• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV2124-1QC02-0AX1 SIMATIC HMI TP700 Comfort
    Awaiting product image

    Siemens 6AV2124-1QC02-0AX1 SIMATIC HMI TP700 Comfort

    € 1.650,00

    Reset
    Clear
    SKU: 6AV2124-1QC02-0AX1 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens SIMATIC HMI TP700 Comfort (part number 6AV2124-1QC02-0AX1) is a 7-inch widescreen touch panel belonging to the SIMATIC Comfort Panel series. It is designed for high-performance human-machine interface applications and serves as a primary operator interface for industrial automation systems. The panel integrates seamlessly within the Siemens TIA Portal engineering framework, enabling efficient configuration and commissioning.

    The TP700 Comfort features a 7-inch TFT widescreen display with a resolution of 800 x 480 pixels and 16 million colors, providing clear and detailed visualization. It supports both PROFINET and MPI/PROFIBUS communication interfaces, allowing flexible integration into various network architectures. The panel includes 12 MB of user memory, supports USB host and device ports, and offers an SD card slot for data logging and project storage. The resistive touch screen technology ensures reliable operation even in demanding industrial environments, and the unit carries CE, UL, and cULus certifications.

    The SIMATIC TP700 Comfort is widely deployed in manufacturing, automotive, food and beverage, pharmaceutical, and process industries. It is typically used as an operator panel on machinery, production lines, and process control stations where a compact yet capable display interface is required. Its compatibility with Siemens S7-300, S7-400, S7-1200, and S7-1500 PLCs makes it a versatile choice for both new installations and system upgrades.

    Technical Specifications

    Display Size 7 inch (widescreen)
    Display Resolution 800 x 480 pixels
    Display Colors 16,777,216 (16 million)
    Display Type TFT LCD
    Touch Technology Resistive
    Input/Operating Voltage 24 V DC
    Power Consumption Typical 8 W
    User Memory 12 MB
    Communication Interface PROFINET (RJ45), MPI/PROFIBUS DP (RS-422/485), USB 2.0 (host and device)
    Memory Card Slot SD card slot
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Dimensions (W x H x D) 214 x 158 x 46 mm
    Panel Cutout 197 x 141 mm
    Certifications CE, UL, cULus
    Mounting Panel mounting

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between HMI panel and PLC. The connection to the configured controller has been lost or cannot be established.
    Check PROFINET or PROFIBUS cable connections and termination resistors. Verify PLC IP address or MPI/DP address settings match the HMI project configuration. Restart both the HMI and PLC if necessary.
    Event ID: 10001
    Tag read/write error. The HMI is unable to read from or write to a configured PLC tag.
    Verify the tag address exists in the PLC program and that the data type matches the HMI configuration. Check communication link integrity and PLC operating state.
    Event ID: 20000
    Project download error. A project transfer from the engineering PC to the HMI panel has failed.
    Ensure the HMI is in transfer mode. Verify the network or USB connection between the PC and the HMI. Check that the TIA Portal project is compiled without errors before transfer.
    Event ID: 40000
    System memory low. Available user memory on the HMI panel is critically low.
    Delete unused projects, log files, or recipe data from the panel memory. Archive data to an SD card and clear internal storage.
    Event ID: 50000
    SD card error. The SD card inserted in the panel is not recognized or cannot be accessed.
    Remove and reinsert the SD card. Verify the card is formatted as FAT32 and is not write-protected. Replace the SD card if the error persists.
    Event ID: 70000
    Backup/restore error. A backup or restore operation on the HMI panel has failed.
    Ensure sufficient free memory is available. Verify the SD card or USB storage device is properly inserted and formatted. Retry the backup or restore operation.
    Event ID: 110000
    Illegal system state detected. The HMI runtime has encountered an unexpected internal error.
    Perform a controlled restart of the HMI panel. If the error recurs, reload the project via TIA Portal and update the HMI firmware to the latest compatible version.

    Frequently Asked Questions

    What PLC families are compatible with the TP700 Comfort 6AV2124-1QC02-0AX1?

    The TP700 Comfort is compatible with Siemens S7-300, S7-400, S7-1200, and S7-1500 PLCs via PROFINET or MPI/PROFIBUS DP. It is configured and programmed using Siemens TIA Portal.

    What communication interfaces does the TP700 Comfort support?

    The panel supports PROFINET via an RJ45 Ethernet port and MPI/PROFIBUS DP via an RS-422/RS-485 interface. It also includes USB 2.0 host and device ports for peripherals and project transfer.

    What software is required to program the TP700 Comfort?

    The TP700 Comfort is engineered using Siemens TIA Portal with the WinCC (TIA Portal) HMI configuration software. A compatible TIA Portal version must be used to create and download projects to the panel.

    What is the supply voltage for the TP700 Comfort?

    The panel operates on 24 V DC supply voltage. Ensure the power supply is within the specified tolerance range to avoid damage or operational faults.

    Can the TP700 Comfort log data and recipes?

    Yes, the TP700 Comfort supports data logging and recipe management. Data can be stored internally or on an SD card inserted into the panel's memory card slot.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the panel's power connector. Check that the supply is within tolerance and that the connector is fully seated.

    Restore correct 24 V DC supply. If voltage is correct but display remains blank, check internal fuse and inspect the panel for signs of hardware failure. A faulty backlight or internal power board may require panel repair or replacement.

    HMI cannot communicate with the PLC over PROFINET

    Verify the Ethernet cable connection between the HMI and PLC or network switch. Check the IP address configured in the HMI project matches the actual PLC IP address. Use a network scanner to confirm both devices are visible on the network.

    Correct any IP address mismatches in TIA Portal and reload the project. Replace the Ethernet cable if faulty. Ensure the PLC is in RUN mode and that no firewall or switch configuration is blocking communication.

    Touch screen is unresponsive or inaccurate

    Check for physical damage or contamination on the touch screen surface. Determine if the issue is present across the entire screen or only in specific areas.

    Clean the touch screen surface with a soft, dry cloth. Perform a touch screen recalibration via the panel's Control Panel settings. If the screen remains unresponsive, the touch foil or controller board may require replacement.

    Project transfer from TIA Portal fails

    Confirm the HMI is set to transfer mode. Check the network or USB connection between the engineering PC and the HMI. Verify TIA Portal project compiles without errors.

    Switch the HMI to transfer mode via the Start Center. Ensure the PC and HMI are on the same network subnet if using PROFINET transfer. Retry the download; if it fails repeatedly, reset the HMI to factory settings and attempt transfer again.

    SD card not recognized by the panel

    Check that the SD card is fully inserted into the slot. Verify the card format and capacity are within the panel's supported specifications.

    Remove and reinsert the SD card. Format the card as FAT32 on a PC if not already done. Replace the SD card with a compatible one if the panel still does not recognize it.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart