Siemens 6AV2124-5GC00-0WF0 SIMATIC HMI TP900 Comfort
€ 549,00
The Siemens 6AV2124-5GC00-0WF0 is a 9-inch widescreen Touch Panel belonging to the SIMATIC HMI Comfort Panel series. It is designed for high-performance human-machine interface applications and provides a wide-format display with advanced visualization capabilities. This panel is part of Siemens' premium HMI line, offering robust hardware suited for demanding industrial environments.
The 6AV2124-5GC00-0WF0 features a 9-inch widescreen TFT display with a resolution of 800 x 480 pixels and 16 million colors, delivering clear and detailed process visualization. It is equipped with a resistive touch screen and supports a broad range of communication interfaces including PROFINET, PROFIBUS, Ethernet, USB, and serial interfaces (RS-422/485). The panel includes 24 MB user memory for project data, supports Sm@rtAccess and Sm@rtService for remote monitoring, and runs on the Windows CE 6.0 operating system. It operates on a 24 V DC supply and carries protection ratings suitable for front-panel mounting in control cabinets.
The TP900 Comfort Panel is widely used in machine building, process automation, and factory automation across industries such as automotive, food and beverage, packaging, and chemical processing. Its widescreen format and high color depth make it suitable for complex process visualization, trend displays, and alarm management. The panel integrates seamlessly with Siemens SIMATIC S7 PLCs and is configured using the TIA Portal engineering framework.
Technical Specifications
| Display Size | 9 inch (widescreen) |
|---|---|
| Display Resolution | 800 x 480 pixels |
| Display Colors | 16,777,216 (16 million) |
| Display Type | TFT LCD |
| Touch Technology | Resistive |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 18 W |
| User Memory | 24 MB |
| Communication Interface | PROFINET (2x RJ45), PROFIBUS (RS-485), 2x USB, 1x RS-422/485 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Mounting | Panel mounting (portrait and landscape) |
| Certifications | CE, UL, cULus |
| Operating System | Windows CE 6.0 |
| Series/Product Family | SIMATIC HMI Comfort Panel |
Common Error Codes & System Events
- Event ID: 70010
- Connection to the PLC could not be established or was interrupted during runtime.
Check PROFINET or PROFIBUS cable connections and verify PLC IP address or station address settings in the project configuration. Ensure the PLC is in RUN mode. - Event ID: 40000
- Project download failed or project data is corrupted on the panel.
Re-download the project from TIA Portal. Ensure the firmware version of the panel matches the TIA Portal version used. Check USB or Ethernet connection during transfer. - Event ID: 1003
- System memory (RAM) is running low during runtime operation.
Reduce the number of simultaneously active screens or objects. Optimize the project by limiting background tasks and reducing image file sizes. - Event ID: 20000
- Tag communication error — a configured tag cannot be read from or written to the controller.
Verify the tag address in TIA Portal matches the actual PLC data block or memory address. Check PLC program for address changes. - Event ID: 50010
- Recipe data transfer error — recipe could not be read from or written to the controller.
Check recipe configuration in TIA Portal. Verify that the target PLC data block exists and has sufficient size. Re-download the project if necessary. - Event ID: 80010
- Alarm logging error — alarm events could not be written to the configured storage location.
Check that the target storage medium (USB drive or SD card) is inserted and has sufficient free space. Verify alarm archive configuration in TIA Portal. - Event ID: 60010
- Screen object rendering error — one or more display objects cannot be shown correctly.
Check for unsupported object types or version mismatches between TIA Portal and panel firmware. Update panel firmware to match the project version.
Frequently Asked Questions
What PLC systems is the 6AV2124-5GC00-0WF0 compatible with?
The TP900 Comfort Panel is primarily designed for use with Siemens SIMATIC S7-300, S7-400, S7-1200, and S7-1500 PLCs via PROFINET or PROFIBUS. It can also communicate with third-party controllers using OPC, Modbus TCP, or serial protocols.
What engineering software is required to configure this panel?
The 6AV2124-5GC00-0WF0 must be configured using Siemens TIA Portal with the WinCC (TIA Portal) option package. Older STEP 7 and WinCC flexible software is not compatible with Comfort Panel generation devices.
Does this panel support remote access and monitoring?
Yes, the TP900 Comfort Panel supports Sm@rtAccess and Sm@rtService functions, allowing remote monitoring and control via a standard web browser or the Sm@rtClient application over an Ethernet network.
What is the supply voltage for the 6AV2124-5GC00-0WF0?
The panel operates on a 24 V DC supply voltage. A stable, regulated 24 V DC power supply with sufficient current capacity (typically 1 A or more) is required for reliable operation.
Can the panel be mounted in both landscape and portrait orientation?
Yes, the SIMATIC Comfort Panels including the TP900 support both landscape and portrait mounting orientations, and the display rotation can be configured within the TIA Portal project settings.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the rear power connector. Check that the voltage is within the specified range (19.2 V to 28.8 V DC). Inspect the internal fuse if accessible.
Ensure the power supply provides stable 24 V DC with adequate current. If the supply is correct and the display remains blank, the internal power supply board or backlight inverter may be faulty and the unit should be sent for repair.
Touch input is unresponsive or inaccurate
Determine whether the issue is a complete lack of response or positional inaccuracy. Check for physical damage or contamination on the touch surface. Attempt a touch screen recalibration from the panel's Start Center menu.
Clean the touch surface with a soft, dry cloth. Perform a touch recalibration via the Start Center (Control Panel > Touch). If the issue persists, the resistive touch overlay may be damaged and require replacement.
Panel cannot establish communication with the PLC
Verify the PROFINET IP address settings on both the panel and the PLC. Use a network scanner or TIA Portal to confirm the panel is visible on the network. Check Ethernet cable integrity and switch/hub connections.
Correct any IP address conflicts or subnet mismatches in TIA Portal. Replace the Ethernet cable if faulty. Ensure the PLC is in RUN mode and the communication driver in the HMI project is correctly configured.
Project download from TIA Portal fails or times out
Check the Ethernet or USB connection between the engineering PC and the panel. Verify that the panel is in Transfer mode (accessible via Start Center). Confirm that the TIA Portal version matches the panel firmware version.
Switch the panel to Transfer mode manually via the Start Center. Update the panel firmware using the ProSave tool if there is a version mismatch. Try a different USB cable or Ethernet port if the connection is unstable.
Panel reboots unexpectedly during operation
Check the 24 V DC supply for voltage dips or instability under load. Review the panel's alarm and event logs for system error events. Inspect the environment for excessive temperature or vibration.
Install a higher-quality regulated 24 V DC power supply with adequate current reserve. Ensure the panel operating temperature does not exceed 50 °C. If reboots continue without a clear cause, the panel hardware may require inspection and repair.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page