Siemens 6AV7456-2TB00-0BS1 SIMATIC IPC477C
€ 859,00
The Siemens 6AV7456-2TB00-0BS1 is a panel PC belonging to the SIMATIC IPC477C series, manufactured by Siemens as part of its industrial computing and HMI portfolio. This unit is a 15-inch industrial panel PC designed for demanding automation environments, combining HMI functionality with PC-based control in a single compact device. It is built for panel mounting and integrates seamlessly into Siemens automation architectures.
The IPC477C features a 15-inch TFT display with a resistive touch screen and a high-brightness backlight suitable for industrial environments. It is equipped with an Intel Core processor, DDR3 RAM, and solid-state or hard disk drive storage options, providing robust computing performance for SCADA, visualization, and process control applications. The unit supports multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces, and is compatible with PROFINET and standard industrial protocols. The enclosure is rated to IP65 on the front panel, protecting against dust and water ingress.
The SIMATIC IPC477C is widely deployed in manufacturing automation, process industries, machine tool control, and plant-level visualization tasks. Its fanless or actively cooled design options make it suitable for environments where reliability and low maintenance are critical. The device is commonly used with Siemens WinCC, WinCC flexible, and other SCADA software platforms in automotive, food and beverage, chemical, and discrete manufacturing industries.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Type | TFT LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Communication Interfaces | 2x Ethernet RJ45, 4x USB, 1x RS-232 |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC IPC477C |
| Certifications | CE, UL, cULus |
| Bus System Compatibility | PROFINET |
| Operating System | Windows Embedded Standard 7 / Windows 7 |
Common Error Codes & System Events
- Event ID: 1000
- Application error – a software application on the panel PC has crashed or terminated unexpectedly.
Check Windows Event Viewer for details. Restart the application or reinstall the affected software. Ensure the operating system and drivers are up to date. - Event ID: 6008
- Unexpected shutdown – the system was not shut down cleanly, indicating a possible power loss or system crash.
Check the 24 V DC power supply for stability and correct voltage. Inspect for overtemperature conditions. Review event logs for prior errors. - BIOS POST Error
- Hardware fault detected during Power-On Self-Test, indicating a memory, CPU, or hardware component failure.
Reseat RAM modules and check all internal connections. If the error persists, replace the faulty hardware component or contact Siemens service. - Watchdog Timeout
- The system watchdog has triggered a reset due to the operating system or application becoming unresponsive.
Investigate software causing the hang. Check CPU and memory utilization. Update or reinstall the application. Verify cooling is adequate. - Fan Failure Warning
- Cooling fan has failed or is operating below the minimum required speed, risking overtemperature.
Replace the defective fan. Ensure ventilation slots are not blocked. Check ambient temperature is within specification. - Overtemperature Warning
- Internal temperature has exceeded the permissible operating limit, triggering a thermal protection event.
Check ambient temperature and ensure it is within 0–50 °C. Clean air filters and ventilation openings. Verify fan operation. - Hard Disk Error
- The storage drive has reported a read/write error or S.M.A.R.T. failure, indicating potential drive degradation.
Run a disk diagnostic utility. Back up data immediately. Replace the hard disk or SSD if S.M.A.R.T. errors are confirmed. - Network Link Down
- Ethernet interface has lost link, indicating a cable fault, switch issue, or NIC failure.
Check Ethernet cable and switch port. Verify network adapter settings in Device Manager. Replace cable or NIC if hardware fault is confirmed.
Frequently Asked Questions
What is the supply voltage for the 6AV7456-2TB00-0BS1?
The SIMATIC IPC477C operates on a 24 V DC power supply. Ensure the supply is stable and within the specified tolerance range.
What is the front panel protection rating of this panel PC?
The front panel of the 6AV7456-2TB00-0BS1 is rated IP65, providing protection against dust and low-pressure water jets.
Which operating systems are supported by the SIMATIC IPC477C?
The IPC477C supports Windows Embedded Standard 7 and Windows 7 Professional. It is compatible with Siemens WinCC and WinCC flexible visualization software.
What communication interfaces are available on this unit?
The unit provides two Ethernet RJ45 ports, four USB ports, and one RS-232 serial interface, supporting PROFINET and standard TCP/IP communication.
Is the display on this panel PC touch-enabled?
Yes, the 6AV7456-2TB00-0BS1 features a 15-inch resistive touchscreen, suitable for operation with gloves or in industrial environments.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify the power LED status. Measure voltage at the internal power supply output rails.
Restore correct supply voltage if out of range. Replace the internal power supply if it has failed. If the display backlight has failed, replace the backlight inverter or the display assembly.
Touchscreen does not respond or registers incorrect touch positions
Check if the touch controller is recognized in Windows Device Manager. Verify that the resistive touch surface is clean and undamaged. Run the touch calibration utility.
Recalibrate the touchscreen using the Windows calibration tool. Update or reinstall the touch controller driver. If the touch surface is physically damaged, replace the touch panel assembly.
Panel PC fails to boot and shows BIOS error or blank screen with no POST
Reseat RAM modules and check all internal connectors. Attempt to boot with minimal hardware. Check for BIOS POST error codes displayed on screen.
Reseat or replace RAM modules. Clear CMOS by removing the BIOS battery briefly. If the motherboard is faulty, replace the main board or return the unit for repair.
System frequently restarts or crashes unexpectedly
Check Windows Event Viewer for critical errors and watchdog events. Monitor CPU temperature using a diagnostic tool. Verify the 24 V DC supply is stable under load.
Ensure adequate ventilation and clean any blocked air filters. Stabilize the power supply. Update drivers and operating system patches. If hardware faults are confirmed, replace the defective component.
Ethernet communication is not established
Check the physical Ethernet cable and switch port LEDs. Verify IP address configuration in Windows Network Settings. Check Device Manager for NIC driver errors.
Replace the Ethernet cable if damaged. Reinstall the network adapter driver. Configure the correct IP address and subnet mask. If the NIC hardware has failed, replace the network interface card or the main board.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page