• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV5030-1DL20-0AC0 SIMATIC WinCC flexible
    Awaiting product image

    Siemens 6AV5030-1DL20-0AC0 SIMATIC WinCC flexible

    € 1.995,00

    Reset
    Clear
    SKU: 6AV5030-1DL20-0AC0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV5030-1DL20-0AC0 is a software license for SIMATIC WinCC flexible 2008, Siemens' engineering software platform for configuring and commissioning HMI (Human-Machine Interface) panels and visualization systems. It belongs to the SIMATIC WinCC flexible product family, which serves as the central engineering environment for the full range of Siemens SIMATIC HMI operator panels, from Micro Panels to Multi Panels and PC-based systems. This software package provides the tools necessary to create, manage, and transfer HMI projects to connected operator panels.

    WinCC flexible 2008 offers a comprehensive set of engineering features including drag-and-drop screen design, tag management, alarm logging, trend displays, recipe management, and script-based automation using VBScript. It supports a wide range of communication drivers enabling connectivity to SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs, as well as third-party controllers via OPC and other standard protocols. The software includes simulation capabilities allowing project validation without physical hardware, and supports multi-language project configuration for international deployments.

    This software is used across a broad range of industrial sectors including manufacturing, process automation, food and beverage, automotive, and building automation. It is the standard engineering tool for commissioning Siemens SIMATIC HMI panels such as the TP177, OP177, MP277, and MP377 series, making it essential for system integrators, OEMs, and maintenance engineers working with Siemens HMI infrastructure. Its structured project management and version control features make it suitable for complex multi-panel installations.

    Technical Specifications

    Software Type HMI Engineering Software
    Product Family SIMATIC WinCC flexible 2008
    License Type Single-user license
    Compatible HMI Panels SIMATIC Micro Panels, OP/TP 170, OP/TP 177, MP 277, MP 377, Multi Panels
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400, S7-1200, third-party via OPC
    Communication Protocols MPI, PROFIBUS DP, PROFINET, OPC, Modbus
    Scripting Support VBScript
    Simulation Integrated HMI simulator included
    Operating System Windows XP Professional, Windows Vista, Windows 7
    Multi-language Support Yes, multi-language project configuration
    Recipe Management Supported
    Alarm Logging Supported
    Trend Display Supported
    Certifications CE

    Common Error Codes & System Events

    Error 1
    License not found or invalid license key detected during startup
    Verify the license dongle is correctly inserted or re-activate the software license using the Siemens Automation License Manager (ALM).
    Error 2
    Communication driver not installed or missing for target HMI panel
    Reinstall the communication driver via the WinCC flexible installation media and ensure the correct driver version is selected for the target panel type.
    Error 3
    Project compilation error due to inconsistent tag references
    Open the project in WinCC flexible, navigate to the tag editor, and resolve all unlinked or duplicate tag references before recompiling.
    Error 4
    Transfer to HMI panel failed — connection timeout
    Check the physical communication cable (USB, MPI, or Ethernet), verify the panel is in transfer mode, and confirm the correct interface is selected in the transfer settings.
    Error 5
    Simulation aborted — runtime error in VBScript
    Review the VBScript code in the affected screen or function for syntax errors or unsupported function calls and correct accordingly.
    Error 6
    Incompatible project version detected when opening existing project
    Use the WinCC flexible migration tool to convert the project to the current version, or open the project with the matching software version.
    Error 7
    Automation License Manager (ALM) reports license expired or not activated
    Launch the Siemens Automation License Manager, check the license status, and transfer or reactivate a valid license from the license storage medium.

    Frequently Asked Questions

    Which HMI panels are compatible with WinCC flexible 2008 (6AV5030-1DL20-0AC0)?

    WinCC flexible 2008 supports the full range of SIMATIC HMI panels including Micro Panels, OP/TP 170, OP/TP 177, MP 277, MP 377, and Multi Panel series. It does not support the newer SIMATIC Comfort Panels, which require WinCC (TIA Portal).

    Is a hardware dongle required to run this software?

    Yes, SIMATIC WinCC flexible 2008 requires a valid license managed through the Siemens Automation License Manager (ALM). The license is typically stored on a USB dongle or transferred to the engineering PC's hard drive.

    Can WinCC flexible 2008 communicate with S7-1200 PLCs?

    Yes, WinCC flexible 2008 supports communication with SIMATIC S7-1200 PLCs via PROFINET/Ethernet using the appropriate communication driver.

    Does this software include a simulation function for testing HMI projects without hardware?

    Yes, WinCC flexible 2008 includes an integrated simulator that allows engineers to test and validate HMI screens and logic on the engineering PC without requiring a physical panel or PLC connection.

    Is WinCC flexible 2008 compatible with Windows 10?

    WinCC flexible 2008 is officially supported on Windows XP Professional, Windows Vista, and Windows 7. It is not officially certified for Windows 10, and compatibility issues may arise on newer operating systems.

    Troubleshooting

    Software fails to start and displays a license error on launch

    Check whether the Automation License Manager (ALM) detects a valid license. Open ALM and inspect the license status for the WinCC flexible runtime or engineering license.

    Insert the license USB dongle if missing, or use ALM to transfer a valid license from the storage medium to the engineering PC. Reinstall ALM if it fails to detect the dongle.

    Project transfer to HMI panel fails repeatedly

    Verify the communication interface settings in the transfer dialog match the physical connection type (USB, MPI, PROFIBUS, or Ethernet). Check that the HMI panel is set to transfer mode and the cable is functional.

    Replace the communication cable if faulty, select the correct COM port or network interface in the transfer settings, and ensure the panel firmware version is compatible with the project version.

    Compilation errors appear when building the HMI project

    Navigate to the output window in WinCC flexible to identify the specific error messages. Common causes include unresolved tag references, missing images, or invalid screen object properties.

    Resolve all flagged errors in the tag editor and screen editor. Delete and re-create corrupted objects if necessary, and ensure all external image files referenced in the project are present in the project directory.

    Existing project opens with missing screens or corrupted data

    The project file may have been created with a different version of WinCC flexible or may be corrupted. Check the project version in the project properties.

    Use the WinCC flexible migration wizard to upgrade the project to the current version. If corruption is suspected, restore from a backup or use the project repair function if available.

    Communication between WinCC flexible and PLC fails during runtime simulation

    Check the configured PLC connection parameters in the project, including IP address, rack, and slot settings. Verify that the PC firewall is not blocking the communication port.

    Correct the connection parameters in the connections editor to match the actual PLC configuration. Disable or configure the Windows firewall to allow WinCC flexible communication traffic on the relevant ports.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart