• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6643-5CB00-0ND1 MP277
    Awaiting product image

    Siemens 6AV6643-5CB00-0ND1 MP277

    € 1.097,00

    Reset
    Clear
    SKU: 6AV6643-5CB00-0ND1 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens MP277 (part number 6AV6643-5CB00-0ND1) is a Multi Panel HMI device belonging to the SIMATIC HMI Multi Panel 277 series. It features a 10.4-inch TFT display and is designed for machine-level visualization and operator control in industrial automation environments. This unit is part of Siemens' established SIMATIC HMI portfolio, offering a robust platform for process visualization and operator interaction.

    The 6AV6643-5CB00-0ND1 variant features a 10.4-inch TFT color display with a resolution of 640 x 480 pixels (VGA) and supports touch screen operation. It is equipped with MPI/PROFIBUS DP and Ethernet (PROFINET) communication interfaces, enabling integration with SIMATIC S7 PLCs and other compatible controllers. The panel runs on Windows CE and supports WinCC flexible runtime software, providing a flexible environment for HMI application development. It includes 12 MB user memory for project data and supports USB ports for data transfer and peripheral connectivity.

    The MP277 10" Touch is widely used in manufacturing, automotive, food and beverage, and process industries where reliable machine-level HMI is required. Its compatibility with SIMATIC S7-300 and S7-400 PLCs, as well as third-party controllers via standard protocols, makes it suitable for a broad range of machine control and process monitoring applications. The panel's robust construction and wide operating temperature range make it appropriate for demanding industrial environments.

    Technical Specifications

    Display Size 10.4 inch
    Display Type TFT color
    Display Resolution 640 x 480 pixels (VGA)
    Display Colors 256 colors
    Touch Technology Resistive touch screen
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 25 W
    User Memory 12 MB
    Communication Interface MPI/PROFIBUS DP, Ethernet (PROFINET), USB
    Operating System Windows CE
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC HMI Multi Panel 277

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between HMI panel and PLC. The configured connection to the controller cannot be established or has been interrupted.
    Check MPI/PROFIBUS or Ethernet cable connections and termination resistors. Verify PLC address settings match the HMI project configuration. Ensure the PLC is in RUN mode.
    Event ID: 10001
    Connection to PLC lost during runtime. The HMI panel has detected a timeout on the configured communication channel.
    Inspect physical wiring and connectors. Check network settings and PLC program. Restart both the HMI panel and PLC if the connection is not restored automatically.
    Event ID: 40000
    Project download error. The project could not be transferred to the HMI panel successfully.
    Verify the communication settings in WinCC flexible match the panel configuration. Check USB or Ethernet connection used for transfer. Ensure sufficient free memory on the panel.
    Event ID: 50000
    System memory low. Available runtime memory on the panel is insufficient for the current project.
    Reduce the number of active screens or objects in the HMI project. Archive or delete unnecessary data logs and recipe files from the panel memory.
    Event ID: 70000
    Tag update error. One or more configured tags cannot be read from or written to the PLC.
    Check the tag addresses in the WinCC flexible project against the actual PLC data block structure. Verify the PLC program contains the referenced data areas.
    Event ID: 20000
    Backup/restore error. A backup or restore operation of the panel project or data failed.
    Ensure the USB storage device is properly formatted and has sufficient free space. Retry the backup/restore operation. If the error persists, check the integrity of the storage medium.
    Event ID: 60000
    Screen saver or display error. The display has encountered an issue during operation, such as backlight failure or display driver fault.
    Check the 24 V DC supply voltage at the panel connector. If the backlight has failed, the panel may require servicing or backlight replacement. Restart the panel to attempt recovery.

    Frequently Asked Questions

    What communication interfaces does the MP277 6AV6643-5CB00-0ND1 support?

    The MP277 supports MPI/PROFIBUS DP and Ethernet (PROFINET) interfaces, as well as USB ports for data transfer and peripheral devices. This allows direct connection to SIMATIC S7 PLCs and PROFINET-capable controllers.

    Which software is used to program and configure the MP277?

    The MP277 is configured using Siemens WinCC flexible software. Projects are created on a PC and downloaded to the panel via USB or Ethernet connection.

    Is the MP277 compatible with SIMATIC S7-300 and S7-400 PLCs?

    Yes, the MP277 is fully compatible with SIMATIC S7-300 and S7-400 PLCs via MPI, PROFIBUS DP, or Ethernet connections. It can also communicate with third-party controllers using supported standard protocols.

    What is the input voltage requirement for the MP277?

    The MP277 requires a 24 V DC supply voltage. Ensure the power supply can deliver sufficient current, as the panel consumes up to 25 W.

    What is the front panel protection rating of the MP277?

    The front panel of the MP277 carries an IP65 protection rating, making it suitable for panel mounting in environments where dust and water spray may be present.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the panel power connector. Check for blown internal fuses or a failed backlight. Observe whether the panel emits any startup sounds or LED activity.

    Ensure the 24 V DC supply is within tolerance and properly connected. If the supply is correct but the display remains blank, the backlight or internal power supply may have failed and the panel will require repair or component replacement.

    HMI panel cannot communicate with the PLC

    Verify the MPI/PROFIBUS or Ethernet cable is correctly connected and undamaged. Check that the bus address and communication parameters in the HMI project match the PLC configuration. Use a bus diagnostic tool to check for bus errors.

    Correct any address conflicts or parameter mismatches in the WinCC flexible project. Replace damaged cables or connectors. Ensure termination resistors are correctly placed at both ends of the PROFIBUS segment.

    Touchscreen does not respond or responds inaccurately

    Check for physical damage or contamination on the touch surface. Attempt to recalibrate the touch screen via the panel's system settings menu. Determine whether the issue is consistent across the entire screen or localized to a specific area.

    Clean the touch surface with a soft, dry cloth. Perform a touch screen calibration from the Windows CE control panel. If calibration does not resolve the issue, the touch screen overlay may require replacement.

    Project download fails from WinCC flexible

    Check the USB or Ethernet connection between the engineering PC and the panel. Verify that the correct panel type and firmware version are selected in the WinCC flexible project settings. Check available memory on the panel.

    Ensure the communication interface is correctly configured on both the PC and the panel. Delete unused files from the panel memory to free up space. Update the panel firmware if there is a version mismatch with the WinCC flexible project.

    Panel repeatedly restarts or crashes during runtime

    Check the 24 V DC supply for voltage dips or instability under load. Review the system event log on the panel for specific event IDs. Determine whether the issue occurs with a specific screen or action in the HMI project.

    Stabilize the power supply and ensure adequate current capacity. Simplify complex HMI screens or reduce the number of simultaneous tag updates. If the issue persists, perform a factory reset and reload the project, or return the panel for repair.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart