• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • Drive
    • 6SE7021-3TP50-Z SIMOVERT MASTERDRIVES
    Awaiting product image

    6SE7021-3TP50-Z SIMOVERT MASTERDRIVES

    Reset

    This product is currently out of stock and unavailable.

    SKU: 6SE7021-3TP50-Z Category: Drive
    • Description
    • Additional information

    The Siemens SIMOVERT MASTERDRIVES 6SE7021-3TP50-Z is a vector control AC drive belonging to Siemens' SIMOVERT MASTERDRIVES MC (Motion Control) and VC (Vector Control) series. This unit is designed for variable-speed control of three-phase asynchronous and synchronous motors, offering precise speed and torque regulation in demanding industrial environments. The 6SE7021-3TP50-Z variant is a compact chassis-mounted inverter unit rated for a power output in the 7.5 kW range at 400 V AC supply.

    The SIMOVERT MASTERDRIVES series features a modular hardware architecture allowing integration of optional communication boards, technology boards, and encoder evaluation modules. The drive supports multiple control modes including V/f control, sensorless vector control, and closed-loop field-oriented vector control. It includes a built-in DC bus interface enabling multi-axis configurations with shared DC link, integrated brake chopper capability, and comprehensive protection functions such as overcurrent, overvoltage, undervoltage, and overtemperature monitoring. Parameterization is performed via the PMU operator panel or through SIMATIC STEP 7 / DriveMonitor software using the USS or PROFIBUS-DP interface.

    The 6SE7021-3TP50-Z is widely deployed in machine tool spindle drives, conveyor systems, hoisting equipment, pumps, fans, and compressors across the automotive, steel, paper, and general manufacturing industries. Its closed-loop vector control capability makes it suitable for applications requiring high dynamic response and precise torque control at low speeds. The shared DC bus architecture is particularly advantageous in multi-axis machinery where regenerative energy from braking axes can be reused by motoring axes.

    Technical Specifications

    Series SIMOVERT MASTERDRIVES VC
    Input Voltage 380 – 480 V AC, 3-phase
    Output Power 7.5 kW
    Output Current (Continuous) 13 A
    Input Frequency 47 – 63 Hz
    Control Type V/f, sensorless vector control, closed-loop field-oriented vector control
    Communication Interface USS (RS-485); optional PROFIBUS-DP via CB board
    Switching Frequency 2.5 – 16 kHz (adjustable)
    Operating Temperature 0 °C to +40 °C (derating above 40 °C)
    Storage Temperature -25 °C to +70 °C
    Relative Humidity ≤ 95 % (non-condensing)
    Protection Rating IP20
    Mounting Chassis (panel mounting)
    Braking Resistor Support Yes, integrated brake chopper
    Certifications CE, UL, cUL

    Common Fault Codes

    F001
    Overcurrent: Output current has exceeded the permissible limit, typically caused by a short circuit, motor fault, or excessively fast acceleration ramp.
    Check motor wiring for short circuits, verify motor data parameters, and extend the acceleration ramp time (P462/P464).
    F002
    Overvoltage: DC link voltage has exceeded the maximum permissible level, often caused by regenerative energy during deceleration.
    Extend the deceleration ramp time (P464), verify the braking resistor connection, or enable the Vdc-max controller.
    F003
    Undervoltage: DC link voltage has dropped below the minimum threshold, indicating a supply voltage interruption or dip.
    Check the input supply voltage and connections. Verify that the supply is within the rated range of 380–480 V AC.
    F004
    Drive Overtemperature: The heatsink or internal temperature has exceeded the permissible limit.
    Check that cooling fans are operational, ensure adequate ventilation clearances, and verify that the ambient temperature does not exceed 40 °C.
    F005
    Motor Overtemperature: The motor thermal model or PTC/KTY sensor has detected excessive motor temperature.
    Check motor load conditions, verify motor cooling, and check PTC/KTY sensor wiring and parameter settings (P561).
    F011
    Ground Fault: An earth fault has been detected on the output phases.
    Disconnect the motor and check motor winding insulation resistance to earth. Inspect output cabling for insulation damage.
    F023
    Output Phase Failure: One or more output phases are missing or have an open circuit.
    Check motor cable connections at the drive output terminals and at the motor terminal box. Verify cable continuity.
    F025
    PROFIBUS / Communication Fault: Loss of communication on the fieldbus interface board.
    Check PROFIBUS cable connections and termination resistors. Verify master controller is active and check CB board seating in the option slot.

    Frequently Asked Questions

    What is the power rating and output current of the 6SE7021-3TP50-Z?

    The 6SE7021-3TP50-Z is rated for 7.5 kW output power with a continuous output current of approximately 13 A at a 400 V AC supply voltage.

    Does this drive support PROFIBUS-DP communication?

    PROFIBUS-DP is not built in as standard but can be added by installing an optional Communication Board (CB) in the drive's option slot, such as the CBP2 PROFIBUS board.

    Can the 6SE7021-3TP50-Z be connected to a shared DC bus?

    Yes, the SIMOVERT MASTERDRIVES series supports a common DC bus configuration, allowing multiple inverter units to share a DC link so that regenerative energy from braking drives can be utilized by motoring drives.

    What software is used to parameterize this drive?

    The drive can be parameterized using the PMU operator panel directly on the unit, or via a PC using Siemens DriveMonitor or STARTER software connected through the USS/RS-485 serial interface.

    What encoder types are supported for closed-loop vector control?

    Encoder evaluation requires an optional Sensor Module or technology board. The drive supports incremental TTL encoders and, with appropriate option boards, resolver and SSI absolute encoders.

    Troubleshooting

    Drive displays F001 overcurrent fault immediately upon start

    Check output terminals for phase-to-phase or phase-to-earth short circuit. Verify motor insulation resistance with a megohmmeter. Confirm motor nameplate data matches parameters P101–P109.

    Repair any wiring faults or motor insulation failures. Re-enter correct motor data and perform a motor identification run (P115). Extend acceleration ramp time in P462.

    Drive powers up but display shows no output and motor does not run

    Check that the enable signal (terminal 63 or PROFIBUS control word) is active. Verify that the ON/OFF command is being sent correctly. Check for any active fault or alarm codes on the PMU display.

    Ensure all enable and run permissive signals are correctly wired and active. Acknowledge any latched faults using the PMU or via the control word. Check parameter P554 (source of ON command) is set correctly.

    Heatsink overtemperature fault (F004) occurring during normal operation

    Inspect the cooling fan at the base of the drive for rotation and airflow. Check that ventilation clearances above and below the unit are maintained (minimum 100 mm). Measure ambient temperature inside the control cabinet.

    Clean or replace the cooling fan if faulty. Ensure cabinet ventilation is adequate and ambient temperature is within specification. Reduce the switching frequency (P761) to lower heat dissipation if operating near thermal limits.

    Erratic speed or poor torque performance in vector control mode

    Check encoder wiring and shield connections if operating in closed-loop mode. Verify that motor data parameters (P101–P109) are correctly entered. Check if motor identification (P115) has been performed.

    Re-enter accurate motor nameplate data and repeat the motor identification routine. Inspect encoder cable for noise interference and ensure the shield is grounded at one end only. Adjust speed controller gain parameters P235 and P240 if oscillation persists.

    PROFIBUS communication fault (F025) causing drive to trip

    Check the CB board is firmly seated in the option slot. Verify PROFIBUS cable termination at both ends of the network segment. Confirm the drive's PROFIBUS address (P918) matches the master configuration.

    Reseat the CB board and secure the option slot cover. Replace or re-terminate PROFIBUS connectors as needed. Correct the node address in P918 and update the master PLC hardware configuration to match.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Placeholder

      Lenze ESMD751X2SFAXXS22 ESMD751X2SFA

      € 132,00
      Read more
    • Placeholder

      Lenze E94AZPM0044 Lenze 9400 HighLine

      € 122,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Placeholder

      Lenze E84AZESR2222LL Lenze 8400 StateLine

      € 118,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart