USB
    Operating System Windows CE 6.0
    Memory (RAM) 128 MB
    Memory (Flash) 256 MB
    Storage Expansion CompactFlash card slot
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    Mounting Panel mounting
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC or controller. The configured connection cannot be established.
    Check the communication cable and connector integrity. Verify the PLC address settings and communication parameters in the WinCC flexible project. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Connection to the PLC was interrupted during runtime after a previously successful connection.
    Check network or PROFIBUS cabling for loose connections. Verify PLC is still in RUN mode. Restart the HMI runtime and check for electromagnetic interference on the communication line.
    Event ID: 20000
    Tag read error — the HMI is unable to read a configured tag from the PLC.
    Verify the tag address in the WinCC flexible project matches the actual PLC data block or memory area. Check that the PLC program has not been modified to remove or relocate the referenced address.
    Event ID: 20001
    Tag write error — the HMI is unable to write a value to the configured PLC tag.
    Check that the target PLC memory area is not write-protected. Verify the tag address configuration in the WinCC flexible project and confirm the PLC is in a state that accepts write commands.
    Event ID: 40000
    Recipe data error — a recipe record could not be read from or written to the configured storage location.
    Check the storage medium (CompactFlash card or internal flash) for available space and integrity. Re-transfer the project to the panel and verify recipe configuration settings in WinCC flexible.
    Event ID: 70000
    System error — the HMI runtime has encountered an internal software fault or the project file is corrupted.
    Perform a controlled restart of the panel. If the error persists, re-transfer the WinCC flexible project to the panel using a PC with ProSave or WinCC flexible software. Check for firmware compatibility.
    Event ID: 50000
    Alarm logging error — the HMI cannot write alarm entries to the configured data log or storage medium.
    Check available storage space on the CompactFlash card or internal memory. Verify alarm log configuration in the WinCC flexible project and ensure the storage path is correctly defined.

    Frequently Asked Questions

    What display size does the 6AV6146-1LP00-1KC1 have?

    The 6AV6146-1LP00-1KC1 features a 15-inch TFT LCD display with a resolution of 1024 x 768 pixels (XGA) and 64,000 colors.

    What communication protocols does the MP 377 support?

    The MP 377 supports PROFIBUS DP, MPI, and Ethernet (PROFINET) for PLC communication, as well as USB ports for peripheral devices such as keyboards, mice, and USB storage.

    Which Siemens PLCs is the MP 377 compatible with?

    The MP 377 is compatible with SIMATIC S7-300, S7-400, S7-1200, and S7-1500 PLCs, as well as other controllers supported by WinCC flexible, including third-party controllers via appropriate drivers.

    What software is required to program or configure this HMI panel?

    The MP 377 is configured using Siemens WinCC flexible 2008 or later. Projects are transferred to the panel via Ethernet, USB, or MPI/PROFIBUS connection using ProSave or directly from WinCC flexible.

    What is the front panel protection rating of the 6AV6146-1LP00-1KC1?

    The front panel of the MP 377 is rated IP65, making it suitable for installation in environments where protection against dust and water jets is required.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the power connector. Check that the voltage is within the specified tolerance. Inspect the internal fuse if accessible.

    Ensure the 24 V DC supply is stable and within specification. If the supply is correct and the display remains blank, the internal power supply board or backlight inverter may be faulty and the unit should be sent for repair or the backlight replaced.

    Touchscreen does not respond or responds inaccurately

    Attempt to operate the panel using the physical keypad if available. Check whether the touch issue is localized to a specific area of the screen or affects the entire surface.

    Perform a touchscreen recalibration through the panel's Control Panel settings in Windows CE. If recalibration does not resolve the issue, the resistive touch overlay may be damaged and requires replacement.

    HMI cannot establish communication with the PLC

    Verify the communication cable type and wiring. Check the IP address, subnet mask, and PROFIBUS node address settings on both the HMI and the PLC. Use a network diagnostic tool to confirm connectivity.

    Correct any mismatched communication parameters in the WinCC flexible project and re-transfer the project to the panel. Replace the communication cable if continuity testing reveals a fault.

    Panel repeatedly restarts or crashes during runtime

    Check the operating temperature of the installation environment. Review the system event log accessible via the panel's Start menu for recurring Event IDs. Verify the project file integrity.

    Ensure adequate ventilation around the panel to prevent overheating. Re-transfer the WinCC flexible project to the panel. If instability continues, perform a firmware update using ProSave and the latest firmware package from Siemens support.

    CompactFlash card not recognized by the panel

    Remove and reinsert the CompactFlash card. Check the card in another device to confirm it is functional. Inspect the card slot on the panel for bent pins or debris.

    Format the CompactFlash card using the panel's built-in formatting tool in Windows CE Control Panel. If the card is recognized in another device but not the panel, the CompactFlash slot on the panel may require repair or replacement.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart