• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV4530-1BC05-3AB0 SIMATIC OP5
    Awaiting product image

    Siemens 6AV4530-1BC05-3AB0 SIMATIC OP5

    € 1.995,00

    Reset
    Clear
    SKU: 6AV4530-1BC05-3AB0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV4530-1BC05-3AB0 is an operator panel (OP5) belonging to the SIMATIC HMI family, designed for human-machine interface applications in industrial automation environments. This unit provides a compact, text-based operator interface for monitoring and controlling programmable logic controllers and automated systems. It is part of Siemens' established SIMATIC OP series, which has been widely deployed across a broad range of industrial sectors.

    The OP5 features a single-line or multi-line LCD text display capable of showing alphanumeric characters, enabling operators to read process values, status messages, and alarm texts. It communicates with Siemens SIMATIC S5 and S7 PLCs via the MPI or point-to-point (PtP) serial interface, and is configured using the ProTool configuration software. The panel includes function keys for direct operator input and is housed in a robust enclosure suitable for panel mounting, with a front face rated for protection against dust and water ingress.

    The SIMATIC OP5 is typically used in manufacturing, process automation, and machine tool applications where a cost-effective, straightforward text-based operator interface is required. It is well suited for smaller machines and control cabinets where display of process parameters, setpoint entry, and alarm acknowledgment are the primary operator tasks. Industries such as food and beverage, packaging, and general factory automation have commonly deployed this panel as a front-end interface to SIMATIC PLCs.

    Technical Specifications

    Display Type LCD text display
    Communication Interface MPI, Point-to-Point (RS-232/RS-422)
    Input/Operating Voltage 24 V DC
    IP Rating (Front) IP65
    Mounting Panel mounting
    Series/Product Family SIMATIC OP5
    Compatible PLCs SIMATIC S5, SIMATIC S7
    Configuration Software ProTool
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +70 °C
    Relative Humidity 10% to 90% (non-condensing)
    Certifications CE, UL

    Common Error Codes & System Events

    System Error 1
    Communication error between OP5 and connected PLC. The panel cannot establish or maintain a connection to the controller.
    Check MPI or serial cable connections and termination resistors. Verify PLC address settings match the OP5 configuration. Restart both devices.
    System Error 2
    Configuration data error or missing project data in the operator panel.
    Re-download the ProTool project to the OP5 using the configuration PC. Verify the correct project file is being transferred.
    System Error 3
    Internal memory error detected during self-test at startup.
    Perform a complete reset of the OP5 and re-download the project. If the error persists, the internal memory or hardware may require replacement.
    System Error 4
    Watchdog timeout — the panel's internal watchdog has triggered due to a software or communication hang.
    Power cycle the OP5. If the fault recurs, check for excessive noise on the communication lines and verify grounding of the panel and cabinet.
    PLC Not Responding
    The OP5 has lost communication with the PLC during operation.
    Check the MPI or PtP cable integrity and connector seating. Verify PLC is in RUN mode and that the configured station address is correct.
    Overflow
    A process value or variable has exceeded the configured display range.
    Check the source variable in the PLC program and verify the scaling and limits configured in the ProTool project are appropriate for the process values being transmitted.
    No Project
    No valid configuration project is loaded in the operator panel.
    Connect a configuration PC with ProTool installed and download a valid project to the OP5. Ensure the transfer cable and COM port settings are correct.

    Frequently Asked Questions

    Which PLCs is the SIMATIC OP5 (6AV4530-1BC05-3AB0) compatible with?

    The OP5 is compatible with Siemens SIMATIC S5 and SIMATIC S7 PLCs, communicating via MPI or point-to-point serial interfaces. The specific protocol and connection type depends on the configuration set up in ProTool.

    What software is used to configure the OP5 panel?

    The OP5 is configured using Siemens ProTool configuration software. Projects are created on a PC and then downloaded to the panel via a serial transfer cable.

    What is the supply voltage for the 6AV4530-1BC05-3AB0?

    The OP5 operates on a 24 V DC supply voltage, which is standard for SIMATIC HMI panels of this generation.

    What is the front panel protection rating of the OP5?

    The front face of the OP5 is rated IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for industrial panel door mounting.

    Can the OP5 display graphical content or images?

    No, the OP5 is a text-based operator panel and is limited to alphanumeric character display. It does not support graphical or bitmap image display.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the panel's power connector using a multimeter. Verify the supply is within tolerance and that the connector is fully seated.

    Restore correct 24 V DC supply. If voltage is present and display remains blank, inspect the internal backlight and power supply board. The unit may require repair or backlight replacement.

    OP5 shows 'PLC Not Responding' or communication error at startup

    Verify the MPI or serial cable is correctly connected at both the OP5 and PLC ends. Check that the PLC station address configured in ProTool matches the actual PLC address setting.

    Replace or reseat the communication cable. Correct any address mismatches in the ProTool project and re-download. Ensure MPI bus termination is correctly applied at both ends of the bus.

    Project download from PC to OP5 fails

    Check the serial transfer cable connection between the PC and the OP5 transfer port. Verify the correct COM port is selected in ProTool and that the baud rate settings match.

    Try a different COM port or USB-to-serial adapter. Ensure the OP5 is in transfer mode before initiating the download. Re-install ProTool drivers if the PC does not recognise the connection.

    Function keys do not respond to operator input

    Inspect the keypad membrane for physical damage, contamination, or deformation. Test each key systematically using a diagnostic screen in the ProTool project if available.

    Clean the keypad surface. If keys remain unresponsive, the keypad membrane assembly may need replacement. Contact a repair specialist for membrane or PCB-level repair.

    Alarm messages are not displayed or acknowledged correctly

    Review the alarm configuration in the ProTool project to verify alarm bit addresses match the corresponding PLC data words. Check PLC program logic for correct alarm bit setting and resetting.

    Correct any address mismatches in the ProTool alarm configuration and re-download the project. Verify PLC program sets and resets alarm bits as expected during testing.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart