Siemens 6AG1647-0AH11-2AX1 SIPLUS HMI KTP400 Basic
€ 325,00
The Siemens SIPLUS HMI 6AG1647-0AH11-2AX1 is a ruggedized variant of the SIMATIC KTP400 Basic panel, belonging to the SIPLUS extreme product line designed for use in harsh and demanding environmental conditions. This 4-inch Basic Panel combines key-and-touch operation and is engineered to withstand extended temperature ranges, increased condensation, and exposure to corrosive atmospheres. It is part of the SIMATIC HMI Basic Panels generation and is configured and operated using the WinCC Basic engineering software integrated in TIA Portal.
The 6AG1647-0AH11-2AX1 features a 4-inch TFT widescreen display with a resolution of 480 x 272 pixels and 64,000 color depth, supporting both touch and 4 function key operation. Communication is provided via a PROFINET interface, enabling direct integration into standard Ethernet-based automation networks. The panel offers 10 MB of user memory for project data, supports Siemens S7-1200 and S7-1500 PLC families, and operates from a 24 V DC supply. As a SIPLUS extreme variant, it is coated and treated to resist condensation, corrosive gases, and biological influences beyond the standard SIMATIC specification.
This panel is commonly deployed in industries such as chemical processing, water and wastewater treatment, food and beverage, and offshore or marine environments where standard HMI panels would be susceptible to environmental degradation. Its ruggedized design makes it suitable for installation in control cabinets exposed to high humidity, temperature fluctuations, and chemically aggressive atmospheres. The compact 4-inch form factor and combined key-and-touch interface make it well suited for machine-level operator panels where space is limited and reliable operation under adverse conditions is required.
Technical Specifications
| Display Size | 4 inch |
|---|---|
| Display Resolution | 480 x 272 pixels |
| Display Colors | 64,000 colors (16-bit) |
| Display Type | TFT widescreen |
| Touch Technology | Resistive touch + 4 function keys |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Typically 2.3 W |
| Communication Interface | PROFINET (1x RJ45) |
| User Memory | 10 MB |
| Operating Temperature | -20 °C to +60 °C |
| Storage Temperature | -40 °C to +70 °C |
| Relative Humidity | 5% to 95% (with condensation, SIPLUS extreme) |
| IP/Protection Rating | IP65 (front), IP20 (rear) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIPLUS extreme / SIMATIC HMI Basic Panels |
Common Error Codes & System Events
- Event ID: 10000
- Configuration error detected on the HMI device. Project data may be corrupt or incompatible with the firmware version.
Re-download the project from TIA Portal ensuring firmware version compatibility. Check project integrity in WinCC Basic. - Event ID: 20000
- Communication connection to the configured PLC has been lost or cannot be established.
Check PROFINET cable and connector integrity. Verify IP address configuration of both HMI and PLC. Confirm PLC is in RUN mode. - Event ID: 30000
- Internal device error or hardware fault detected.
Perform a factory reset via the Start Center. If the fault persists, the device may require repair or replacement. - Event ID: 40000
- User memory is full. No further data logging or alarm logging is possible.
Reduce the size of the project, clear data logs, or increase the allocated memory for logging in the TIA Portal project settings. - Event ID: 50000
- Firmware update failed or firmware version mismatch detected.
Retry the firmware update using the correct firmware package for this panel variant via TIA Portal or a USB transfer. - Event ID: 60000
- Tag or variable address in the project cannot be resolved or is invalid.
Check all PLC tag addresses referenced in the HMI project in TIA Portal. Recompile and re-download the project after correcting invalid addresses. - Event ID: 70000
- Screensaver or backlight timeout has activated, display appears off.
Touch the screen or press a function key to wake the panel. Adjust screensaver settings in the HMI device settings if required.
Frequently Asked Questions
Which PLC families are compatible with the SIPLUS HMI 6AG1647-0AH11-2AX1?
This panel is compatible with Siemens S7-1200 and S7-1500 PLC families via PROFINET. It is configured using WinCC Basic within the TIA Portal engineering environment.
What makes the SIPLUS variant different from the standard SIMATIC KTP400 Basic?
The SIPLUS extreme variant is treated with a conformal coating and additional protective measures to withstand condensation, corrosive gases, and biological influences. It also supports an extended operating temperature range of -20 °C to +60 °C compared to the standard panel.
What engineering software is required to program this HMI panel?
The panel is configured using WinCC Basic, which is integrated into the Siemens TIA Portal engineering framework. A minimum TIA Portal version compatible with the panel firmware is required.
What communication interface does this panel support?
The 6AG1647-0AH11-2AX1 features a single PROFINET interface via an RJ45 connector for PLC communication and project download.
What is the supply voltage for this panel?
The panel operates on a 24 V DC supply voltage, which is standard for SIMATIC HMI Basic Panels.
Troubleshooting
Display remains blank after power on
Check that 24 V DC is present at the supply connector. Measure voltage at the panel terminals and verify polarity. Check whether the power LED is illuminated.
Correct any wiring issues or supply voltage faults. If voltage is correct and the display remains blank, the internal power supply or backlight may be faulty and the unit should be sent for repair.
HMI cannot establish communication with the PLC
Verify the PROFINET cable is connected to the RJ45 port. Check the IP address settings on both the HMI (via Start Center) and the PLC. Use a network scanner to confirm both devices are visible on the network.
Correct IP address conflicts or subnet mismatches. Replace the PROFINET cable if damaged. Ensure the PLC project has the HMI device correctly configured in the network view in TIA Portal.
Touchscreen does not respond or responds inaccurately
Check for physical damage or contamination on the display surface. Attempt to recalibrate the touch screen via the Start Center settings menu.
Clean the display surface with a soft, dry cloth. Perform a touch screen recalibration. If the issue persists, the resistive touch panel may be damaged and require hardware replacement.
Project download from TIA Portal fails
Verify the PC and HMI are on the same network subnet. Check that the correct device IP address is entered in TIA Portal. Confirm the panel is in transfer mode via the Start Center.
Set the HMI to transfer mode manually via the Start Center. Correct any IP address or subnet configuration errors. Ensure the TIA Portal project firmware version matches the panel firmware version.
Panel repeatedly restarts or enters a boot loop
This may indicate a corrupt project file or a firmware issue. Observe whether the panel reaches the Start Center before restarting, which would suggest a project-level fault rather than a hardware fault.
Boot into the Start Center and delete the existing project, then re-download a validated project from TIA Portal. If the boot loop occurs before reaching the Start Center, perform a firmware recovery using a USB memory stick with the correct firmware image.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page