• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • PLC
    • 6ES7151-1AA02-0AB0 SIMATIC ET 200S
    Awaiting product image

    6ES7151-1AA02-0AB0 SIMATIC ET 200S

    Reset

    This product is currently out of stock and unavailable.

    SKU: 6ES7151-1AA02-0AB0 Category: PLC
    • Description
    • Additional information

    The Siemens SIMATIC ET 200S interface module 6ES7151-1AA02-0AB0 is a PROFIBUS DP interface module belonging to the ET 200S distributed I/O system family. It serves as the communication head for the ET 200S station, connecting the modular I/O station to a PROFIBUS DP network and enabling data exchange between field-level I/O modules and a central PLC controller. This module is designed for use within the SIMATIC automation environment and is compatible with S7-300, S7-400, and other PROFIBUS DP masters.

    The IM 151-1 Standard interface module supports PROFIBUS DP communication at baud rates up to 12 Mbit/s and provides automatic baud rate detection. It features a 9-pin Sub-D PROFIBUS connector interface and supports up to 63 I/O modules per ET 200S station. The module operates on a 24 V DC supply voltage and includes diagnostic LEDs for bus status, power, and error indication. It supports isochronous mode for time-critical applications and is compatible with the full range of ET 200S power modules, digital and analog I/O modules, and technology modules.

    The SIMATIC ET 200S with the 6ES7151-1AA02-0AB0 interface module is widely deployed in manufacturing automation, machine building, automotive assembly lines, and process industries where distributed I/O is required close to the field devices. Its modular architecture allows precise adaptation of I/O capacity to the application, reducing wiring complexity and cabinet space. The compact design and IP20 protection rating make it suitable for installation in control cabinets across a broad range of industrial environments.

    Technical Specifications

    Communication Interface PROFIBUS DP
    Max. Baud Rate 12 Mbit/s
    Input/Operating Voltage 24 V DC
    Current Consumption (from 24 V DC) max. 300 mA
    Max. I/O Modules per Station 63
    PROFIBUS Connector 9-pin Sub-D
    IP/Protection Rating IP20
    Operating Temperature 0 °C to +60 °C
    Storage Temperature -40 °C to +70 °C
    Relative Humidity 10% to 95% (non-condensing)
    Mounting 35 mm DIN rail
    Series/Product Family SIMATIC ET 200S
    Certifications CE, UL, cULus
    Bus System Compatibility PROFIBUS DP V0/V1

    Common System Event Codes

    BF (Bus Fault)
    PROFIBUS DP communication fault detected; the interface module cannot communicate with the DP master.
    Check PROFIBUS cable connections, terminating resistors, and bus address settings. Verify the DP master is operational and the baud rate matches.
    SF (System Fault)
    Internal module fault or configuration mismatch detected in the ET 200S station.
    Check the module configuration in the hardware configuration tool (e.g., STEP 7 or TIA Portal). Replace faulty I/O modules or re-download the hardware configuration.
    EXTF (External Fault)
    A fault has been detected in one or more connected I/O modules within the ET 200S station.
    Identify the faulty module using the diagnostic LEDs on individual I/O modules. Replace the defective module and acknowledge the fault in the PLC program.
    PWR (Power Fault)
    Insufficient or missing 24 V DC supply voltage to the interface module or power module.
    Measure the 24 V DC supply at the power module terminals. Verify the power supply unit output voltage and current capacity.
    Diagnostic Interrupt
    An I/O module within the ET 200S station has generated a diagnostic interrupt indicating a channel-level fault.
    Read the diagnostic data via STEP 7 or TIA Portal. Identify the affected channel and correct the field wiring or replace the module.
    Parameter Assignment Error
    The interface module received incorrect or incomplete parameter data from the DP master during startup.
    Re-download the hardware configuration to the DP master. Ensure the GSD file for the ET 200S matches the installed module configuration.
    Station Failure
    The ET 200S station is not responding on the PROFIBUS network; the DP master reports the station as unavailable.
    Check 24 V DC power supply to the interface module, verify PROFIBUS address switches, and inspect cable continuity. Replace the interface module if power and bus connections are confirmed good.

    Frequently Asked Questions

    What PROFIBUS DP baud rates does the 6ES7151-1AA02-0AB0 support?

    The IM 151-1 Standard interface module supports PROFIBUS DP baud rates from 9.6 kbit/s up to 12 Mbit/s with automatic baud rate detection.

    How many I/O modules can be connected to this interface module?

    Up to 63 I/O modules can be connected per ET 200S station using the 6ES7151-1AA02-0AB0 interface module.

    Is this interface module compatible with TIA Portal and STEP 7?

    Yes, the 6ES7151-1AA02-0AB0 is supported in both SIMATIC STEP 7 (v5.x) and TIA Portal for hardware configuration and diagnostics.

    What supply voltage does the 6ES7151-1AA02-0AB0 require?

    The module requires a 24 V DC supply voltage, typically provided via an ET 200S power module installed at the left end of the station.

    Does this module support isochronous mode operation?

    Yes, the IM 151-1 Standard supports isochronous mode (equidistant PROFIBUS DP cycle), which is required for time-critical motion control and synchronization applications.

    Troubleshooting

    BF LED is lit and the ET 200S station is not communicating on PROFIBUS

    Check the PROFIBUS address set on the rotary switches of the interface module and compare it with the address configured in the hardware configuration. Inspect the PROFIBUS cable for breaks or incorrect termination at both ends of the segment.

    Correct the PROFIBUS node address using the rotary switches on the module. Ensure bus termination resistors are enabled only at the two physical ends of the PROFIBUS segment. Re-seat the PROFIBUS connector and re-download the hardware configuration if necessary.

    SF LED is lit after powering up the station

    A configuration mismatch exists between the actual installed I/O modules and the hardware configuration downloaded to the DP master. Use STEP 7 or TIA Portal to read the station diagnostics and identify which slot is reporting an error.

    Compare the physical module arrangement with the configured slot assignments. Correct the hardware configuration in STEP 7 or TIA Portal and re-download to the DP master, or rearrange the physical modules to match the existing configuration.

    ET 200S station drops off PROFIBUS intermittently

    Intermittent communication loss is typically caused by poor cable shielding, excessive cable length, missing or incorrect bus termination, or electromagnetic interference near the PROFIBUS cable.

    Verify total PROFIBUS segment length does not exceed the limit for the configured baud rate. Ensure cable shielding is properly grounded at one end. Check all connector contacts for corrosion or loose connections and replace suspect cable sections.

    No 24 V DC power to the interface module; PWR LED is off

    Measure the 24 V DC voltage at the power module terminals using a multimeter. Check the upstream power supply unit for overload or shutdown conditions.

    Restore the 24 V DC supply by correcting the power supply unit fault or replacing a blown fuse in the supply circuit. Verify the power module is correctly seated on the DIN rail and making proper contact with the bus connector.

    Interface module does not respond after firmware update or configuration change

    The module may be in an undefined state following an interrupted firmware update or an incompatible configuration download. Check the diagnostic LEDs for any fault pattern and attempt to read online diagnostics via STEP 7 or TIA Portal.

    Perform a factory reset of the interface module by removing power, setting the address switches to 0, reapplying power briefly, then restoring the correct address and re-downloading the hardware configuration. If the module remains unresponsive, replace it with a new or refurbished unit.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Placeholder

      Siemens Simatic ET200 6ES7131-1BH11-0XB0

      € 267,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Placeholder

      Siemens Simatic S7 6ES7431-0HH00-0AB0

      € 359,00 – € 484,00Price range: € 359,00 through € 484,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Placeholder

      Siemens Simatic ET200 6ES7132-0BH11-0XB0

      € 478,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart