Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13
The Siemens 6AV6640-0CA01-0AX0 is the OP 73micro operator panel, part of the SIMATIC HMI Micro Panel family. It is a compact text-based operator panel designed for straightforward machine-level operator control and monitoring tasks. This unit provides a cost-effective solution for applications requiring basic HMI functionality without graphical display requirements.
The OP 73micro features a 3-line text display capable of showing alphanumeric characters, with a membrane keypad for operator input. It communicates via a PPI (Point-to-Point Interface) or MPI (Multi-Point Interface) connection, making it directly compatible with SIMATIC S7-200 PLCs. The panel operates on a 24 V DC supply and is designed for panel front mounting with an IP65 protection rating on the front face, suitable for industrial environments.
The OP 73micro is widely used in small-scale machine automation, conveyor systems, packaging machinery, and general-purpose industrial equipment where a simple, reliable operator interface is required. Its compact dimensions and low cost make it particularly suitable for OEM machine builders who need a basic text display and keypad interface integrated into control panels. It is compatible with STEP 7-Micro/WIN and WinCC flexible Micro configuration software.
Technical Specifications
| Display Type | Text display, 3 lines |
|---|---|
| Characters per Line | 12 characters |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | 2.5 W |
| Communication Interface | PPI / MPI (RS-485) |
| PLC Compatibility | SIMATIC S7-200 |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| Mounting | Panel front mounting |
| Certifications | CE, UL |
| Series/Product Family | SIMATIC HMI Micro Panel |
Common System Event Codes
- System Event 10000
- Communication error between the HMI panel and the connected PLC. The panel cannot establish or maintain a connection.
Check the RS-485 cable connections and termination resistors. Verify the PLC address and communication parameters match the HMI configuration. Ensure the PLC is powered and running. - System Event 10001
- PLC connection timeout. The panel has lost communication with the PLC during operation.
Inspect the communication cable for damage or loose connectors. Verify PLC is in RUN mode. Check for address conflicts on the MPI/PPI network. - System Event 20000
- Configuration download error. The project could not be transferred to the panel.
Verify the transfer cable is correctly connected. Check that the correct COM port and transfer settings are selected in WinCC flexible Micro. Restart the panel in transfer mode. - System Event 40000
- Tag read error. The HMI is unable to read a configured tag from the PLC.
Verify the tag address in the HMI project matches the actual PLC variable address. Check that the PLC program contains the referenced data block or variable. - System Event 40001
- Tag write error. The HMI is unable to write a value to the configured PLC tag.
Check that the target PLC address is writable and not write-protected. Verify the data type of the tag in the HMI project matches the PLC variable type. - System Event 50000
- Internal device error. A hardware or firmware fault has been detected within the panel.
Perform a power cycle of the panel. If the error persists, reload the HMI project. If the fault continues, the panel may require replacement or factory service.
Frequently Asked Questions
Which PLCs are compatible with the OP 73micro?
The OP 73micro is designed for use with SIMATIC S7-200 PLCs via PPI or MPI communication. It is not natively compatible with S7-300 or S7-400 PLCs.
What software is used to configure the OP 73micro?
The OP 73micro is configured using WinCC flexible Micro or STEP 7-Micro/WIN software. Projects are transferred to the panel via a PC/PPI cable.
What is the supply voltage for the 6AV6640-0CA01-0AX0?
The panel requires a 24 V DC supply voltage for operation.
What is the front panel protection rating of the OP 73micro?
The front face of the OP 73micro carries an IP65 protection rating, making it resistant to dust and water jets, suitable for industrial panel mounting.
Can the OP 73micro display graphical content?
No, the OP 73micro is a text-only display panel capable of showing alphanumeric characters across 3 lines. It does not support graphical or bitmap display content.
Troubleshooting
Panel display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Measure voltage between the L+ and M terminals to confirm correct supply level.
Ensure the power supply is providing a stable 24 V DC within the specified tolerance. Check wiring connections and replace any blown fuses in the supply circuit. If supply is confirmed correct, the panel's internal power circuitry may be faulty and the unit may require replacement.
No communication with S7-200 PLC
Verify the PC/PPI or MPI cable is correctly connected between the panel and the PLC. Check that the baud rate and station address configured in the HMI project match the PLC settings.
Replace or reseat the communication cable. Correct any address or baud rate mismatches in the WinCC flexible Micro project and re-download the configuration to the panel. Ensure termination resistors are correctly set on the RS-485 network.
HMI project cannot be transferred to the panel
Confirm the panel is in transfer mode. Check the PC COM port settings and that the correct transfer cable type is selected in the configuration software.
Restart the panel and hold the appropriate key combination to enter transfer mode. Verify the COM port is not in use by another application. Use the correct PC/PPI cable and ensure the baud rate in the transfer settings matches the cable specification.
Tags showing incorrect or no values on the display
Compare the tag addresses configured in the HMI project against the actual variable addresses in the S7-200 PLC program. Check for data type mismatches.
Correct any address discrepancies in the WinCC flexible Micro project. Ensure the PLC program is writing valid data to the referenced addresses. Re-download the corrected project to the panel.
Membrane keypad buttons not responding
Inspect the keypad membrane for physical damage, contamination, or deformation. Check if the issue is with all keys or specific keys only.
Clean the keypad surface with a dry cloth to remove any contamination. If individual keys are unresponsive due to membrane damage, the front panel membrane assembly will need to be replaced. Contact a qualified repair technician for membrane replacement.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page