
Siemens 6AV5583-1AB20-0AB0 SIMATIC OP 5
€ 507,00
The Siemens 6AV5583-1AB20-0AB0 is an Operator Panel (OP) belonging to the SIMATIC OP 5 series, manufactured by Siemens as part of their classic HMI product line. This unit is a compact, text-based operator panel designed for machine-level human-machine interface applications, providing operators with a straightforward means of monitoring and controlling industrial processes. It is a predecessor-generation panel intended for use with Siemens SIMATIC S5 and early S7 PLC families.
The SIMATIC OP 5 features a small LCD text display capable of showing alphanumeric characters and system messages, with a membrane keypad for operator input. It communicates via the MPI (Multi-Point Interface) or TTY/20mA current loop interfaces, enabling direct connection to SIMATIC S5 and S7 controllers. The panel operates on a 24 V DC supply and is built for panel-mount installation, with a compact housing suited to space-constrained control cabinet cutouts. Configuration is performed using the ProTool software package.
The OP 5 panel is typically deployed in manufacturing, packaging, and process automation environments where simple text-based status display and parameter entry are sufficient. It is well-suited for retrofitting or maintaining legacy SIMATIC S5-based machinery where replacement of the entire control system is not feasible. Its rugged membrane keypad and industrial-grade construction make it appropriate for factory floor environments with moderate environmental demands.
Technical Specifications
| Display Type | LCD text display |
|---|---|
| Display Lines | 4 lines |
| Characters per Line | 20 characters |
| Input/Operating Voltage | 24 V DC |
| Communication Interface | MPI, TTY (20 mA current loop) |
| Mounting | Panel mount (flush mounting) |
| IP Protection Rating (Front) | IP 65 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| Configuration Software | ProTool |
| PLC Compatibility | SIMATIC S5, SIMATIC S7 |
| Series/Product Family | SIMATIC OP 5 |
Common Error Codes & System Events
- System Error 1
- Communication error between the OP 5 and the connected PLC. The connection to the controller has been lost or interrupted.
Check the MPI or TTY cable connections and termination resistors. Verify PLC is powered and running. Check baud rate and address settings on both devices. - System Error 2
- Configuration data error. The project data loaded on the panel is corrupted or incompatible with the connected PLC.
Reload the project from ProTool to the operator panel. Verify the correct PLC type and communication parameters are configured in the project. - System Error 3
- Overflow of the alarm or message buffer. Too many unacknowledged messages are pending.
Acknowledge pending alarms on the panel. Review the alarm configuration in ProTool to ensure buffer sizes are appropriate for the application. - System Error 4
- Download error. Transfer of project data from the programming device to the OP 5 was interrupted or failed.
Check the data transfer cable and connections. Restart the download process from ProTool. Ensure the panel is in transfer mode before initiating download. - System Error 5
- Internal device fault. The panel has detected an internal hardware or firmware error.
Cycle power to the operator panel. If the fault persists, the panel may require repair or replacement of internal components. - No Connection to PLC
- The operator panel cannot establish communication with the configured PLC at startup or during operation.
Verify MPI address settings, cable integrity, and that the PLC is in RUN mode. Check that the MPI network termination is correctly applied at both ends of the bus. - Checksum Error
- The stored project or firmware data has failed an internal checksum verification, indicating possible data corruption.
Re-download the project configuration using ProTool. If the error persists, perform a factory reset and reload both firmware and project data.
Frequently Asked Questions
What PLC families are compatible with the SIMATIC OP 5 (6AV5583-1AB20-0AB0)?
The OP 5 is compatible with Siemens SIMATIC S5 PLCs via the TTY (20 mA current loop) interface and SIMATIC S7 PLCs via the MPI interface. The specific communication driver must be configured in the ProTool project.
What software is used to configure and program the OP 5 panel?
The OP 5 is configured using Siemens ProTool software. WinCC flexible is not compatible with this older panel generation.
What is the supply voltage for the 6AV5583-1AB20-0AB0?
The panel operates on a 24 V DC supply voltage, which is the standard for SIMATIC operator panels of this generation.
What is the front panel protection rating of the OP 5?
The front panel of the OP 5 achieves IP 65 protection, making it resistant to dust ingress and low-pressure water jets when correctly installed in a panel cutout.
Can the OP 5 display graphics or only text?
The SIMATIC OP 5 is a text-based operator panel only. It displays alphanumeric characters and does not support graphical content or bitmap images.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the panel's power connector. Check for blown internal fuses or a faulty power supply connection.
Ensure the 24 V DC supply is within tolerance and correctly wired. Replace any blown fuses. If the supply is correct and the display remains blank, the internal power supply or display module may require repair or replacement.
Panel shows 'No Connection' or communication error at startup
Check the MPI or TTY cable for physical damage and secure connections at both the panel and PLC ends. Verify the MPI address and baud rate configured on the OP 5 match the PLC network settings.
Replace or reseat the communication cable. Correct the MPI address and baud rate in the ProTool project and re-download. Ensure bus termination resistors are active only at the two physical ends of the MPI network.
Project download from ProTool fails or is interrupted
Verify the data transfer cable between the programming device and the OP 5 is intact. Confirm the panel is set to transfer mode before initiating the download from ProTool.
Replace the transfer cable if damaged. Restart the panel in transfer mode and retry the download. Ensure the ProTool version is compatible with the OP 5 firmware version.
Operator keypad buttons are unresponsive or intermittent
Inspect the membrane keypad for physical damage, contamination, or wear. Check the internal ribbon cable connection between the keypad membrane and the main PCB.
Clean the keypad surface with a dry cloth. If the ribbon cable is loose, reseat it carefully. A worn or damaged membrane keypad will require replacement of the keypad assembly.
Panel repeatedly resets or reboots during operation
Check the stability of the 24 V DC power supply under load. Inspect for loose wiring at the power connector and verify the supply voltage does not drop below the minimum threshold during operation.
Stabilize the power supply and ensure adequate current capacity. Secure all wiring connections. If the rebooting continues with a stable supply, the panel's internal electronics may require inspection and repair.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page



