6ES7222-1HF22-0XA0 SIMATIC S7-200
The Siemens SIMATIC S7-200 series is a compact programmable logic controller (PLC) designed for small to medium-scale automation tasks. The 6ES7222-1HF22-0XA0 is a digital output expansion module belonging to the EM 222 family, providing additional discrete output capacity to an S7-200 CPU. It extends the I/O capabilities of the base CPU unit without requiring a separate controller.
The 6ES7222-1HF22-0XA0 module provides 8 digital outputs with relay contact switching, rated at 24 V DC or up to 250 V AC, making it suitable for controlling a wide range of field devices. Each relay output can switch loads up to 2 A per channel, offering electrical isolation between the control logic and the field wiring. The module connects directly to the S7-200 CPU or other expansion modules via the local I/O bus and draws its logic supply from the CPU's internal 5 V DC bus.
This expansion module is commonly used in manufacturing, building automation, material handling, and process control applications where additional relay outputs are required beyond the onboard I/O of the S7-200 CPU. Its relay outputs make it particularly well-suited for switching motors, solenoids, lamps, and other inductive or resistive loads. The compact DIN-rail mountable form factor allows integration into space-constrained control cabinets.
Technical Specifications
| Module Type | Digital Output Expansion Module |
|---|---|
| Series/Product Family | SIMATIC S7-200 EM 222 |
| Number of Digital Outputs | 8 |
| Output Type | Relay |
| Output Voltage (AC) | Up to 250 V AC |
| Output Voltage (DC) | 24 V DC |
| Output Current per Channel | 2 A |
| Isolation | Electrically isolated relay contacts |
| Logic Supply Voltage | 5 V DC (via CPU I/O bus) |
| Operating Temperature | 0 °C to +55 °C |
| Storage Temperature | -40 °C to +70 °C |
| Relative Humidity | 5 % to 95 % (non-condensing) |
| Mounting | DIN rail or panel mounting |
| IP/Protection Rating | IP20 |
| Certifications | CE, UL, cUL |
Common Diagnostic Codes
- Fault Code 1
- CPU configuration error — the expansion module configuration does not match the hardware connected to the CPU.
Verify the hardware configuration in STEP 7 Micro/WIN matches the physical module order and type. Re-download the configuration to the CPU. - Fault Code 2
- I/O bus communication error — the CPU cannot communicate with one or more expansion modules.
Check the I/O expansion cable connections between the CPU and expansion modules. Inspect connectors for damage or corrosion and reseat the module. - Fault Code 3
- Output short circuit or overload detected on a relay output channel.
Disconnect the field wiring from the affected output channel and measure the load. Replace any shorted field devices and verify load current does not exceed 2 A per channel. - Fault Code 4
- Module not recognized — the CPU detects a missing or unresponsive expansion module.
Power down the system, reseat the expansion module, and verify the module is correctly connected in the expansion chain. Replace the module if the fault persists. - Fault Code 5
- Excessive ambient temperature — the module is operating outside its rated temperature range.
Measure cabinet temperature and ensure it does not exceed 55 °C. Improve ventilation or add cooling to the control cabinet. - Fault Code 6
- Output relay coil failure — one or more relay outputs are not switching correctly.
Use a multimeter to verify continuity across the relay contacts when the output is commanded ON. If the relay does not switch, the module requires replacement. - Fault Code 7
- 5 V DC bus undervoltage — insufficient power supplied from the CPU to the expansion module.
Calculate total 5 V DC current consumption of all expansion modules and verify it does not exceed the CPU's rated 5 V bus current. Remove non-essential modules or upgrade to a CPU with higher bus current capacity.
Frequently Asked Questions
How many digital outputs does the 6ES7222-1HF22-0XA0 provide?
The module provides 8 relay digital outputs, each rated at up to 2 A.
What output voltage is supported by this module?
The relay outputs support both AC and DC loads — up to 250 V AC or 24 V DC at up to 2 A per channel.
Which S7-200 CPUs are compatible with this expansion module?
The EM 222 module is compatible with all S7-200 CPU variants, including the CPU 221, CPU 222, CPU 224, CPU 224XP, and CPU 226, subject to the CPU's maximum expansion module count and 5 V bus current budget.
Does this module require an external power supply?
The module draws its 5 V logic supply from the S7-200 CPU's internal I/O bus. However, the relay output load circuits require an external supply appropriate for the connected field devices (24 V DC or up to 250 V AC).
Can this module be used with the S7-1200 or S7-300 series PLCs?
No, the EM 222 expansion modules are designed exclusively for the S7-200 series and are not compatible with S7-1200, S7-300, or other SIMATIC PLC families.
Troubleshooting
Expansion module outputs do not switch on when commanded by the CPU program
Verify the output status in STEP 7 Micro/WIN using the status monitor. Check whether the CPU output image shows the outputs as ON. Measure voltage at the relay output terminals with a multimeter.
If the CPU output image shows ON but the relay does not switch, the relay contact may be failed. Replace the EM 222 module. If the output image shows OFF, review the PLC program logic and ensure the correct output addresses are being used.
CPU reports a configuration mismatch fault after adding the expansion module
Compare the module order and types configured in STEP 7 Micro/WIN with the physical hardware connected to the CPU. Check that the module is seated correctly on the expansion bus.
Correct the hardware configuration in STEP 7 Micro/WIN to match the physical module arrangement and re-download the configuration to the CPU. Power cycle the system after downloading.
Module is not recognized by the CPU after installation
Power down the system and inspect the expansion bus connector between the CPU and the module for bent pins or damage. Verify the module is fully seated and the connector is locked.
Reseat the module firmly and power the system back on. If the module is still not recognized, test with a known-good module to determine whether the fault lies with the module or the CPU expansion port.
Relay outputs switch erratically or fail to hold state
Check for excessive electrical noise on the output load circuits, particularly with inductive loads such as motors or solenoids. Measure supply voltage stability at the CPU and module terminals.
Install snubber circuits or freewheeling diodes across inductive loads connected to the relay outputs. Ensure proper grounding of the control cabinet and separate control wiring from power wiring.
5 V bus current overload indicated by CPU fault LED
Calculate the total 5 V DC current draw of all connected expansion modules. The EM 222 relay module consumes approximately 40 mA from the 5 V bus. Verify the total does not exceed the CPU's rated 5 V bus output current.
Remove non-essential expansion modules to reduce the 5 V bus load. If additional I/O is required, upgrade to an S7-200 CPU with a higher 5 V bus current rating, such as the CPU 224 or CPU 226.