Siemens 6AV3515-1EB30-1AA0 SIMATIC OP 15
€ 399,00 – € 518,00Price range: € 399,00 through € 518,00
The Siemens 6AV3515-1EB30-1AA0 is an Operator Panel (OP 15) belonging to the SIMATIC HMI family, designed for human-machine interface applications in industrial automation environments. This unit provides a text-based display interface for monitoring and controlling machine processes, and is part of Siemens' classic OP series of operator panels. It is intended for direct integration with Siemens SIMATIC S5 and S7 programmable logic controllers.
The OP 15 features a multi-line LCD text display capable of showing alphanumeric characters and system messages, along with a membrane keypad for operator input. It supports serial communication interfaces including TTY and RS-232/RS-485 for connection to PLCs and other automation devices. The panel is designed for front-panel mounting with a robust housing suited to industrial environments, offering a protection rating of IP65 on the front face. Configuration is performed using Siemens ProTool software, allowing recipe management, alarm logging, and process value display.
The SIMATIC OP 15 is widely used in machine building, manufacturing automation, and process control applications where a compact, reliable text-based operator interface is required. It is commonly found on packaging machinery, conveyor systems, and general-purpose industrial machines where operators need to monitor alarms, adjust setpoints, and navigate process menus. Its compatibility with the SIMATIC S5 and S7 controller families makes it suitable for both legacy system maintenance and retrofit projects.
Technical Specifications
| Display Type | LCD text display |
|---|---|
| Display Lines | 4 lines |
| Characters per Line | 20 characters |
| Input/Operating Voltage | 24 V DC |
| Communication Interface | TTY, RS-232, RS-485 |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP00 |
| Operating Temperature | 0 °C to 50 °C |
| Storage Temperature | -20 °C to 70 °C |
| Relative Humidity | 10 % to 90 % (non-condensing) |
| Mounting | Panel front mounting |
| Series/Product Family | SIMATIC OP 15 |
| PLC Compatibility | SIMATIC S5, SIMATIC S7 |
| Configuration Software | Siemens ProTool |
Common Error Codes & System Events
- System Error 1
- Communication error between the OP 15 and the connected PLC. The panel cannot establish or maintain a connection.
Check the communication cable and connector integrity. Verify the interface settings (baud rate, address) match the PLC configuration. Restart both the panel and PLC. - System Error 2
- Configuration data error or missing project data in the operator panel memory.
Re-download the project configuration from ProTool to the OP 15. Verify the transfer cable and COM port settings are correct. - System Error 3
- Internal memory fault detected during self-test at startup.
Perform a master reset of the panel. If the fault persists, the internal memory or hardware may be defective and the unit should be repaired or replaced. - Alarm: PLC Connection Lost
- The OP 15 has lost communication with the PLC during operation.
Check the serial communication cable for damage or loose connections. Verify PLC is powered and running. Check baud rate and station address configuration on both devices. - Alarm: Recipe Error
- An error occurred during recipe read or write operation.
Verify the recipe configuration in ProTool. Check that the PLC data blocks referenced by the recipe exist and are correctly addressed. - Alarm: Watchdog Timeout
- The panel's internal watchdog timer has triggered, indicating a system hang or processing error.
Cycle power to the OP 15. If the fault recurs frequently, check the power supply voltage stability and inspect for hardware faults. - Transfer Mode Active
- The panel is in transfer mode awaiting a project download and will not display the normal operator interface.
Initiate a project download from ProTool, or press the appropriate key combination to exit transfer mode and return to normal operation.
Frequently Asked Questions
What PLC systems is the 6AV3515-1EB30-1AA0 compatible with?
The SIMATIC OP 15 is compatible with Siemens SIMATIC S5 and S7 PLC families via serial communication interfaces including TTY and RS-232/RS-485.
What software is used to configure the OP 15?
The OP 15 is configured using Siemens ProTool configuration software, which allows creation of screens, alarm messages, recipes, and process value displays.
What is the supply voltage for this operator panel?
The 6AV3515-1EB30-1AA0 operates on a 24 V DC supply voltage.
What is the front panel protection rating of the OP 15?
The front face of the OP 15 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets.
Can the OP 15 be used as a replacement in an existing SIMATIC S5 installation?
Yes, the OP 15 supports the SIMATIC S5 communication protocol and is suitable for use in legacy S5 installations, making it a viable replacement or spare part for existing systems.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the panel power connector using a multimeter. Verify the power supply is within tolerance and the connector is fully seated.
Restore the supply voltage to the correct 24 V DC level. If voltage is correct but the display remains blank, the internal power supply or display unit may be faulty and the panel should be inspected for hardware damage.
Panel shows communication error or cannot connect to PLC
Verify the serial communication cable wiring between the OP 15 and the PLC. Check that the baud rate, parity, and station address configured in ProTool match the PLC interface settings.
Correct any wiring faults or connector issues. Align the communication parameters on both the panel and PLC. Replace the communication cable if damaged.
Project download from ProTool fails or times out
Check the PC-to-panel transfer cable connection and the COM port assignment in ProTool. Ensure the panel is in transfer mode before initiating the download.
Place the panel in transfer mode using the correct key combination. Verify the correct COM port is selected in ProTool and that no other application is using the port. Try a different transfer cable if the issue persists.
Alarm messages are not displayed correctly or are missing
Review the alarm configuration in the ProTool project. Verify that the PLC data bits mapped to alarm triggers are correctly addressed and that the project has been successfully downloaded to the panel.
Correct the alarm bit addressing in ProTool and re-download the project. Confirm PLC program is setting the correct alarm bits as expected.
Panel restarts unexpectedly during operation
Measure the 24 V DC supply voltage under load to check for voltage dips or instability. Inspect the power supply unit and wiring for loose connections or undersized cabling.
Stabilize the power supply by ensuring adequate current capacity and secure wiring connections. Replace the power supply unit if voltage instability is confirmed.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page