• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • PLC
    • 6ES5777-0BB01 SIMATIC S5
    Awaiting product image

    6ES5777-0BB01 SIMATIC S5

    Reset

    This product is currently out of stock and unavailable.

    SKU: 6ES5777-0BB01 Category: PLC
    • Description
    • Additional information

    The Siemens SIMATIC S5 6ES5777-0BB01 is a module belonging to the classic SIMATIC S5 programmable logic controller family, one of Siemens' foundational industrial automation platforms. The S5 series was designed for robust, reliable control of industrial processes and machinery, and the 6ES5777-0BB01 is a communications or interface module within this well-established product line. This module integrates into the S5 rack-based architecture, enabling expanded connectivity and data exchange capabilities for the controller system.

    The 6ES5777-0BB01 is a CP (Communications Processor) module for the SIMATIC S5 system, supporting serial or network-based communication interfaces typical of the S5 generation. It is designed to operate within the S5 central rack and communicates via the S5 backplane bus, allowing data exchange between the PLC and external devices or networks. The module is built to industrial standards with a wide operating temperature range and is compatible with the STEP 5 programming environment used for S5 controller configuration and diagnostics.

    The SIMATIC S5 series, including the 6ES5777-0BB01, has been widely deployed in manufacturing, process automation, automotive production, chemical plants, and utilities infrastructure. Its modular architecture allows integration into existing S5 installations for system expansion or replacement of aging communications hardware. The module is particularly relevant for maintenance and refurbishment of legacy S5 systems where continued operation of installed equipment is required without full migration to newer platforms.

    Technical Specifications

    Series/Product Family SIMATIC S5
    Module Type Communications Processor (CP)
    Bus System Compatibility SIMATIC S5 backplane bus
    Programming Software STEP 5
    Operating Temperature 0 °C to +60 °C
    Storage Temperature -40 °C to +70 °C
    Relative Humidity 15 % to 95 %, non-condensing
    Mounting S5 central rack / expansion rack
    Certifications CE
    Input/Operating Voltage 5 V DC (via backplane bus)

    Common System Event Codes

    BADF
    Bad configuration or module initialization failure detected during startup self-test.
    Verify module seating in the rack, check STEP 5 configuration parameters, and re-download the hardware configuration.
    BUSF
    Bus fault detected on the S5 backplane bus, indicating a communication error between modules.
    Inspect rack connectors and module contacts for damage or contamination. Re-seat the module and check for other faulty modules in the rack.
    SF (System Fault)
    General system fault indicated by the SF LED on the CPU or module, signaling an internal hardware or firmware error.
    Perform a power cycle. If the fault persists, check the STEP 5 diagnostic buffer for detailed error information and replace the module if hardware failure is confirmed.
    EXTF
    External fault signal received, indicating an error condition reported by a connected external device or network.
    Check the connected external device or network for fault conditions. Verify wiring and communication parameters match the external device configuration.
    FRCE
    Force mode active on the module or associated CPU, which may cause unexpected I/O behavior.
    Disable force mode in STEP 5 and verify that no forced variables remain active before returning the system to normal operation.
    STOP
    Module or CPU has entered STOP state due to a programming error, configuration mismatch, or hardware fault.
    Connect STEP 5 programmer, read the diagnostic buffer, correct the identified fault, and perform a warm or cold restart as appropriate.

    Frequently Asked Questions

    What SIMATIC S5 CPU types is the 6ES5777-0BB01 compatible with?

    The 6ES5777-0BB01 is designed for use within the SIMATIC S5 rack-based system and is compatible with S5-115U, S5-135U, and S5-155U CPUs that support communications processor modules in their expansion racks.

    What programming software is required to configure the 6ES5777-0BB01?

    Configuration and diagnostics for this module are performed using Siemens STEP 5 software, which runs on compatible Windows-based or legacy DOS-based programming devices.

    Can the 6ES5777-0BB01 be used as a direct replacement in an existing S5 installation?

    Yes, provided the rack slot and hardware configuration in STEP 5 are correctly set up to recognize the module type. Always verify the module order number and firmware revision match the system requirements before installation.

    Is the SIMATIC S5 6ES5777-0BB01 still supported by Siemens?

    The SIMATIC S5 product family has been discontinued by Siemens, meaning new production and official support have ended. Spare modules are available through specialist refurbishment and repair suppliers for legacy system maintenance.

    What should be checked if the module fails to communicate after installation?

    Verify correct seating in the rack, confirm the STEP 5 hardware configuration matches the physical slot assignment, check backplane bus connectors for damage, and review the CPU diagnostic buffer for any reported fault codes.

    Troubleshooting

    Module not recognized by the S5 CPU after installation

    Check the STEP 5 hardware configuration to confirm the module is assigned to the correct rack slot. Inspect the module's edge connector and rack slot contacts for contamination or mechanical damage.

    Re-seat the module firmly in the rack slot. Update the STEP 5 hardware configuration to correctly reflect the module type and slot position, then perform a CPU restart.

    SF (System Fault) LED illuminated on the module

    Connect a STEP 5 programming device and read the diagnostic buffer of the CPU to identify the specific fault code and module address causing the system fault.

    Address the fault identified in the diagnostic buffer. This may involve correcting configuration parameters, replacing a faulty module, or repairing wiring faults on connected devices.

    Communication errors between the module and external devices

    Verify communication parameters such as baud rate, parity, and protocol settings in the STEP 5 configuration match those of the connected external device. Check physical wiring and cable integrity.

    Correct any mismatched communication parameters in STEP 5 and re-download the configuration. Replace damaged cables or connectors as required.

    Module operates intermittently or resets unexpectedly

    Measure the 5 V DC backplane bus voltage at the rack. Inspect the rack power supply unit for output voltage stability and check for loose module connections.

    Replace the rack power supply if the 5 V DC output is out of tolerance. Ensure all modules are firmly seated and rack connectors are free from corrosion or mechanical damage.

    Unable to connect with STEP 5 programming software

    Verify the programming cable type and interface adapter are compatible with the S5 CPU being used. Check the PC communication port settings and STEP 5 interface configuration.

    Use the correct S5-compatible programming cable (e.g., PC-TTY adapter). Confirm COM port settings in STEP 5 match the physical interface, and test with a known-good programming cable if available.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Placeholder

      Siemens 6GK7443-5DX03-0XE0 CP 443-5 Extended

      € 333,00
      Read more
    • Placeholder

      Siemens Simatic ET200 6ES7131-1BL11-0XB0

      € 1.017,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Placeholder

      Siemens Simatic S5 6GK1901-0AA00-0AA0

      € 16,45 – € 277,00Price range: € 16,45 through € 277,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart